메뉴 건너뛰기




Volumn 11, Issue SUPPL. 2, 2004, Pages

A decade of thoracic endografting: Planning the next 10 years. . .

Author keywords

Aortic dissection; Endovascular repair; Stent graft; Thoracic aorta; Thoracic aortic aneurysm

Indexed keywords

ANEURYSM; AORTA ARCH; AORTA DISSECTION; AORTA INJURY; ENDOLEAK; ENDOVASCULAR SURGERY; FISTULA; HEART GRAFT; HUMAN; MEDICAL PRACTICE; MYCOTIC ANEURYSM; PRIORITY JOURNAL; REVIEW; SAFETY; THORACIC AORTA ANEURYSM;

EID: 12144267488     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1177/15266028040110s610     Document Type: Review
Times cited : (9)

References (28)
  • 1
    • 0024119126 scopus 로고
    • A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm
    • Volodos NL, Karpovich IP, Shekhanin VE, et al. A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm [in Russian]. Grudn Khir. 1988;6:84-86.
    • (1988) Grudn Khir , vol.6 , pp. 84-86
    • Volodos, N.L.1    Karpovich, I.P.2    Shekhanin, V.E.3
  • 2
    • 0028631110 scopus 로고
    • Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms
    • Dake MD, Miller DC, Semba CP, et al. Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med. 1994;331:1729-1734.
    • (1994) N Engl J Med , vol.331 , pp. 1729-1734
    • Dake, M.D.1    Miller, D.C.2    Semba, C.P.3
  • 3
    • 0031739777 scopus 로고    scopus 로고
    • The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta
    • Dake MD, Miller DC, Mitchell RS, et al. The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg. 1998;116:689-704.
    • (1998) J Thorac Cardiovasc Surg , vol.116 , pp. 689-704
    • Dake, M.D.1    Miller, D.C.2    Mitchell, R.S.3
  • 4
    • 0033978433 scopus 로고    scopus 로고
    • Endovascular repair of descending thoracic aortic aneurysms: An early experience with intermediate-term follow-up
    • Greenberg RK, Resch T, Nyman U, et al. Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up. J Vasc Surg. 2000;31:147-156.
    • (2000) J Vasc Surg , vol.31 , pp. 147-156
    • Greenberg, R.K.1    Resch, T.2    Nyman, U.3
  • 5
    • 10744231885 scopus 로고    scopus 로고
    • Challenges of endovascular tube graft repair of thoracic aortic aneurysm: Midterm follow-up and lessons learned
    • Ellozy SH, Carroccio A, Minor M, et al. Challenges of endovascular tube graft repair of thoracic aortic aneurysm: midterm follow-up and lessons learned. J Vasc Surg. 2003;38:676-683.
    • (2003) J Vasc Surg , vol.38 , pp. 676-683
    • Ellozy, S.H.1    Carroccio, A.2    Minor, M.3
  • 6
    • 85045129683 scopus 로고    scopus 로고
    • Endovascular treatment of thoracic aortic aneurysms: Results of the phase II multicenter trial of the Gore TAG thoracic endoprosthesis
    • Anaheim, California, USA
    • Makaroun S, Dillavou E, Kee S, et al. Endovascular treatment of thoracic aortic aneurysms: results of the phase II multicenter trial of the Gore TAG thoracic endoprosthesis. Presented at the annual meeting of the Society for Vascular Surgery June 2-5, 2004; Anaheim, California, USA.
    • (2004) Annual Meeting of the Society for Vascular Surgery June 2-5
    • Makaroun, S.1    Dillavou, E.2    Kee, S.3
  • 7
    • 0035653526 scopus 로고    scopus 로고
    • Risk of spinal cord ischemia after endograft repair of thoracic aortic aneurysms
    • Gravereaux E, Faries PL, Burks JA, et al. Risk of spinal cord ischemia after endograft repair of thoracic aortic aneurysms. J Vasc Surg. 2001:34:997-1003.
    • (2001) J Vasc Surg , vol.34 , pp. 997-1003
    • Gravereaux, E.1    Faries, P.L.2    Burks, J.A.3
  • 8
    • 0036593014 scopus 로고    scopus 로고
    • Evolving experience with thoracic aortic stent graft repair
    • Cambria RP, Brewster DC, Lauterbach SR, et al. Evolving experience with thoracic aortic stent graft repair. J Vasc Surg. 2002;35:1129-1136.
    • (2002) J Vasc Surg , vol.35 , pp. 1129-1136
    • Cambria, R.P.1    Brewster, D.C.2    Lauterbach, S.R.3
  • 9
    • 0037001001 scopus 로고    scopus 로고
    • Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience
    • Criado FJ, Clark NS, Barnatan MF. Stent graft repair in the aortic arch and descending thoracic aorta: a 4-year experience. J Vasc Surg. 2002;36:1121-1128.
    • (2002) J Vasc Surg , vol.36 , pp. 1121-1128
    • Criado, F.J.1    Clark, N.S.2    Barnatan, M.F.3
  • 10
    • 10744223716 scopus 로고    scopus 로고
    • Stent-graft placement in atherosclerotic descending thoracic aortic aneurysms: Midterm results
    • Czerny M, Cejna M, Hutschala D, et al. Stent-graft placement in atherosclerotic descending thoracic aortic aneurysms: midterm results. J Endovasc Ther. 2004;11:26-32.
    • (2004) J Endovasc Ther , vol.11 , pp. 26-32
    • Czerny, M.1    Cejna, M.2    Hutschala, D.3
  • 13
    • 0021260746 scopus 로고
    • Independent determinants of operative mortality for patients with aortic dissections
    • Miller DC, Mitchell RS, Oyer PE, et al. Independent determinants of operative mortality for patients with aortic dissections. Circulation. 1984;70:I153-164.
    • (1984) Circulation , vol.70
    • Miller, D.C.1    Mitchell, R.S.2    Oyer, P.E.3
  • 14
    • 0023687319 scopus 로고
    • Aortic dissection and dissecting aortic aneurysms
    • Crawford ES, Svensson LG, Coselli JS, et al. Aortic dissection and dissecting aortic aneurysms. Ann Surg. 1988;208:254-273.
    • (1988) Ann Surg , vol.208 , pp. 254-273
    • Crawford, E.S.1    Svensson, L.G.2    Coselli, J.S.3
  • 15
    • 0023848099 scopus 로고
    • Vascular complications associated with spontaneous aortic dissection
    • Cambria RP, Brewster DC, Gertler J, et al. Vascular complications associated with spontaneous aortic dissection. J Vasc Surg. 1988;7:199-209.
    • (1988) J Vasc Surg , vol.7 , pp. 199-209
    • Cambria, R.P.1    Brewster, D.C.2    Gertler, J.3
  • 16
    • 0033586995 scopus 로고    scopus 로고
    • Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement
    • Nienaber CA, Fattori R, Lund G, et al. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med. 1999;340:1539-1545.
    • (1999) N Engl J Med , vol.340 , pp. 1539-1545
    • Nienaber, C.A.1    Fattori, R.2    Lund, G.3
  • 17
    • 0033586990 scopus 로고    scopus 로고
    • Endovascular stent-graft placement for the treatment of acute aortic dissection
    • Dake MD, Kato N, Mitchell RS, et al. Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med. 1999;340:1546-1552.
    • (1999) N Engl J Med , vol.340 , pp. 1546-1552
    • Dake, M.D.1    Kato, N.2    Mitchell, R.S.3
  • 18
    • 0033744060 scopus 로고    scopus 로고
    • Treatment of Stanford type B aortic dissection with stent-grafts: Preliminary results
    • Czermak BV, Waldenberger P, Fraedrich G, et al. Treatment of Stanford type B aortic dissection with stent-grafts: preliminary results. Radiology. 2000;217:544-50.
    • (2000) Radiology , vol.217 , pp. 544-550
    • Czermak, B.V.1    Waldenberger, P.2    Fraedrich, G.3
  • 19
    • 0035122698 scopus 로고    scopus 로고
    • Endovascular stent-graft repair of acute thoracic aortic dissection-early clinical experiences
    • Tiesenhausen K, Amann W, Koch G, et al. Endovascular stent-graft repair of acute thoracic aortic dissection-early clinical experiences. Thorac Cardiovasc Surg. 2001;49:16-20.
    • (2001) Thorac Cardiovasc Surg , vol.49 , pp. 16-20
    • Tiesenhausen, K.1    Amann, W.2    Koch, G.3
  • 20
    • 0037167683 scopus 로고    scopus 로고
    • Transluminal stent-graft placements for the treatments of acute onset and chronic aortic dissections
    • Shimono T, Kato N, Yasuda F, et al. Transluminal stent-graft placements for the treatments of acute onset and chronic aortic dissections. Circulation. 2002;106(12 Suppl 1):I241-I247.
    • (2002) Circulation , vol.106 , Issue.12 SUPPL. 1
    • Shimono, T.1    Kato, N.2    Yasuda, F.3
  • 21
    • 0141645380 scopus 로고    scopus 로고
    • Emergency stent-graft placement in thoracic aortic dissection and evolving rupture
    • Nienaber CA, Ince H, Weber F, et al. Emergency stent-graft placement in thoracic aortic dissection and evolving rupture. J Card Surg. 2003;18:464-470.
    • (2003) J Card Surg , vol.18 , pp. 464-470
    • Nienaber, C.A.1    Ince, H.2    Weber, F.3
  • 22
    • 0035458309 scopus 로고    scopus 로고
    • Aneurysmal degeneration of the aorta after stent-graft repair of acute aortic dissection
    • Kato N, Hirano T, Kawaguchi T, et al. Aneurysmal degeneration of the aorta after stent-graft repair of acute aortic dissection. J Vasc Surg. 2001;33:513-518.
    • (2001) J Vasc Surg , vol.33 , pp. 513-518
    • Kato, N.1    Hirano, T.2    Kawaguchi, T.3
  • 23
    • 0019276709 scopus 로고
    • Current status of medical therapy of acute dissecting aneurysms of the aorta
    • Wheat MW Jr. Current status of medical therapy of acute dissecting aneurysms of the aorta. World J Surg. 1980;4:563-569.
    • (1980) World J Surg , vol.4 , pp. 563-569
    • Wheat Jr., M.W.1
  • 25
    • 4444256793 scopus 로고    scopus 로고
    • Stent-graft placement combined with percutaneous fenestration for the treatment of aortic dissection in a patient at risk of developing renal ischemia
    • Kato N, Hirano T, Ishida M, et al. Stent-graft placement combined with percutaneous fenestration for the treatment of aortic dissection in a patient at risk of developing renal ischemia. Ann Thorac Surg. 2004;78:1072-1075.
    • (2004) Ann Thorac Surg , vol.78 , pp. 1072-1075
    • Kato, N.1    Hirano, T.2    Ishida, M.3
  • 26
    • 0034931828 scopus 로고    scopus 로고
    • Treatment of chronic aortic dissection by transluminal endovascular stent-graft placement: Preliminary results
    • Kato N, Hirano T, Shimono T, et al. Treatment of chronic aortic dissection by transluminal endovascular stent-graft placement: preliminary results. J Vasc Interv Radiol. 2001;12:835-840.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 835-840
    • Kato, N.1    Hirano, T.2    Shimono, T.3
  • 27
    • 0028207013 scopus 로고
    • Significance of distal false lumen after type A dissection repair
    • Ergin MA, Phillips RA, Galla JD, et al. Significance of distal false lumen after type A dissection repair. Ann Thorac Surg. 1994;57:820-824.
    • (1994) Ann Thorac Surg , vol.57 , pp. 820-824
    • Ergin, M.A.1    Phillips, R.A.2    Galla, J.D.3
  • 28
    • 0019444406 scopus 로고
    • Clotted false lumen: Reappraisal of indications for medical management of acute aortic dissection
    • Sanderson CJ, Rich S, Beere PA, et al. Clotted false lumen: reappraisal of indications for medical management of acute aortic dissection. Thorax. 1981;36:194-199.
    • (1981) Thorax , vol.36 , pp. 194-199
    • Sanderson, C.J.1    Rich, S.2    Beere, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.