메뉴 건너뛰기




Volumn 53, Issue 1, 2005, Pages 231-236

Calibration of gradient propagation delays for accurate two-dimensional radiofrequency pulses

Author keywords

2D RF pulses; Calibration; Gradient delays; Multidimensional selective excitation; Propagation delays

Indexed keywords

SPACE FLIGHT;

EID: 12144251360     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20308     Document Type: Article
Times cited : (13)

References (8)
  • 1
    • 0030924013 scopus 로고    scopus 로고
    • Quantification and reduction of ghosting artifacts in interleaved echo planar imaging
    • Reeder SB, Atalar E, Bolster BD, McVeigh ER. Quantification and reduction of ghosting artifacts in interleaved echo planar imaging. Magn Reson Med 1997;38:429-439.
    • (1997) Magn Reson Med , vol.38 , pp. 429-439
    • Reeder, S.B.1    Atalar, E.2    Bolster, B.D.3    McVeigh, E.R.4
  • 3
    • 0037925300 scopus 로고    scopus 로고
    • Centering the projection reconstruction trajectory: Reducing gradient delay errors
    • Peters DC, Derbyshire JA, McVeigh ER. Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 2003;50:1-6.
    • (2003) Magn Reson Med , vol.50 , pp. 1-6
    • Peters, D.C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 4
    • 0029121371 scopus 로고
    • Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories
    • Takahashi A, Peters T. Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories. Magn Reson Med 1995;34:446-456.
    • (1995) Magn Reson Med , vol.34 , pp. 446-456
    • Takahashi, A.1    Peters, T.2
  • 5
    • 0037764001 scopus 로고    scopus 로고
    • Selective arterial spin labeling (SASL): Perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses
    • Davies NP, Jezzard P. Selective arterial spin labeling (SASL): perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses. Magn Reson Med 2003;49:1133-1142.
    • (2003) Magn Reson Med , vol.49 , pp. 1133-1142
    • Davies, N.P.1    Jezzard, P.2
  • 6
    • 45149145242 scopus 로고
    • A k-space analysis of small tip-angle excitation
    • Pauly J, Nishimura D, Macovski A. A k-space analysis of small tip-angle excitation. J Magn Reson 1989;81:43-56.
    • (1989) J Magn Reson , vol.81 , pp. 43-56
    • Pauly, J.1    Nishimura, D.2    Macovski, A.3
  • 7
    • 0031948923 scopus 로고    scopus 로고
    • Effects of gradient anisotropy in MRI
    • Aldefeld B, Bornert P. Effects of gradient anisotropy in MRI. Magn Reson Med 1998;39:606-614.
    • (1998) Magn Reson Med , vol.39 , pp. 606-614
    • Aldefeld, B.1    Bornert, P.2
  • 8
    • 0032059889 scopus 로고    scopus 로고
    • Simple correction method for k-space trajectory deviations in MRI
    • Duyn JH, Yang Y, Frank JA, van der Veen JW. Simple correction method for k-space trajectory deviations in MRI. J Magn Reson 1998; 132:150-153.
    • (1998) J Magn Reson , vol.132 , pp. 150-153
    • Duyn, J.H.1    Yang, Y.2    Frank, J.A.3    Van Der Veen, J.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.