메뉴 건너뛰기




Volumn 5, Issue 1, 2004, Pages 218-222

Efficient and compact high-power mid-IR (∼3 μm) lasers for surgical applications

Author keywords

Ablation; Ear surgery; Erbium; Fiber laser; Hearing; Mid IR; Middle ear; Otosclerosis; Surgery; Tissue; ZBLAN

Indexed keywords

EAR SURGERY; MID-IR; MIDDLE EAR; OTOSCLEROSIS; ZBLAN;

EID: 12144251101     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.561720     Document Type: Conference Paper
Times cited : (14)

References (15)
  • 1
    • 84860075597 scopus 로고    scopus 로고
    • Shore Laser Center (www.shorelaser.com)
  • 3
    • 0030070851 scopus 로고    scopus 로고
    • Temperature and pressure effects during erbium laser stapedotomy
    • H. Pratisto et. al., "Temperature and pressure effects during Erbium Laser Stapedotomy", Lasers in Surgery and Medicine, 18, pp. 100-108, (1996)
    • (1996) Lasers in Surgery and Medicine , vol.18 , pp. 100-108
    • Pratisto, H.1
  • 4
    • 0030829315 scopus 로고    scopus 로고
    • The Er:YAG laser in ear surgery: First clinical results
    • D. Nagel, et. al., "The Er:YAG Laser in Ear Surgery: First Clinical Results", Lasers in Surgery and Medicine, 21, pp. 79-87, (1997)
    • (1997) Lasers in Surgery and Medicine , vol.21 , pp. 79-87
    • Nagel, D.1
  • 5
    • 2442764662 scopus 로고    scopus 로고
    • Advantages and dangers of erbium laser application in stapedotomy
    • R. Hausler, et. al., "Advantages and dangers of Erbium Laser application in Stapedotomy", Acta Otolaryngol, 119, pp. 207-213, (1999)
    • (1999) Acta Otolaryngol , vol.119 , pp. 207-213
    • Hausler, R.1
  • 6
    • 0030963710 scopus 로고    scopus 로고
    • Effects of pulsed laser systems on stapes footplate
    • S. Jovanovic, et. al., "Effects of Pulsed Laser Systems on Stapes Footplate", Lasers in Surgery and Medicine, 21, pp. 341-350, (1997)
    • (1997) Lasers in Surgery and Medicine , vol.21 , pp. 341-350
    • Jovanovic, S.1
  • 7
    • 0033008093 scopus 로고    scopus 로고
    • Clinical and histologic evaluation of six erbium:YAG lasers for cutaneous resurfacing
    • T.S. Alster, "Clinical and Histologic Evaluation of Six Erbium:YAG Lasers for Cutaneous Resurfacing", Lasers in Surgery and Medicine, 24, pp. 87-92, (1999)
    • (1999) Lasers in Surgery and Medicine , vol.24 , pp. 87-92
    • Alster, T.S.1
  • 9
    • 0141595159 scopus 로고    scopus 로고
    • In Vivo effects of an Er:YAG lasers, an ultrasonic systems and scaling and root planing on the biocompatibility of periodontally diseased root surfaces in cultures of human PDL fibroblasts
    • Schwarz "In Vivo Effects of an Er:YAG Lasers, an Ultrasonic Systems and Scaling and Root Planing on the Biocompatibility of Periodontally Diseased Root Surfaces in Cultures of Human PDL Fibroblasts", Lasers in Surgery and Medicine, 33, pp. 140-147, (2003)
    • (2003) Lasers in Surgery and Medicine , vol.33 , pp. 140-147
    • Schwarz1
  • 10
    • 4444275502 scopus 로고    scopus 로고
    • Etch rate and spectroscopic ablation studies of Er:YAG laser-irradiated dentine
    • S.R. Farrar, DC Attril, MR Dickinson, TA King, and AS Blinkhorn, "Etch rate and spectroscopic ablation studies of Er:YAG laser-irradiated dentine," Applied Optics, 36, pp. 5641-5646, (1997).
    • (1997) Applied Optics , vol.36 , pp. 5641-5646
    • Farrar, S.R.1    Attril, D.C.2    Dickinson, M.R.3    King, T.A.4    Blinkhorn, A.S.5
  • 11
    • 0030002927 scopus 로고    scopus 로고
    • Erbium laser ablation of dental hard tissue: Effect of water cooling
    • Steven et. al., "Erbium Laser Ablation of Dental Hard Tissue: Effect of Water Cooling", Lasers in Surgery and Medicine, 18, pp. 294-300, (1996)
    • (1996) Lasers in Surgery and Medicine , vol.18 , pp. 294-300
    • Steven1
  • 12
    • 0035521107 scopus 로고    scopus 로고
    • Quantification and modeling of the dynamic changes in the absorption coefficient of water at 2.94 μm
    • R.K. Shori, et. al., "Quantification and modeling of the dynamic changes in the absorption coefficient of water at 2.94 μm", IEEE j. sel. Topics in quantum electronics, 7, pp. 959-970, (2001)
    • (2001) IEEE J. Sel. Topics in Quantum Electronics , vol.7 , pp. 959-970
    • Shori, R.K.1
  • 13
    • 84860082507 scopus 로고    scopus 로고
    • Achievement of over 3.5 watts output power from a 3 μm Er:ZBLAN fiber laser
    • to be published
    • J. Tafoya, J. Pierce, R.K. Jain, "Achievement of over 3.5 watts output power from a 3 μm Er:ZBLAN fiber laser", to be published, Optics Express, (2004)
    • (2004) Optics Express
    • Tafoya, J.1    Pierce, J.2    Jain, R.K.3
  • 14
    • 0036221327 scopus 로고    scopus 로고
    • Diode-pumped fiber lasers: A new clinical tool?
    • S. D. Jackson and A. Lauto, "Diode-pumped fiber lasers: a new clinical tool?", Lasers in surgery and medicine 30, pp. 184-190, (2002)
    • (2002) Lasers in Surgery and Medicine , vol.30 , pp. 184-190
    • Jackson, S.D.1    Lauto, A.2
  • 15
    • 0028675117 scopus 로고
    • Scanning electron microscopy of otic capsule and calvarial bone ablated by a holmium:YAG laser
    • Wong, B.J.F., Liaw, L-H.L., Neev, J., Berns, M.W. "Scanning Electron Microscopy of Otic Capsule and Calvarial Bone Ablated by a Holmium:YAG Laser", Lasers in Medical Science, 9, pp. 249-260, (1994)
    • (1994) Lasers in Medical Science , vol.9 , pp. 249-260
    • Wong, B.J.F.1    Liaw, L.-H.L.2    Neev, J.3    Berns, M.W.4