메뉴 건너뛰기




Volumn 33, Issue 1, 2005, Pages 65-71

Grey-scale reversed radiographic display in the detection of approximal caries

Author keywords

Dental; Dental caries; Diagnostic systems; Digital radiography; Image processing; ROC curve

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; CALCULATION; CONTROLLED STUDY; DENTAL CARIES; DENTIN; DIGITAL RADIOGRAPHY; HISTOLOGY; HUMAN; HUMAN TISSUE; IMAGE DISPLAY; ROC CURVE; TOOTH RADIOGRAPHY;

EID: 11844304082     PISSN: 03005712     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jdent.2004.08.003     Document Type: Article
Times cited : (23)

References (29)
  • 1
    • 0023446620 scopus 로고
    • Effective presentation of medical images on an electronic display station
    • S. Pizer, R. Johnston, D. Rogers, and D. Beard Effective presentation of medical images on an electronic display station Radiographics 7 1987 1267 1274
    • (1987) Radiographics , vol.7 , pp. 1267-1274
    • Pizer, S.1    Johnston, R.2    Rogers, D.3    Beard, D.4
  • 2
    • 0031260636 scopus 로고    scopus 로고
    • A brief review of human perception factors in digital displays for picture archiving and communications systems
    • J. Wang, and S. Langer A brief review of human perception factors in digital displays for picture archiving and communications systems Journal of Digital Imaging 10 1997 158 168
    • (1997) Journal of Digital Imaging , vol.10 , pp. 158-168
    • Wang, J.1    Langer, S.2
  • 4
    • 0034164585 scopus 로고    scopus 로고
    • Digital imaging for dental caries
    • A. Wenzel Digital imaging for dental caries Dental Clinics of North America 44 2000 319 338 vi
    • (2000) Dental Clinics of North America , vol.44 , pp. 319-338
    • Wenzel, A.1
  • 5
    • 0035344310 scopus 로고    scopus 로고
    • Conventional, digital and contrast-enhanced bitewing radiographs in the decision to restore approximal carious lesions
    • R. Haak, M.J. Wicht, and M.J. Noack Conventional, digital and contrast-enhanced bitewing radiographs in the decision to restore approximal carious lesions Caries Research 35 2001 193 199
    • (2001) Caries Research , vol.35 , pp. 193-199
    • Haak, R.1    Wicht, M.J.2    Noack, M.J.3
  • 8
    • 0018933967 scopus 로고
    • Comparison between black and white backgrounds for ultrasonic images
    • R.C. Sanders Comparison between black and white backgrounds for ultrasonic images Journal of Clinical Ultrasound 8 1980 413 415
    • (1980) Journal of Clinical Ultrasound , vol.8 , pp. 413-415
    • Sanders, R.C.1
  • 9
    • 0024503277 scopus 로고
    • The diagnosis of pulmonary nodules: Comparison between standard and inverse digitized images and conventional chest radiographs
    • M. Sheline, I. Brikman, D. Epstein, J. Mezrich, H. Kundel, and R. Arenson The diagnosis of pulmonary nodules: comparison between standard and inverse digitized images and conventional chest radiographs AJR American Journal of Roentgenology 152 1989 261 263
    • (1989) AJR American Journal of Roentgenology , vol.152 , pp. 261-263
    • Sheline, M.1    Brikman, I.2    Epstein, D.3    Mezrich, J.4    Kundel, H.5    Arenson, R.6
  • 11
    • 0026906860 scopus 로고
    • Digital subtraction radiography for assessment of simulated root resorption cavities. Performance of conventional and reverse contrast modes
    • H. Hintze, A. Wenzel, F.M. Andreasen, and I. Sewerin Digital subtraction radiography for assessment of simulated root resorption cavities. Performance of conventional and reverse contrast modes Endodontics and Dental Traumatology 8 1992 149 154
    • (1992) Endodontics and Dental Traumatology , vol.8 , pp. 149-154
    • Hintze, H.1    Wenzel, A.2    Andreasen, F.M.3    Sewerin, I.4
  • 12
    • 0023784908 scopus 로고
    • Digital chest radiography: Effect on diagnostic accuracy of hard copy, conventional video, and reversed gray scale video display formats
    • H. MacMahon, C. Metz, K. Doi, T. Kim, M. Giger, and H. Chan Digital chest radiography: effect on diagnostic accuracy of hard copy, conventional video, and reversed gray scale video display formats Radiology 168 1988 669 673
    • (1988) Radiology , vol.168 , pp. 669-673
    • MacMahon, H.1    Metz, C.2    Doi, K.3    Kim, T.4    Giger, M.5    Chan, H.6
  • 13
    • 0023890533 scopus 로고
    • Subtle lung cancers: Impact of edge enhancement and gray scale reversal on detection with digitized chest radiographs
    • J. Oestmann, D. Kushner, P. Bourgouin, H. Llewellyn, B. Mockbee, and R. Greene Subtle lung cancers: impact of edge enhancement and gray scale reversal on detection with digitized chest radiographs Radiology 167 1988 657 658
    • (1988) Radiology , vol.167 , pp. 657-658
    • Oestmann, J.1    Kushner, D.2    Bourgouin, P.3    Llewellyn, H.4    Mockbee, B.5    Greene, R.6
  • 15
    • 0036562472 scopus 로고    scopus 로고
    • Influence of room lighting on grey-scale perception with a crt- and a tft monitor display
    • R. Haak, M.J. Wicht, M. Hellmich, G. Nowak, and M.J. Noack Influence of room lighting on grey-scale perception with a crt- and a tft monitor display Dentomaxillofacial Radiology 31 2002 193 197
    • (2002) Dentomaxillofacial Radiology , vol.31 , pp. 193-197
    • Haak, R.1    Wicht, M.J.2    Hellmich, M.3    Nowak, G.4    Noack, M.J.5
  • 20
    • 0029246074 scopus 로고
    • Introduction to perceptual linearization of video display systems for medical image presentation
    • B. Hemminger, R. Johnston, J. Rolland, and K. Muller Introduction to perceptual linearization of video display systems for medical image presentation Journal of Digital Imaging 8 1995 21 34
    • (1995) Journal of Digital Imaging , vol.8 , pp. 21-34
    • Hemminger, B.1    Johnston, R.2    Rolland, J.3    Muller, K.4
  • 22
    • 0345944803 scopus 로고
    • Specifications for medical diagnostic imaging test pattern for television monitors and hard-copy recording cameras. Recommended practice rp 133-1986
    • (SMPTE) Society of motion Pictures and Television Engineers Specifications for medical diagnostic imaging test pattern for television monitors and hard-copy recording cameras. Recommended practice rp 133-1986 SMPTE Journal 95 1986 693 695
    • (1986) SMPTE Journal , vol.95 , pp. 693-695
  • 24
    • 0024353587 scopus 로고
    • Impact of postprocessing on the detection of simulated pulmonary nodules with digital radiography
    • J. Oestmann, J. Rubens, P. Bourgouin, J. Rhea, H. Llewellyn, and R. Greene Impact of postprocessing on the detection of simulated pulmonary nodules with digital radiography Investigative Radiology 24 1989 467 471
    • (1989) Investigative Radiology , vol.24 , pp. 467-471
    • Oestmann, J.1    Rubens, J.2    Bourgouin, P.3    Rhea, J.4    Llewellyn, H.5    Greene, R.6
  • 25
    • 0020529379 scopus 로고
    • Digital radiography of the chest: Clinical experience with a prototype unit
    • R.G. Fraser, E. Breatnach, and G.T. Barnes Digital radiography of the chest: clinical experience with a prototype unit Radiology 148 1983 1 5
    • (1983) Radiology , vol.148 , pp. 1-5
    • Fraser, R.G.1    Breatnach, E.2    Barnes, G.T.3
  • 26
    • 0032250475 scopus 로고    scopus 로고
    • Detectability of artificial periapical lesions using direct digital and conventional radiography
    • J. Barbat, and H. Messer Detectability of artificial periapical lesions using direct digital and conventional radiography Journal of Endodontics 24 1998 837 842
    • (1998) Journal of Endodontics , vol.24 , pp. 837-842
    • Barbat, J.1    Messer, H.2
  • 27
    • 0026903337 scopus 로고
    • A comparison of conventional intra-oral radiography and computer imaging techniques for the detection of proximal surface dental caries
    • S.B. Dove, and W.D. McDavid A comparison of conventional intra-oral radiography and computer imaging techniques for the detection of proximal surface dental caries Dentomaxillofacial Radiology 21 1992 127 134
    • (1992) Dentomaxillofacial Radiology , vol.21 , pp. 127-134
    • Dove, S.B.1    McDavid, W.D.2
  • 28
    • 0642310333 scopus 로고    scopus 로고
    • Influence of displayed image size on radiographic detection of approximal caries
    • R. Haak, M.J. Wicht, G. Nowak, and M. Hellmich Influence of displayed image size on radiographic detection of approximal caries Dentomaxillofacial Radiology 32 2003 242 246
    • (2003) Dentomaxillofacial Radiology , vol.32 , pp. 242-246
    • Haak, R.1    Wicht, M.J.2    Nowak, G.3    Hellmich, M.4
  • 29
    • 19044383993 scopus 로고    scopus 로고
    • Automated hands-free image manipulation and viewing: A useful macro feature that assists radiologists in the viewing of chest and extremity digital radiographs
    • R.M. Koenker, and S.A. Grover Automated hands-free image manipulation and viewing: a useful macro feature that assists radiologists in the viewing of chest and extremity digital radiographs Journal of Digital Imaging 15 2002 166 170
    • (2002) Journal of Digital Imaging , vol.15 , pp. 166-170
    • Koenker, R.M.1    Grover, S.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.