메뉴 건너뛰기




Volumn 3, Issue , 2003, Pages 1833-1837

High-sensitivity dynamic coded aperture imaging

Author keywords

Coded aperture imaging; Dynamic scanning; Multiple pinholes; Scintigraphy

Indexed keywords

CAMERAS; GAMMA RAYS; IMAGE RECONSTRUCTION; OPTICAL COLLIMATORS; OPTICAL CORRELATION; SCANNING; SCINTILLATION; X RAYS;

EID: 11844280893     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/nssmic.2003.1352235     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 3
    • 0001341373 scopus 로고    scopus 로고
    • Near-field artifact reduction in Coded Aperture Imaging
    • R. Accorsi, and R. C. Lanza, "Near-field artifact reduction in Coded Aperture Imaging," Applied Optics, vol. 40, pp. 4697-4705, 2001.
    • (2001) Applied Optics , vol.40 , pp. 4697-4705
    • Accorsi, R.1    Lanza, R.C.2
  • 5
    • 0017935435 scopus 로고
    • Coded aperture imaging with uniformly redundant arrays
    • E. E. Fenimore, and T. M. Cannon, "Coded aperture imaging with uniformly redundant arrays," Applied Optics, vol. 17, pp. 337-347, 1978.
    • (1978) Applied Optics , vol.17 , pp. 337-347
    • Fenimore, E.E.1    Cannon, T.M.2
  • 6
    • 0018035137 scopus 로고
    • Coded aperture imaging: Predicted performance of uniformly redundant arrays
    • E. E. Fenimore, "Coded aperture imaging: predicted performance of uniformly redundant arrays," Applied Optics, vol. 17, pp. 3562-3570, 1978.
    • (1978) Applied Optics , vol.17 , pp. 3562-3570
    • Fenimore, E.E.1
  • 7
    • 0035846517 scopus 로고    scopus 로고
    • Optimal coded aperture patterns for improved SNR in nuclear medicine imaging
    • R. Accorsi, F. Gasparini, and R. C. Lanza, "Optimal coded aperture patterns for improved SNR in nuclear medicine imaging," Nuclear Instrument and Methods in Physics Research, vol. A474, no. 3, pp. 273-284, 2001.
    • (2001) Nuclear Instrument and Methods in Physics Research , vol.A474 , Issue.3 , pp. 273-284
    • Accorsi, R.1    Gasparini, F.2    Lanza, R.C.3
  • 8
    • 84975577929 scopus 로고
    • New family of binary arrays for coded aperture imaging
    • S. R. Gottesman, and E. E. Fenimore, "New family of binary arrays for coded aperture imaging," Applied Optics, vol. 28, pp. 4344-4352, 1989.
    • (1989) Applied Optics , vol.28 , pp. 4344-4352
    • Gottesman, S.R.1    Fenimore, E.E.2
  • 9
    • 0001376685 scopus 로고
    • Physical implementation of an antimask in URA based coded mask systems
    • U. B. Jayanthi, and J. Braga, "Physical implementation of an antimask in URA based coded mask systems," Nuclear Instruments and Methods in Physics Research, vol. A310, pp. 685-689, 1991.
    • (1991) Nuclear Instruments and Methods in Physics Research , vol.A310 , pp. 685-689
    • Jayanthi, U.B.1    Braga, J.2
  • 10
    • 0035725801 scopus 로고    scopus 로고
    • A coded aperture for high-resolution nuclear medicine planar imaging with a conventional Anger camera: Experimental results
    • R. Accorsi, F. Gasparini, and R. C. Lanza, "A coded aperture for high-resolution nuclear medicine planar imaging with a conventional Anger camera: experimental results," IEEE Transactions on Nuclear Science, vol. 48, pp. 2411-2417, 2001.
    • (2001) IEEE Transactions on Nuclear Science , vol.48 , pp. 2411-2417
    • Accorsi, R.1    Gasparini, F.2    Lanza, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.