메뉴 건너뛰기




Volumn 3, Issue , 2003, Pages 1904-1908

First in-beam PET imaging with LSO/APD-array detectors

Author keywords

APD; Ion therapy; LSO; PET; Proton therapy

Indexed keywords

ARRAYS; AVALANCHE DIODES; CARBON; DOPING (ADDITIVES); IRRADIATION; LUTETIUM COMPOUNDS; POSITRON EMISSION TOMOGRAPHY; TESTING; TUMORS;

EID: 11844276611     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/nssmic.2003.1352251     Document Type: Conference Paper
Times cited : (3)

References (13)
  • 1
    • 0030485026 scopus 로고    scopus 로고
    • Medical accelerators in radiotherapy: Past, present and future
    • W.H. Scharf, O.A. Chomicki, "Medical accelerators in radiotherapy: past, present and future." Physica Medica XII, vol.4, pp. 199-226, 1996.
    • (1996) Physica Medica XII , vol.4 , pp. 199-226
    • Scharf, W.H.1    Chomicki, O.A.2
  • 3
    • 0036669632 scopus 로고    scopus 로고
    • Acute radiation-induced toxicity of heavy ion radiotherapy delivered with intensity modulated pencil beam scanning in patients with base of skull tumors
    • D. Schulz-Ertner, T. Haberer, M. Scholz, C. Thilmann, F. Wenz, O.Jäkel, G. Kraft, M. Wannenmacher, J. Debus, "Acute radiation-induced toxicity of heavy ion radiotherapy delivered with intensity modulated pencil beam scanning in patients with base of skull tumors." Radiotherapy and Oncology, vol.64, pp. 189-195, 2002.
    • (2002) Radiotherapy and Oncology , vol.64 , pp. 189-195
    • Schulz-Ertner, D.1    Haberer, T.2    Scholz, M.3    Thilmann, C.4    Wenz, F.5    Jäkel, O.6    Kraft, G.7    Wannenmacher, M.8    Debus, J.9
  • 6
    • 11044237483 scopus 로고    scopus 로고
    • An interactive approach for local dose quantification from in-beam PET data
    • GSI 2002-1
    • K. Parodi, W. Enghardt, "An interactive approach for local dose quantification from in-beam PET data", GSI Ann. Report 2001. GSI 2002-1, pp. 171, 2002.
    • (2002) GSI Ann. Report 2001 , pp. 171
    • Parodi, K.1    Enghardt, W.2
  • 7
    • 8344268367 scopus 로고    scopus 로고
    • A technical feasibility study for a PET therapy monitor combined with a rotating ion beam delivery
    • Wiss.-Tech. Ber. FZR-372
    • W. Enghardt, P. Crespo, W. Bourgeois, A. Winter, "A technical feasibility study for a PET therapy monitor combined with a rotating ion beam delivery," FZR Ann. Report 2002, Wiss.-Tech. Ber. FZR-372, pp. 83-84, 2003.
    • (2003) FZR Ann. Report 2002 , pp. 83-84
    • Enghardt, W.1    Crespo, P.2    Bourgeois, W.3    Winter, A.4
  • 9
    • 4444237558 scopus 로고    scopus 로고
    • The time dependence of the γ-ray intensity seen by an in-beam PET monitor
    • Wiss.-Tech. Ber. FZR-372
    • K. Parodi, P. Crespo, W. Enghardt, T. Haberer, J. Pawelke, D. Schardt, "The time dependence of the γ-ray intensity seen by an in-beam PET monitor," FZR Ann. Report 2002, Wiss.-Tech. Ber. FZR-372, pp. 77, 2003.
    • (2003) FZR Ann. Report 2002 , pp. 77
    • Parodi, K.1    Crespo, P.2    Enghardt, W.3    Haberer, T.4    Pawelke, J.5    Schardt, D.6
  • 10
    • 8344229741 scopus 로고    scopus 로고
    • A CAMAC data acquisition system for multi parameter measurements
    • Wiss.-Tech. Ber., FZR-372
    • P. Crespo, J. Pawelke, W. Enghardt, "A CAMAC data acquisition system for multi parameter measurements," FZR Ann. Report 2002, Wiss.-Tech. Ber., FZR-372, pp. 82, 2003.
    • (2003) FZR Ann. Report 2002 , pp. 82
    • Crespo, P.1    Pawelke, J.2    Enghardt, W.3
  • 11
    • 0037507430 scopus 로고    scopus 로고
    • Characterisation of arrays of avalanche photodiodes for small animal positron emission tomography
    • J.B. Mosset, S. Saladino, J.F. Loude, C. Morel, "Characterisation of arrays of avalanche photodiodes for small animal positron emission tomography," Nucl. Instr. and Meth. A, vol. 504, pp. 325-330, 2003.
    • (2003) Nucl. Instr. and Meth. A , vol.504 , pp. 325-330
    • Mosset, J.B.1    Saladino, S.2    Loude, J.F.3    Morel, C.4
  • 12
    • 8344242749 scopus 로고    scopus 로고
    • A new fully 3D maximum likelihood PET reconstruction applicable to different detector arrangements
    • GSI 2002-1
    • P. Crespo, W. Enghardt, K. Lauckner, "A new fully 3D maximum likelihood PET reconstruction applicable to different detector arrangements," GSI Ann. Report 2001, GSI 2002-1, pp. 173-174, 2002.
    • (2002) GSI Ann. Report 2001 , pp. 173-174
    • Crespo, P.1    Enghardt, W.2    Lauckner, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.