메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 2799-2803

Towards model-based randoms correction for 3-D dual head coincidence imaging

Author keywords

[No Author keywords available]

Indexed keywords

CAMERAS; DEMODULATION; DETECTORS; MATHEMATICAL MODELS; MONTE CARLO METHODS; POSITRON EMISSION TOMOGRAPHY; SENSITIVITY ANALYSIS;

EID: 11844264847     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (6)
  • 1
    • 0034245289 scopus 로고    scopus 로고
    • Effect of shielding the radioactivity outside the field of view on image quality in a dual head coincidence camera
    • V. Sossi, B. Pointon, P. Cohen, R.R. Johnson, and T.J. Ruth, "Effect of shielding the radioactivity outside the field of view on image quality in a dual head coincidence camera," IEEE Trans. Nucl. Sci. no. 47, pp. 1561-1566, 2000.
    • (2000) IEEE Trans. Nucl. Sci. , Issue.47 , pp. 1561-1566
    • Sossi, V.1    Pointon, B.2    Cohen, P.3    Johnson, R.R.4    Ruth, T.J.5
  • 2
    • 11844288849 scopus 로고    scopus 로고
    • CMS-3077-N medicare program; withdrawal of medicare coverage of certain positron emission tomography (PET) scanners
    • Nov 23 / Notices
    • T. Scully, "CMS-3077-N Medicare Program; Withdrawal of Medicare Coverage of Certain Positron Emission Tomography (PET) Scanners," Federal Register Vol 66, No. 226 Nov 23, 2001/ Notices, 57841-57842.
    • (2001) Federal Register , vol.66 , Issue.226 , pp. 57841-57842
    • Scully, T.1
  • 4
    • 11844278376 scopus 로고    scopus 로고
    • Towards scatter correction for 3-D dual head coincidence imaging
    • B. Pointon B and V. Sossi, "Towards Scatter Correction for 3-D Dual Head Coincidence Imaging," J. Nucl. Med. 44(5): 275P. 2003.
    • (2003) J. Nucl. Med. , vol.44 , Issue.5
    • Pointon, B.1    Sossi, V.2
  • 5
    • 0001320737 scopus 로고    scopus 로고
    • A single scatter simulation technique for scatter correction in 3D PET
    • P. Grangeat and J.-L Amans Eds., Kluwer Academic Publishers, Dordrecht (NL)
    • C.C. Watson, D. Newport and M. E. Casey. "A Single Scatter Simulation Technique for Scatter Correction in 3D PET," in Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, P. Grangeat and J.-L Amans Eds., Kluwer Academic Publishers, Dordrecht (NL), 1996, pp. 255-268.
    • (1996) Three-dimensional Image Reconstruction in Radiology and Nuclear Medicine , pp. 255-268
    • Watson, C.C.1    Newport, D.2    Casey, M.E.3
  • 6
    • 0003063484 scopus 로고
    • A public-domain simulation system for emission tomography: Photon tracking through heterogeneous attenuation using importance sampling
    • R.L. Harrison, D.R. Haynor, S.B. Gillispie, S.D. Vannoy, M.S. Kaplan, T.K. Lewellen, "A public-domain simulation system for emission tomography: photon tracking through heterogeneous attenuation using importance sampling," J. Nucl. Med., no. 34(5): 60P, 1993.
    • (1993) J. Nucl. Med. , vol.34 , Issue.5
    • Harrison, R.L.1    Haynor, D.R.2    Gillispie, S.B.3    Vannoy, S.D.4    Kaplan, M.S.5    Lewellen, T.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.