메뉴 건너뛰기




Volumn 3, Issue , 2003, Pages 1489-1493

Verification of monte carlo calculations in fast neutron therapy using silicon microdosimetry

Author keywords

Fast neutron therapy; Microdosimetry; Monte carlo

Indexed keywords

DEPOSITION; ELECTRIC INSULATORS; MONTE CARLO METHODS; RADIATION; SILICON; STRATEGIC PLANNING; TISSUE;

EID: 11844258798     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/nssmic.2003.1352159     Document Type: Conference Paper
Times cited : (1)

References (17)
  • 7
  • 11
    • 0032976612 scopus 로고    scopus 로고
    • Performance of silicon microdosimetry detectors in boron neutron capture therapy
    • P. Bradley, A. B. Rosenfeld, B. J. Allen, J. Corderre, and J. Capela, "Performance of silicon microdosimetry detectors in boron neutron capture therapy," Radiation Research, vol. 151, pp. 235-243, 1999.
    • (1999) Radiation Research , vol.151 , pp. 235-243
    • Bradley, P.1    Rosenfeld, A.B.2    Allen, B.J.3    Corderre, J.4    Capela, J.5
  • 14
    • 0032962312 scopus 로고    scopus 로고
    • Monte carlo calculations to characterize the source for neutron therapy facilities
    • T. D. Bohm, P. M. D. Jr., R. L. Maughan, D. T. L. Jones, and A. Lennox, "Monte carlo calculations to characterize the source for neutron therapy facilities." Medical Physics, vol. 26, pp. 783-792, 1999.
    • (1999) Medical Physics , vol.26 , pp. 783-792
    • Bohm, T.D.1    D. Jr., P.M.2    Maughan, R.L.3    Jones, D.T.L.4    Lennox, A.5
  • 15
    • 84860059644 scopus 로고    scopus 로고
    • GEANT4, http://wwwinfo.cern.ch/asd/geant4/geant4.html.
    • GEANT4
  • 16
    • 0032243685 scopus 로고    scopus 로고
    • Charge collection and radiation hardness of a SOI microdosimeter for space and medical applications
    • P. Bradley, A. Rosenfeld, K. Lee, D. Jamieson, and S. Satoh, "Charge collection and radiation hardness of a SOI microdosimeter for space and medical applications." IEEE Transactions on Nuclear Science, vol. 45, no. 6, pp. 2700-2710, 1998.
    • (1998) IEEE Transactions on Nuclear Science , vol.45 , Issue.6 , pp. 2700-2710
    • Bradley, P.1    Rosenfeld, A.2    Lee, K.3    Jamieson, D.4    Satoh, S.5
  • 17
    • 1242287884 scopus 로고    scopus 로고
    • LET dependence of the charge collection efficiency of silicon microdosimeters
    • in print
    • I. Cornelius, A. Rosenfeld, R. Siegele, and D. Cohen, "LET dependence of the charge collection efficiency of silicon microdosimeters. " IEEE Transactions on Nuclear Science, vol. 50, no. 6, 2003, in print.
    • (2003) IEEE Transactions on Nuclear Science , vol.50 , Issue.6
    • Cornelius, I.1    Rosenfeld, A.2    Siegele, R.3    Cohen, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.