메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 2707-2711

A robust and versatile method for the quantification of myocardial infarct size

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; ATTENUATION; BIOLOGICAL ORGANS; COMPUTER SIMULATION; COMPUTER SOFTWARE; DATABASE SYSTEMS; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; MATRIX ALGEBRA; MEDICAL IMAGING; OPTICAL COLLIMATORS; PHOTOEMISSION; RELIABILITY; TISSUE;

EID: 11844251200     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (13)
  • 1
    • 0027186057 scopus 로고
    • Nuclear cardiology (1)
    • B.L Zaret and F.J. Wackers. Nuclear cardiology (1). N. Engl J. Med. 1993;329(11):775-783.
    • (1993) N. Engl J. Med. , vol.329 , Issue.11 , pp. 775-783
    • Zaret, B.L.1    Wackers, F.J.2
  • 2
    • 0034033807 scopus 로고    scopus 로고
    • A new algorithm for the quantitation of muocardial perfusion SPECT. I: Technical principles and reproducibility
    • Germane G, Kavanagh PB, Waechter P, Areeda J, Van Kriekinge S, Sharir T, et al. A new algorithm for the quantitation of muocardial perfusion SPECT. I: Technical principles and reproducibility. J. Nucl. Med. 2000;41(4):712-9.
    • (2000) J. Nucl. Med. , vol.41 , Issue.4 , pp. 712-719
    • Germane, G.1    Kavanagh, P.B.2    Waechter, P.3    Areeda, J.4    Van Kriekinge, S.5    Sharir, T.6
  • 3
    • 0032908274 scopus 로고    scopus 로고
    • Left ventricle function and perfusion from gated SPECT perfusion images: An integrated method
    • Faber TL, Cooke D, Folks RD. Vansant JP, Nichols KJ, DePuey G, et al. Left ventricle function and perfusion from gated SPECT perfusion images: An integrated method. J. Nucl. Med. 1999;40(4):650-9.
    • (1999) J. Nucl. Med. , vol.40 , Issue.4 , pp. 650-659
    • Faber, T.L.1    Cooke, D.2    Folks, R.D.3    Vansant, J.P.4    Nichols, K.J.5    DePuey, G.6
  • 4
    • 0028269283 scopus 로고
    • Multicenter trial validation for quantitative analysis of same-day reststress Technetium-99m-sestamibi myocardial tomographs
    • Van Train KF, Garcia EV, Maddahi J, Areeda J, Cooke CD, Kiat H, et al. Multicenter trial validation for quantitative analysis of same-day reststress Technetium-99m-Sestamibi myocardial tomographs. J. Nucl. Med. 1994:35(4):609-18.
    • (1994) J. Nucl. Med. , vol.35 , Issue.4 , pp. 609-618
    • Van Train, K.F.1    Garcia, E.V.2    Maddahi, J.3    Areeda, J.4    Cooke, C.D.5    Kiat, H.6
  • 5
    • 0003117834 scopus 로고    scopus 로고
    • Development and clinical validation of normal Tc-99m sestimibi database: Comparison of 3D-MSPECT to CEqual
    • Ficaro EP, Kritzman JN, Corbett JR. Development and clinical validation of normal Tc-99m sestimibi database: Comparison of 3D-MSPECT to CEqual. J. Nucl. Med. 1999;40(5 Supplement): 125P.
    • (1999) J. Nucl. Med. , vol.40 , Issue.5 SUPPL. , pp. 125
    • Ficaro, E.P.1    Kritzman, J.N.2    Corbett, J.R.3
  • 6
    • 0029009640 scopus 로고
    • Automated alignment and sizing of myocardial stress and rest scans to three-dimensional normal templates using an image registration algorithm
    • Slomka PJ, Hurwitz GA, Stephenson J, Cradduck T. Automated alignment and sizing of myocardial stress and rest scans to three-dimensional normal templates using an image registration algorithm. J. Nucl. Med. 1995;36(6):1115-22.
    • (1995) J. Nucl. Med. , vol.36 , Issue.6 , pp. 1115-1122
    • Slomka, P.J.1    Hurwitz, G.A.2    Stephenson, J.3    Cradduck, T.4
  • 7
    • 0028010907 scopus 로고
    • Modelling the integration of myocardial regional perfusion and function
    • Goris ML, Thompson C, Malone LJ, Franken PR. Modelling the integration of myocardial regional perfusion and function. Nuc. Med. Com. 1994;15(1):9-20.
    • (1994) Nuc. Med. Com. , vol.15 , Issue.1 , pp. 9-20
    • Goris, M.L.1    Thompson, C.2    Malone, L.J.3    Franken, P.R.4
  • 8
    • 0033900319 scopus 로고    scopus 로고
    • Validation of the Yale circumferential quantification method using Tl-201 and Tc-99m: A phantom study
    • Kirac S, Wackers FJT, Yi-Hwa Liu. Validation of the Yale circumferential quantification method using Tl-201 and Tc-99m: A phantom study. J. Nucl. Med. 2000;41(8): 1436-41.
    • (2000) J. Nucl. Med. , vol.41 , Issue.8 , pp. 1436-1441
    • Kirac, S.1    Wackers, F.J.T.2    Liu, Y.-H.3
  • 11
    • 0030761578 scopus 로고    scopus 로고
    • Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom for gated pool SPECT
    • P.H. Pretorius, W. Xia, M.A. King, B.M.W. Tsui, T.S. Pan and B.J. Villegas. Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom for gated pool SPECT. J. Nuc. Med. 1997;38(10):1528-1534.
    • (1997) J. Nuc. Med. , vol.38 , Issue.10 , pp. 1528-1534
    • Pretorius, P.H.1    Xia, W.2    King, M.A.3    Tsui, B.M.W.4    Pan, T.S.5    Villegas, B.J.6
  • 13
    • 0025940237 scopus 로고
    • The use of importance sampling techniques to improve the efficiency of photon tracking in emission tomography simulations
    • D. R. Haynor, R. L. Harrison and T. K. Lewellen, "The use of importance sampling techniques to improve the efficiency of photon tracking in emission tomography simulations," Med. Phys., vol. 18, no. 5. pp. 990-1001, 1991.
    • (1991) Med. Phys. , vol.18 , Issue.5 , pp. 990-1001
    • Haynor, D.R.1    Harrison, R.L.2    Lewellen, T.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.