메뉴 건너뛰기




Volumn 15, Issue 1, 2004, Pages 63-84

The use of evoked potentials in intraoperative neurophysiologic monitoring

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN PROTECTION; DIAGNOSTIC APPROACH ROUTE; ELECTROMYOGRAPHY; EPILEPTOGENESIS; EVOKED AUDITORY RESPONSE; EVOKED RESPONSE; EVOKED SOMATOSENSORY RESPONSE; EVOKED VISUAL RESPONSE; NERVOUS TISSUE; NEUROPHYSIOLOGY; NEURORADIOLOGY; NEUROSURGERY; OPERATING ROOM; PATIENT MONITORING; PRIORITY JOURNAL; REVIEW;

EID: 1142267459     PISSN: 10479651     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1047-9651(03)00098-6     Document Type: Review
Times cited : (25)

References (67)
  • 1
    • 0345082647 scopus 로고
    • Electroencephalographic monitoring during reconstructive surgery of the neck vessels
    • Perez-Borja C., Meyer J.S. Electroencephalographic monitoring during reconstructive surgery of the neck vessels. Electroencephalogr Clin Neurophysiol. 18:1965;162-169.
    • (1965) Electroencephalogr Clin Neurophysiol , vol.18 , pp. 162-169
    • Perez-Borja, C.1    Meyer, J.S.2
  • 2
    • 0016159268 scopus 로고
    • Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy
    • Sundt T.M., Sharbrough F.W., Anderson R.E., Michenfelder J.D. Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy. J Neurosurg. 41:1974;310-320.
    • (1974) J Neurosurg , vol.41 , pp. 310-320
    • Sundt, T.M.1    Sharbrough, F.W.2    Anderson, R.E.3    Michenfelder, J.D.4
  • 3
    • 0015793460 scopus 로고
    • Correlation of continuous electroencephalograms with cerebral blood flow measurements during carotid endarterectomy
    • Sharbrough F., Messick J., Sundt T.M. Correlation of continuous electroencephalograms with cerebral blood flow measurements during carotid endarterectomy. Stroke. 4:1973;674-683.
    • (1973) Stroke , vol.4 , pp. 674-683
    • Sharbrough, F.1    Messick, J.2    Sundt, T.M.3
  • 4
    • 0019820832 scopus 로고
    • Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy with results of surgery and hemodynamics of cerebral ischemia
    • Sundt T.M., Sharbrough F., Piepgras D.G., Kearns T.P., Messick J.M., O'Fallon W.M. Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy with results of surgery and hemodynamics of cerebral ischemia. Mayo Clin Proc. 56:1981;533-543.
    • (1981) Mayo Clin Proc , vol.56 , pp. 533-543
    • Sundt, T.M.1    Sharbrough, F.2    Piepgras, D.G.3    Kearns, T.P.4    Messick, J.M.5    O'Fallon, W.M.6
  • 5
    • 0016302747 scopus 로고
    • Relationship between the cortical evoked potential and local cortical blood flow following acute middle cerebral artery occlusion in the baboon
    • Branston N.M., Symon L., Crockard H.A., Pasztor E. Relationship between the cortical evoked potential and local cortical blood flow following acute middle cerebral artery occlusion in the baboon. Exp Neurol. 45:1974;195-208.
    • (1974) Exp Neurol , vol.45 , pp. 195-208
    • Branston, N.M.1    Symon, L.2    Crockard, H.A.3    Pasztor, E.4
  • 6
    • 0017380161 scopus 로고
    • Extracellular potassium activity, evoked potential and tissue blood flow: Relationships during progressive ischaemia in baboon cerebral cortex
    • Branston N.M., Strong A.J., Symon L. Extracellular potassium activity, evoked potential and tissue blood flow: relationships during progressive ischaemia in baboon cerebral cortex. J Neurol Sci. 32:1977;305-321.
    • (1977) J Neurol Sci , vol.32 , pp. 305-321
    • Branston, N.M.1    Strong, A.J.2    Symon, L.3
  • 7
    • 0021368492 scopus 로고
    • Comparison of the effects of ischaemia on early components of the somatosensory evoked potential in brainstem, thalamus, and cerebral cortex
    • Branston N.M., Ladds A., Symon L., Wang A.D. Comparison of the effects of ischaemia on early components of the somatosensory evoked potential in brainstem, thalamus, and cerebral cortex. J Cereb Blood Flow Metabol. 4:1984;68-81.
    • (1984) J Cereb Blood Flow Metabol , vol.4 , pp. 68-81
    • Branston, N.M.1    Ladds, A.2    Symon, L.3    Wang, A.D.4
  • 8
    • 84981893550 scopus 로고
    • The relationship between CBF, evoked potentials and the clinical features in cerebral ischaemia. Proc 23rd Scand Neurol Congress
    • Symon L. The relationship between CBF, evoked potentials and the clinical features in cerebral ischaemia. Proc 23rd Scand Neurol Congress. Acta Neurol Scand. 62:(Suppl):1980;175-190.
    • (1980) Acta Neurol Scand , vol.62 , Issue.SUPPL , pp. 175-190
    • Symon, L.1
  • 9
    • 0019209277 scopus 로고
    • Central conduction time in primate brain ischemia - A study in baboons
    • Hargadine J.R., Branston N.M., Symon L. Central conduction time in primate brain ischemia - a study in baboons. Stroke. 11:1980;637-642.
    • (1980) Stroke , vol.11 , pp. 637-642
    • Hargadine, J.R.1    Branston, N.M.2    Symon, L.3
  • 10
    • 0021329708 scopus 로고
    • Alteration of somatosensory evoked potentials in response to global ischemia
    • Lesnick J.E., Michele J.J., Simeone F.A., DeFeo S., Welsh F.A. Alteration of somatosensory evoked potentials in response to global ischemia. J Neurosurg. 60:1984;490-494.
    • (1984) J Neurosurg , vol.60 , pp. 490-494
    • Lesnick, J.E.1    Michele, J.J.2    Simeone, F.A.3    Defeo, S.4    Welsh, F.A.5
  • 11
    • 0019989380 scopus 로고
    • Energy-requiring cell functions in the ischemic brain: Their critical supply and possible inhibition in protective therapy
    • Astrup J. Energy-requiring cell functions in the ischemic brain: their critical supply and possible inhibition in protective therapy. J Neurosurg. 56:1982;482-497.
    • (1982) J Neurosurg , vol.56 , pp. 482-497
    • Astrup, J.1
  • 12
    • 0016770896 scopus 로고
    • Local cerebral blood flow and vascular reactivity in a chronic stable stroke in baboons
    • Symon L., Crockard H.A., Dorsch N.W.C., Branston N.M., Juhasz J. Local cerebral blood flow and vascular reactivity in a chronic stable stroke in baboons. Stroke. 6:1975;482-492.
    • (1975) Stroke , vol.6 , pp. 482-492
    • Symon, L.1    Crockard, H.A.2    Dorsch, N.W.C.3    Branston, N.M.4    Juhasz, J.5
  • 13
    • 0017801454 scopus 로고
    • Cerebral blood flow determined by hydrogen clearance during middle cerebral artery occlusion in unanesthetized monkeys
    • Morawetz R.B., DeGiorlami U., Ojemann R.G., Marcoux F.W., Crowell R.M. Cerebral blood flow determined by hydrogen clearance during middle cerebral artery occlusion in unanesthetized monkeys. Stroke. 9:1978;143-149.
    • (1978) Stroke , vol.9 , pp. 143-149
    • Morawetz, R.B.1    Degiorlami, U.2    Ojemann, R.G.3    Marcoux, F.W.4    Crowell, R.M.5
  • 14
    • 0019582748 scopus 로고
    • Thresholds of focal ischemia in awake monkeys
    • Jones T.H., Morawetz R.B., Crowell R.M., et al. Thresholds of focal ischemia in awake monkeys. J Neurosurg. 54:1981;773-782.
    • (1981) J Neurosurg , vol.54 , pp. 773-782
    • Jones, T.H.1    Morawetz, R.B.2    Crowell, R.M.3
  • 15
    • 0016846243 scopus 로고
    • Successful carotid endarterectomy for cerebrovascular insufficiency: Nineteen-year follow-up
    • DeBakey M.E. Successful carotid endarterectomy for cerebrovascular insufficiency: nineteen-year follow-up. JAMA. 233:1975;1083-1985.
    • (1975) JAMA , vol.233 , pp. 1083-1985
    • Debakey, M.E.1
  • 16
    • 0025734372 scopus 로고
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high grade stenosis
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high grade stenosis. N Engl J Med. 325:1991;445-453.
    • (1991) N Engl J Med , vol.325 , pp. 445-453
  • 17
    • 0028938324 scopus 로고
    • Endarterectomy for asymptomatic carotid artery stenosis
    • Executive Committee for the Asymptomatic Carotid Atherosclerosis Study. Endarterectomy for asymptomatic carotid artery stenosis. JAMA. 273:1995;1421-1428.
    • (1995) JAMA , vol.273 , pp. 1421-1428
  • 18
    • 0018850652 scopus 로고
    • Carotid endarterectomy and alternative approach
    • Whittemore A.D. Carotid endarterectomy and alternative approach. Arch Surg. 115:1980;940-942.
    • (1980) Arch Surg , vol.115 , pp. 940-942
    • Whittemore, A.D.1
  • 19
    • 0028968047 scopus 로고
    • Technical issues in carotid artery surgery 1995
    • Loftus C.M., Quest D.O. Technical issues in carotid artery surgery 1995. Neurosurgery. 36:1995;629-647.
    • (1995) Neurosurgery , vol.36 , pp. 629-647
    • Loftus, C.M.1    Quest, D.O.2
  • 20
    • 0028855150 scopus 로고
    • Efficacy of intraoperative neurophysiological monitoring
    • Fisher R.S., Raudzens P., Nunemacher M. Efficacy of intraoperative neurophysiological monitoring. J Clin Neurophysiol. 12:1995;97-109.
    • (1995) J Clin Neurophysiol , vol.12 , pp. 97-109
    • Fisher, R.S.1    Raudzens, P.2    Nunemacher, M.3
  • 21
    • 0022461879 scopus 로고
    • Multicenter retrospective review of results and complications of carotid endarterectomy in 1981
    • Fode N.C., Sundt T.M., Robertson J.T., Peerless S.J., Shields C.B. Multicenter retrospective review of results and complications of carotid endarterectomy in 1981. Stroke. 17:1986;370-376.
    • (1986) Stroke , vol.17 , pp. 370-376
    • Fode, N.C.1    Sundt, T.M.2    Robertson, J.T.3    Peerless, S.J.4    Shields, C.B.5
  • 22
    • 0026453498 scopus 로고
    • Risks and benefits of shunting in carotid endarterectomy
    • Halsey J.H. Risks and benefits of shunting in carotid endarterectomy. Stroke. 23:1992;1583-1587.
    • (1992) Stroke , vol.23 , pp. 1583-1587
    • Halsey, J.H.1
  • 23
    • 0022550807 scopus 로고
    • Distal cervical carotid dissection after carotid endarterectomy: A complication of indwelling shunt?
    • Loftus C.M., Dyste G.N., Reinarz S.J., Hingtgen W.L. Distal cervical carotid dissection after carotid endarterectomy: a complication of indwelling shunt? Neurosurgery. 19:1986;441-445.
    • (1986) Neurosurgery , vol.19 , pp. 441-445
    • Loftus, C.M.1    Dyste, G.N.2    Reinarz, S.J.3    Hingtgen, W.L.4
  • 24
    • 0021474753 scopus 로고
    • A simple solution for determining shunt flow during carotid endarterectomy
    • Lindsey R.L. A simple solution for determining shunt flow during carotid endarterectomy. Anesthesiology. 61:1984;215-216.
    • (1984) Anesthesiology , vol.61 , pp. 215-216
    • Lindsey, R.L.1
  • 25
    • 0003043486 scopus 로고
    • Continuous assessment of cerebral function with EEG and somatosensory evoked potential techniques during extracranial vascular reconstruction
    • C.M. Loftus, & V.C. Traynelis. New York: McGraw-Hill
    • Markand O.N. Continuous assessment of cerebral function with EEG and somatosensory evoked potential techniques during extracranial vascular reconstruction. Loftus C.M., Traynelis V.C. Intraoperative monitoring techniques in neurosurgery. 1994;19-32 McGraw-Hill, New York.
    • (1994) Intraoperative Monitoring Techniques in Neurosurgery , pp. 19-32
    • Markand, O.N.1
  • 27
    • 0021325403 scopus 로고
    • Monitoring of somatosensory evoked responses during carotid endarterectomy
    • Markand O.N., Dilley R.S., Moorthy S., Warren C. Monitoring of somatosensory evoked responses during carotid endarterectomy. Arch Neurol. 41:1984;375-378.
    • (1984) Arch Neurol , vol.41 , pp. 375-378
    • Markand, O.N.1    Dilley, R.S.2    Moorthy, S.3    Warren, C.4
  • 28
    • 0023203313 scopus 로고
    • Monitoring of subcortical and cortical somatosensory evoked potentials during carotid endarterectomy: Comparison with stump pressure levels
    • Gigli G.L., Caramia M., Marciani M.G., Zarola F., Lavaroni F., Rossini P.M. Monitoring of subcortical and cortical somatosensory evoked potentials during carotid endarterectomy: comparison with stump pressure levels. Electroencephalogr Clin Neurophysiol. 68:1987;424-432.
    • (1987) Electroencephalogr Clin Neurophysiol , vol.68 , pp. 424-432
    • Gigli, G.L.1    Caramia, M.2    Marciani, M.G.3    Zarola, F.4    Lavaroni, F.5    Rossini, P.M.6
  • 29
    • 0026609577 scopus 로고
    • Evoked potential monitoring in carotid surgery: A review of 994 cases
    • Haupt W.F., Horsch S. Evoked potential monitoring in carotid surgery: a review of 994 cases. Neurology. 42:1992;835-838.
    • (1992) Neurology , vol.42 , pp. 835-838
    • Haupt, W.F.1    Horsch, S.2
  • 30
    • 0025729805 scopus 로고
    • Somatosensory-evoked potentials during carotid artery surgery: Experience in 400 operations
    • Schweiger H., Kamp H.D., Dinkel M. Somatosensory-evoked potentials during carotid artery surgery: experience in 400 operations. Surgery. 109:1991;602-609.
    • (1991) Surgery , vol.109 , pp. 602-609
    • Schweiger, H.1    Kamp, H.D.2    Dinkel, M.3
  • 31
    • 0026576783 scopus 로고
    • Monitoring of somatosensory evoked potentials during carotid endarterectomy
    • Amantini A., Bartelli M., de Scisciolo G., et al. Monitoring of somatosensory evoked potentials during carotid endarterectomy. J Neurol. 239:1992;241-247.
    • (1992) J Neurol , vol.239 , pp. 241-247
    • Amantini, A.1    Bartelli, M.2    De Scisciolo, G.3
  • 32
    • 0026045022 scopus 로고
    • Monitoring of somatosensory evoked potentials during carotid endarterectomy: Relationship with different haemodynamic parameters and clinical outcome
    • Tiberio G., Floriani M., Giulini S.M., et al. Monitoring of somatosensory evoked potentials during carotid endarterectomy: relationship with different haemodynamic parameters and clinical outcome. Eur J Vasc Surg. 5:1991;647-653.
    • (1991) Eur J Vasc Surg , vol.5 , pp. 647-653
    • Tiberio, G.1    Floriani, M.2    Giulini, S.M.3
  • 33
    • 0026555704 scopus 로고
    • Somatosensory evoked potential sensitivity relative to electroencephalography for cerebral ischemia during carotid endarterectomy
    • Kearse L.A., Brown E.N., McPeck K. Somatosensory evoked potential sensitivity relative to electroencephalography for cerebral ischemia during carotid endarterectomy. Stroke. 23:1992;498-505.
    • (1992) Stroke , vol.23 , pp. 498-505
    • Kearse, L.A.1    Brown, E.N.2    McPeck, K.3
  • 35
    • 0025986370 scopus 로고
    • Monitoring electrophysiologic function during carotid endarterectomy: A comparison of somatosensory evoked potentials and conventional electroencephalogram
    • Lam A.M., Manninen P.H., Ferguson G.G., Nantau W. Monitoring electrophysiologic function during carotid endarterectomy: a comparison of somatosensory evoked potentials and conventional electroencephalogram. Anesthesiology. 75:1991;15-21.
    • (1991) Anesthesiology , vol.75 , pp. 15-21
    • Lam, A.M.1    Manninen, P.H.2    Ferguson, G.G.3    Nantau, W.4
  • 36
    • 0344589352 scopus 로고    scopus 로고
    • Monitoring of median nerve somatosensory evoked potentials in carotid surgery
    • Wöber C., Zeitlhofer J., Asenbaum S., et al. Monitoring of median nerve somatosensory evoked potentials in carotid surgery. J Clin Neurophys. 15:1998;429-438.
    • (1998) J Clin Neurophys , vol.15 , pp. 429-438
    • Wöber, C.1    Zeitlhofer, J.2    Asenbaum, S.3
  • 37
    • 0034961070 scopus 로고    scopus 로고
    • Somatosensory evoked potential monitoring during carotid endarterectomy in patients with a stroke
    • Manninen P., Tan T., Sarjeant R.M. Somatosensory evoked potential monitoring during carotid endarterectomy in patients with a stroke. Anesth Analg. 93:2001;39-44.
    • (2001) Anesth Analg , vol.93 , pp. 39-44
    • Manninen, P.1    Tan, T.2    Sarjeant, R.M.3
  • 38
    • 0027155993 scopus 로고
    • Computer-derived density spectral array in detection of mild analog electroencephalographic ischemic pattern changes during carotid endarterectomy
    • Kearse L.A., Martin D., McPeck K., Lopez-Breshnahan M. Computer-derived density spectral array in detection of mild analog electroencephalographic ischemic pattern changes during carotid endarterectomy. J Neurosurg. 78:1993;884-890.
    • (1993) J Neurosurg , vol.78 , pp. 884-890
    • Kearse, L.A.1    Martin, D.2    McPeck, K.3    Lopez-Breshnahan, M.4
  • 39
    • 0021252503 scopus 로고
    • Neuropsychological performance one week after carotid endarterectomy reflects intra-operative ischemia
    • Brinkman S.D., Braun P., Ganji S., Morrell R.M., Jacobs L.A. Neuropsychological performance one week after carotid endarterectomy reflects intra-operative ischemia. Stroke. 15:1984;497-503.
    • (1984) Stroke , vol.15 , pp. 497-503
    • Brinkman, S.D.1    Braun, P.2    Ganji, S.3    Morrell, R.M.4    Jacobs, L.A.5
  • 40
    • 0023859214 scopus 로고
    • Monitoring of somatosensory evoked potentials in carotid surgery: Results, usefulness and limitations of the method
    • De Vleeschauwer P., Horsch S., Matamoros R. Monitoring of somatosensory evoked potentials in carotid surgery: results, usefulness and limitations of the method. Ann Vasc Surg. 2:1988;63-68.
    • (1988) Ann Vasc Surg , vol.2 , pp. 63-68
    • De Vleeschauwer, P.1    Horsch, S.2    Matamoros, R.3
  • 41
    • 0027527349 scopus 로고
    • Monitoring during supratentorial surgery
    • Emerson R.G., Turner C.A. Monitoring during supratentorial surgery. J Clin Neurophysiol. 10:1993;404-411.
    • (1993) J Clin Neurophysiol , vol.10 , pp. 404-411
    • Emerson, R.G.1    Turner, C.A.2
  • 42
    • 0026457727 scopus 로고
    • Somatosensory evoked potentials in cerebral aneurysm surgery
    • Buchtal A., Belopavlovic M. Somatosensory evoked potentials in cerebral aneurysm surgery. Eur J Anaesth. 9:1992;493-497.
    • (1992) Eur J Anaesth , vol.9 , pp. 493-497
    • Buchtal, A.1    Belopavlovic, M.2
  • 43
    • 0020638689 scopus 로고
    • Correlation of transient neurological deficit and somatosensory evoked potentials after intracranial aneurysm surgery
    • McPhearson R.W., Niedermeyer E.F., Otenasek R.J., Hanley D.F. Correlation of transient neurological deficit and somatosensory evoked potentials after intracranial aneurysm surgery. J Neurosurg. 59:1983;146-149.
    • (1983) J Neurosurg , vol.59 , pp. 146-149
    • McPhearson, R.W.1    Niedermeyer, E.F.2    Otenasek, R.J.3    Hanley, D.F.4
  • 44
    • 0021353978 scopus 로고
    • Perioperative use of somatosensory evoked responses in aneurysm surgery
    • Symon L., Wang A.D., Costa E., Silva I.E., Gentill F. Perioperative use of somatosensory evoked responses in aneurysm surgery. J Neurosurg. 60:1984;269-275.
    • (1984) J Neurosurg , vol.60 , pp. 269-275
    • Symon, L.1    Wang, A.D.2    Costa, E.3    Silva, I.E.4    Gentill, F.5
  • 45
    • 0023272511 scopus 로고
    • Evoked potential monitoring during aneurysm operation: Observations after fifty cases
    • Friedman W.A., Kaplan B.L., Day A.L., Sypert G.W., Curran M.T. Evoked potential monitoring during aneurysm operation: observations after fifty cases. Neurosurgery. 20:1987;678-687.
    • (1987) Neurosurgery , vol.20 , pp. 678-687
    • Friedman, W.A.1    Kaplan, B.L.2    Day, A.L.3    Sypert, G.W.4    Curran, M.T.5
  • 46
    • 0023754931 scopus 로고
    • Assessment of reversible cerebral ischaemia in man: Intraoperative monitoring of the somatosensory evoked response
    • Symon L., Momma F., Murota T. Assessment of reversible cerebral ischaemia in man: intraoperative monitoring of the somatosensory evoked response. Acta Neurochir. 42:(Suppl):1988;3-7.
    • (1988) Acta Neurochir , vol.42 , Issue.SUPPL , pp. 3-7
    • Symon, L.1    Momma, F.2    Murota, T.3
  • 47
    • 0023951088 scopus 로고
    • Evoked potential monitoring and temporary clipping in cerebral aneurysm surgery
    • Buchtal A., Belopavlovic M., Mooij J.J.A. Evoked potential monitoring and temporary clipping in cerebral aneurysm surgery. Acta Neurochir. 93:1988;28-36.
    • (1988) Acta Neurochir , vol.93 , pp. 28-36
    • Buchtal, A.1    Belopavlovic, M.2    Mooij, J.J.A.3
  • 48
    • 0023154837 scopus 로고
    • Effects of temporary occlusion on somatosensory evoked responses in aneurysm surgery
    • Momma F., Wand A.D., Symon L. Effects of temporary occlusion on somatosensory evoked responses in aneurysm surgery. Surg Neurol. 27:1987;343-352.
    • (1987) Surg Neurol , vol.27 , pp. 343-352
    • Momma, F.1    Wand, A.D.2    Symon, L.3
  • 49
    • 0025313495 scopus 로고
    • Surgical and electrophysiological observations during clipping of 134 aneurysms with evoked potential monitoring
    • Schramm J., Koht A., Schmidt G., Pechstein U., Taniguchi M., Fahlbusch R. Surgical and electrophysiological observations during clipping of 134 aneurysms with evoked potential monitoring. Neurosurgery. 26:1990;61-70.
    • (1990) Neurosurgery , vol.26 , pp. 61-70
    • Schramm, J.1    Koht, A.2    Schmidt, G.3    Pechstein, U.4    Taniguchi, M.5    Fahlbusch, R.6
  • 50
    • 0025953483 scopus 로고
    • Monitoring of somatosensory evoked potentials during surgery for middle cerebral artery aneurysms
    • Friedman W.A., Chadwick M.A., Verhoeven F.J., Mahla M., Day A.L. Monitoring of somatosensory evoked potentials during surgery for middle cerebral artery aneurysms. Neurosurgery. 29:1991;83-88.
    • (1991) Neurosurgery , vol.29 , pp. 83-88
    • Friedman, W.A.1    Chadwick, M.A.2    Verhoeven, F.J.3    Mahla, M.4    Day, A.L.5
  • 51
    • 0027080621 scopus 로고
    • Somatosensory evoked potential monitoring during intracranial surgery
    • Djuric S., Milenkovic Z., Klopcic-Spevak M., Spasic M. Somatosensory evoked potential monitoring during intracranial surgery. Acta Neurochir. 119:1992;85-90.
    • (1992) Acta Neurochir , vol.119 , pp. 85-90
    • Djuric, S.1    Milenkovic, Z.2    Klopcic-Spevak, M.3    Spasic, M.4
  • 52
    • 0032941752 scopus 로고    scopus 로고
    • The use of electrophysiological monitoring in the interoperative management of intracranial aneurysms
    • López J.R., Chang S.D., Steinberg G.K. The use of electrophysiological monitoring in the interoperative management of intracranial aneurysms. J Neurol Neurosurg Psychiatry. 66:1999;189-196.
    • (1999) J Neurol Neurosurg Psychiatry , vol.66 , pp. 189-196
    • López, J.R.1    Chang, S.D.2    Steinberg, G.K.3
  • 53
    • 77949811805 scopus 로고    scopus 로고
    • The usefulness of electrophysiological monitoring during resection of central nervous system vascular malformations
    • Chang S.D., López J.R., Steinberg G.K. The usefulness of electrophysiological monitoring during resection of central nervous system vascular malformations. J Stroke Cerebrovasc Dis. 8:1999;412-422.
    • (1999) J Stroke Cerebrovasc Dis , vol.8 , pp. 412-422
    • Chang, S.D.1    López, J.R.2    Steinberg, G.K.3
  • 54
    • 0010539327 scopus 로고
    • SSEP and BAEP monitoring of temporary clip application and induced hypotension during cerebrovascular surgery
    • C.M. Loftus, & V.C. Traynelis. New York: McGraw-Hill
    • Palatinsky E., DiScenna A., McDonald H., Whittingham T., Selman W. SSEP and BAEP monitoring of temporary clip application and induced hypotension during cerebrovascular surgery. Loftus C.M., Traynelis V.C. Intraoperative monitoring techniques in neurosurgery. 1994;61-71 McGraw-Hill, New York.
    • (1994) Intraoperative Monitoring Techniques in Neurosurgery , pp. 61-71
    • Palatinsky, E.1    Discenna, A.2    McDonald, H.3    Whittingham, T.4    Selman, W.5
  • 55
    • 0023782633 scopus 로고
    • Monitoring of brain function by means of evoked potentials in cerebral aneurysm surgery
    • Ducati A., Landi A., Cenzato M., et al. Monitoring of brain function by means of evoked potentials in cerebral aneurysm surgery. Acta Neurochir. 42:(Suppl):1988;8-13.
    • (1988) Acta Neurochir , vol.42 , Issue.SUPPL , pp. 8-13
    • Ducati, A.1    Landi, A.2    Cenzato, M.3
  • 56
    • 0027184174 scopus 로고
    • Permissible temporary occlusion time in aneurysm surgery as evaluated by evoked potential monitoring
    • Mizoi K., Yoshimoto T. Permissible temporary occlusion time in aneurysm surgery as evaluated by evoked potential monitoring. Neurosurgery. 33:1993;434-440.
    • (1993) Neurosurgery , vol.33 , pp. 434-440
    • Mizoi, K.1    Yoshimoto, T.2
  • 57
    • 0019951570 scopus 로고
    • Monitoring of cortical somatosensory evoked potentials to determine the safety of sacrificing the anterior cerebral artery
    • Grundy B.L., Nelson P.B., Lina A., Heros R.C. Monitoring of cortical somatosensory evoked potentials to determine the safety of sacrificing the anterior cerebral artery. Neurosurgery. 11:1982;64-67.
    • (1982) Neurosurgery , vol.11 , pp. 64-67
    • Grundy, B.L.1    Nelson, P.B.2    Lina, A.3    Heros, R.C.4
  • 58
    • 0023133572 scopus 로고
    • Electrophysiological monitoring during basilar aneurysm operation
    • Little J.R., Lesser R.P., Luders H. Electrophysiological monitoring during basilar aneurysm operation. Neurosurgery. 20:1987;421-427.
    • (1987) Neurosurgery , vol.20 , pp. 421-427
    • Little, J.R.1    Lesser, R.P.2    Luders, H.3
  • 59
    • 0028330845 scopus 로고
    • Evoked potential monitoring during posterior fossa aneurysm surgery: A comparison of two modalities
    • Manninen P.H., Patterson S., Lam A.M., Gelb A.W., Nantua W.E. Evoked potential monitoring during posterior fossa aneurysm surgery: a comparison of two modalities. Can J Anaesth. 41:1994;92-97.
    • (1994) Can J Anaesth , vol.41 , pp. 92-97
    • Manninen, P.H.1    Patterson, S.2    Lam, A.M.3    Gelb, A.W.4    Nantua, W.E.5
  • 60
    • 0005415220 scopus 로고
    • Identification of the sensorimotor cortex with SSEP phase reversal
    • C.M. Loftus, & V.C. Traynelis. New York: McGraw-Hill
    • Robertson S.C., Traynelis V.C., Yamada T.T. Identification of the sensorimotor cortex with SSEP phase reversal. Loftus C.M., Traynelis V.C. Intraoperative monitoring techniques in neurosurgery. 1994;107-111 McGraw-Hill, New York.
    • (1994) Intraoperative Monitoring Techniques in Neurosurgery , pp. 107-111
    • Robertson, S.C.1    Traynelis, V.C.2    Yamada, T.T.3
  • 62
    • 0027135366 scopus 로고
    • Balloon occlusion test of the internal carotid artery for evaluating resectability of blood vessel infiltrating cervical metastasis of advanced head and neck cancers - Heidelberg experience
    • Dietz A., von Kummer R., Adams H.P., et al. Balloon occlusion test of the internal carotid artery for evaluating resectability of blood vessel infiltrating cervical metastasis of advanced head and neck cancers - Heidelberg experience. Laryngorhinootologie. 72:1993;558-567.
    • (1993) Laryngorhinootologie , vol.72 , pp. 558-567
    • Dietz, A.1    Von Kummer, R.2    Adams, H.P.3
  • 63
    • 0027183710 scopus 로고
    • Monitoring carotid test occlusions with continuous EEG and clinical examination
    • Cloughesy T.F., Nuwer M.R., Hoch D., et al. Monitoring carotid test occlusions with continuous EEG and clinical examination. J Clin Neurophysiol. 10:1993;363-369.
    • (1993) J Clin Neurophysiol , vol.10 , pp. 363-369
    • Cloughesy, T.F.1    Nuwer, M.R.2    Hoch, D.3
  • 64
    • 0029014930 scopus 로고
    • EEG monitoring during endovascular embolization of cerebral arteriovenous malformations
    • Paiva T., Campos J., Baeta E., et al. EEG monitoring during endovascular embolization of cerebral arteriovenous malformations. Electroencephalogr Clin Neurophysiol. 95:1995;3-13.
    • (1995) Electroencephalogr Clin Neurophysiol , vol.95 , pp. 3-13
    • Paiva, T.1    Campos, J.2    Baeta, E.3
  • 65
    • 0011243906 scopus 로고
    • Pharmacologic effects of anesthesia on intraoperative neurophysiologic monitoring
    • G.B. Russell, & L.D. Rodichok. Boston: Butterworth-Heinemann
    • Russell G.B., Allen G.C., Jones J.L. Pharmacologic effects of anesthesia on intraoperative neurophysiologic monitoring. Russell G.B., Rodichok L.D. Primer of intraoperative neurophysiologic monitoring. 1995;227-240 Butterworth-Heinemann, Boston.
    • (1995) Primer of Intraoperative Neurophysiologic Monitoring , pp. 227-240
    • Russell, G.B.1    Allen, G.C.2    Jones, J.L.3
  • 66
    • 0023005960 scopus 로고
    • Effects of thiopental, fentanyl and etomidate on upper extremity somatosensory evoked potentials in humans
    • McPherson R.W., Sell B., Traystman R.J. Effects of thiopental, fentanyl and etomidate on upper extremity somatosensory evoked potentials in humans. Anesthesiology. 65:1986;584-589.
    • (1986) Anesthesiology , vol.65 , pp. 584-589
    • McPherson, R.W.1    Sell, B.2    Traystman, R.J.3
  • 67
    • 0025066717 scopus 로고
    • Assessment: Intraoperative neurophysiology
    • Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Assessment: intraoperative neurophysiology. Neurology. 40:1990;1644-1646.
    • (1990) Neurology , vol.40 , pp. 1644-1646


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.