메뉴 건너뛰기




Volumn 36, Issue 1, 2004, Pages 176-186

Cardiac valve prosthesis flow performances measured by 2D and 3D-stereo particle image velocimetry

Author keywords

[No Author keywords available]

Indexed keywords

ANEMOMETERS; CARDIOLOGY; DECELERATION; FEEDBACK CONTROL; PHYSIOLOGY; PULSATILE FLOW; SHEAR STRESS;

EID: 1142264056     PISSN: 07234864     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00348-003-0693-y     Document Type: Conference Paper
Times cited : (25)

References (13)
  • 1
    • 0033761606 scopus 로고    scopus 로고
    • Multidimensional MR mapping of multiple components of velocity and acceleration by Fourier phase encoding with a small number of encoding steps
    • Bittoun J, Jolivet O, Herment A, Itti E, Durand E, Mousseaux E, Tasu JP (2000) Multidimensional MR mapping of multiple components of velocity and acceleration by Fourier phase encoding with a small number of encoding steps. Magn Reson Med 44:723-30
    • (2000) Magn Reson Med , vol.44 , pp. 723-730
    • Bittoun, J.1    Jolivet, O.2    Herment, A.3    Itti, E.4    Durand, E.5    Mousseaux, E.6    Tasu, J.P.7
  • 2
    • 0003309626 scopus 로고
    • Mechanical hemolysis in flowing blood
    • Fung YC (ed) Prentice-Hall, Englewood Cliffs, NJ
    • Blackshear PL (1972) Mechanical hemolysis in flowing blood. In: Fung YC (ed) Biomechanics: its foundation and objectives. Prentice-Hall, Englewood Cliffs, NJ
    • (1972) Biomechanics: Its Foundation and Objectives
    • Blackshear, P.L.1
  • 3
    • 0031120342 scopus 로고    scopus 로고
    • Dual-camera DPIV for flow studies past artificial heart valves
    • Brucker C (1997) Dual-camera DPIV for flow studies past artificial heart valves. Exp Fluids 22,6:496-506
    • (1997) Exp Fluids , vol.22 , Issue.6 , pp. 496-506
    • Brucker, C.1
  • 4
    • 0034859627 scopus 로고    scopus 로고
    • Development of an experimental test bench for the measurement of fluid dynamic behaviour of mechanical heart valves
    • January 2001, San Jose, USA
    • Castellini P, Pinotti M, Scalise L (2001) Development of an experimental test bench for the measurement of fluid dynamic behaviour of mechanical heart valves. Proc SPIE 4263, January 2001, San Jose, USA, pp 65-72
    • (2001) Proc SPIE 4263 , pp. 65-72
    • Castellini, P.1    Pinotti, M.2    Scalise, L.3
  • 5
    • 0036421371 scopus 로고    scopus 로고
    • Vibration measurement on an artificial heart valve by laser Doppler vibrometry
    • June 2002, Ancona, Italy
    • Castellini P, Hubner R, Pinotti M (2002) Vibration measurement on an artificial heart valve by laser Doppler vibrometry. Proc SPIE 4827, June 2002, Ancona, Italy, pp 159-167
    • (2002) Proc SPIE , vol.4827 , pp. 159-167
    • Castellini, P.1    Hubner, R.2    Pinotti, M.3
  • 6
    • 0035063176 scopus 로고    scopus 로고
    • The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves
    • Grigioni M, Daniele C, D'Avenio G, Barbaro V (2001) The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves. J Biomechanics 34:613-621
    • (2001) J Biomechanics , vol.34 , pp. 613-621
    • Grigioni, M.1    Daniele, C.2    D'Avenio, G.3    Barbaro, V.4
  • 7
    • 0003267614 scopus 로고
    • Bileaflet valves
    • Bodnar E, Freater R (eds). McGraw-Hill, New York
    • Horstkotte D, Bodnar E (1992) Bileaflet valves. In: Bodnar E, Freater R (eds) Replacement cardiac valves. McGraw-Hill, New York, pp 201-228
    • (1992) Replacement Cardiac Valves , pp. 201-228
    • Horstkotte, D.1    Bodnar, E.2
  • 9
    • 0033490803 scopus 로고    scopus 로고
    • Development of a flow feedback pulse duplicator system with rhesus monkey arterial input impedance characteristics
    • Jeremy D, Schaub JD, Koenig SC, Schroeder MJ, Ewert DL, Drew GA, Swope RD (1999) Development of a flow feedback pulse duplicator system with rhesus monkey arterial input impedance characteristics. ASAIO Journal 45,4:334-339
    • (1999) ASAIO Journal , vol.45 , Issue.4 , pp. 334-339
    • Jeremy, D.1    Schaub, J.D.2    Koenig, S.C.3    Schroeder, M.J.4    Ewert, D.L.5    Drew, G.A.6    Swope, R.D.7
  • 10
    • 0027991718 scopus 로고
    • Particle-image-velocimetry in the investigation of flow past artificial heart valves
    • Lim WL, Chew YT, Low HT (1994) Particle-image-velocimetry in the investigation of flow past artificial heart valves. Ann Biomed Eng 22:307-318
    • (1994) Ann Biomed Eng , vol.22 , pp. 307-318
    • Lim, W.L.1    Chew, Y.T.2    Low, H.T.3
  • 11
    • 0000198669 scopus 로고    scopus 로고
    • Recent findings on flow induced blood damage: Critical shear stress and exposure times obtained with a high shear Couette-system
    • Paul R, Shugner F, Reul H, Rau G (1999) Recent findings on flow induced blood damage: critical shear stress and exposure times obtained with a high shear Couette-system. Artificial Organs 23,7:680
    • (1999) Artificial Organs , vol.23 , Issue.7 , pp. 680
    • Paul, R.1    Shugner, F.2    Reul, H.3    Rau, G.4
  • 12
    • 1142272169 scopus 로고
    • Principle of fluid mechanics applied to some situations in the human circulation and particularly to testing of valves in a pulse duplicator
    • Temple LJ, Serafin R, Calvert NG, Drabble JM (1964) Principle of fluid mechanics applied to some situations in the human circulation and particularly to testing of valves in a pulse duplicator. Thorax 19:261
    • (1964) Thorax , vol.19 , pp. 261
    • Temple, L.J.1    Serafin, R.2    Calvert, N.G.3    Drabble, J.M.4
  • 13
    • 0015580040 scopus 로고
    • Pressure and flow generated by the left ventricule against different impedances
    • Westerhof N, Elzinga G (1973) Pressure and flow generated by the left ventricule against different impedances. Circulation Research 32:178-186
    • (1973) Circulation Research , vol.32 , pp. 178-186
    • Westerhof, N.1    Elzinga, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.