메뉴 건너뛰기




Volumn 112, Issue 1, 2005, Pages 67-72

Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics: Randomized clinical trial

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM; NEODYMIUM; YTTRIUM;

EID: 11344292633     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2004.07.032     Document Type: Article
Times cited : (87)

References (23)
  • 1
    • 0032424289 scopus 로고    scopus 로고
    • Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation
    • H. Hayashi, K. Hayashi, F. Nakao, F. Hayashi Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation Arch Ophthalmol 116 1998 1579 1582
    • (1998) Arch Ophthalmol , vol.116 , pp. 1579-1582
    • Hayashi, H.1    Hayashi, K.2    Nakao, F.3    Hayashi, F.4
  • 2
    • 0031899326 scopus 로고    scopus 로고
    • Relationship between intraocular lens biomaterials and posterior capsule opacification
    • P.G. Ursell, D.J. Spalton, M.V. Pande Relationship between intraocular lens biomaterials and posterior capsule opacification J Cataract Refract Surg 24 1998 352 360
    • (1998) J Cataract Refract Surg , vol.24 , pp. 352-360
    • Ursell, P.G.1    Spalton, D.J.2    Pande, M.V.3
  • 3
    • 0032622426 scopus 로고    scopus 로고
    • The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
    • E.J. Hollick, D.J. Spalton, P.G. Ursell The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery Ophthalmology 106 1999 49 54
    • (1999) Ophthalmology , vol.106 , pp. 49-54
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3
  • 4
    • 0034753434 scopus 로고    scopus 로고
    • Posterior capsule opacification with Acrysof and poly(methyl methacrylate) intraocular lenses: Comparative study with a 3-year follow-up
    • K. Sundelin, Y. Friberg-Riad, A. Ostberg, J. Sjostrand Posterior capsule opacification with Acrysof and poly(methyl methacrylate) intraocular lenses Comparative study with a 3-year follow-up J Cataract Refract Surg 27 2001 1586 1590
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1586-1590
    • Sundelin, K.1    Friberg-Riad, Y.2    Ostberg, A.3    Sjostrand, J.4
  • 5
    • 0034910337 scopus 로고    scopus 로고
    • Posterior capsule opacification and lens epithelial cell layer formation: Hydroview hydrogel versus Acrysof acrylic intraocular lenses
    • A. Scaramuzza, G.T. Fernando, B.B. Crayford Posterior capsule opacification and lens epithelial cell layer formation: Hydroview hydrogel versus Acrysof acrylic intraocular lenses J Cataract Refract Surg 27 2001 1047 1054
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1047-1054
    • Scaramuzza, A.1    Fernando, G.T.2    Crayford, B.B.3
  • 6
    • 0032895795 scopus 로고    scopus 로고
    • Posterior capsule opacification: Part 1: Experimental investigations
    • O. Nishi Posterior capsule opacification Part 1: experimental investigations J Cataract Refract Surg 25 1999 106 117
    • (1999) J Cataract Refract Surg , vol.25 , pp. 106-117
    • Nishi, O.1
  • 7
    • 0033497365 scopus 로고    scopus 로고
    • Update on fixation of rigid and foldable posterior chamber intraocular lenses: Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification
    • J. Ram, D.J. Apple, Q. Peng Update on fixation of rigid and foldable posterior chamber intraocular lenses Part II: choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification Ophthalmology 106 1999 891 900
    • (1999) Ophthalmology , vol.106 , pp. 891-900
    • Ram, J.1    Apple, D.J.2    Peng, Q.3
  • 8
    • 0033795702 scopus 로고    scopus 로고
    • Long-term results of the foldable CeeOn Edge intraocular lens
    • W.H. Schmack, K. Gerstmeyer Long-term results of the foldable CeeOn Edge intraocular lens J Cataract Refract Surg 26 2000 1172 1175
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1172-1175
    • Schmack, W.H.1    Gerstmeyer, K.2
  • 9
    • 0034003905 scopus 로고    scopus 로고
    • Two year results: Sharp versus rounded optic edges on silicone lenses
    • A.J. Kruger, J. Schauersberger, C. Abela Two year results: sharp versus rounded optic edges on silicone lenses J Cataract Refract Surg 26 2000 566 570
    • (2000) J Cataract Refract Surg , vol.26 , pp. 566-570
    • Kruger, A.J.1    Schauersberger, J.2    Abela, C.3
  • 10
    • 0036166274 scopus 로고    scopus 로고
    • Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification
    • W. Buehl, O. Findl, R. Menapace Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification J Cataract Refract Surg 28 2002 265 270
    • (2002) J Cataract Refract Surg , vol.28 , pp. 265-270
    • Buehl, W.1    Findl, O.2    Menapace, R.3
  • 11
    • 0036169815 scopus 로고    scopus 로고
    • Assessment of anterior capsule opacification: Photographic technique and quantification
    • S. Sacu, O. Findl, R. Menapace Assessment of anterior capsule opacification: photographic technique and quantification J Cataract Refract Surg 28 2002 271 275
    • (2002) J Cataract Refract Surg , vol.28 , pp. 271-275
    • Sacu, S.1    Findl, O.2    Menapace, R.3
  • 12
    • 0037257792 scopus 로고    scopus 로고
    • Comparison of 4 methods for quantifying posterior capsule opacification
    • O. Findl, W. Buehl, R. Menapace Comparison of 4 methods for quantifying posterior capsule opacification J Cataract Refract Surg 29 2003 106 111
    • (2003) J Cataract Refract Surg , vol.29 , pp. 106-111
    • Findl, O.1    Buehl, W.2    Menapace, R.3
  • 15
    • 0035319373 scopus 로고    scopus 로고
    • Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification
    • O. Nishi, K. Nishi, J. Akura, T. Nagata Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification J Cataract Refract Surg 27 2001 608 613
    • (2001) J Cataract Refract Surg , vol.27 , pp. 608-613
    • Nishi, O.1    Nishi, K.2    Akura, J.3    Nagata, T.4
  • 16
    • 0031817140 scopus 로고    scopus 로고
    • Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens
    • O. Nishi, K. Nishi, K. Sakanishi Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens Ophthalmic Surg Lasers 29 1998 587 594
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 587-594
    • Nishi, O.1    Nishi, K.2    Sakanishi, K.3
  • 17
    • 0036062059 scopus 로고    scopus 로고
    • Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    • W. Buehl, O. Findl, R. Menapace Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification J Cataract Refract Surg 28 2002 1105 1111
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1105-1111
    • Buehl, W.1    Findl, O.2    Menapace, R.3
  • 18
    • 0037398513 scopus 로고    scopus 로고
    • Quantification of posterior capsule opacification with round and sharp edge intraocular lenses
    • G.U. Auffarth, A. Golescu, K.A. Becker, H.E. Volcker Quantification of posterior capsule opacification with round and sharp edge intraocular lenses Ophthalmology 110 2003 772 780
    • (2003) Ophthalmology , vol.110 , pp. 772-780
    • Auffarth, G.U.1    Golescu, A.2    Becker, K.A.3    Volcker, H.E.4
  • 19
    • 1842528952 scopus 로고    scopus 로고
    • Influence of optic edge design and anterior capsule polishing on posterior capsule fibrosis
    • S. Sacu, R. Menapace, O. Findl Influence of optic edge design and anterior capsule polishing on posterior capsule fibrosis J Cataract Refract Surg 30 2004 658 662
    • (2004) J Cataract Refract Surg , vol.30 , pp. 658-662
    • Sacu, S.1    Menapace, R.2    Findl, O.3
  • 20
    • 0037254363 scopus 로고    scopus 로고
    • Adhesion of soluble fibronectin, vitronectin, and collagen type IV to intraocular lens materials
    • R.J. Linnola, M. Sund, R. Ylonen, T. Pihlajaniemi Adhesion of soluble fibronectin, vitronectin, and collagen type IV to intraocular lens materials J Cataract Refract Surg 29 2003 146 152
    • (2003) J Cataract Refract Surg , vol.29 , pp. 146-152
    • Linnola, R.J.1    Sund, M.2    Ylonen, R.3    Pihlajaniemi, T.4
  • 21
    • 11344258797 scopus 로고    scopus 로고
    • Assessment of capsule closure after cataract surgery using optical coherence tomography
    • In press.
    • Sacu S, Findl O, Linnola RJ. Assessment of capsule closure after cataract surgery using optical coherence tomography. J Cataract Refract Surg. In press.
    • J Cataract Refract Surg
    • Sacu, S.1    Findl, O.2    Linnola, R.J.3
  • 22
    • 0041856088 scopus 로고    scopus 로고
    • Posterior capsule opacification after phacoemulsification: Silicone CeeOn Edge versus acrylate Acrysof intraocular lens
    • G. Prosdocimo, G. Tassinari, M. Sala Posterior capsule opacification after phacoemulsification: silicone CeeOn Edge versus acrylate Acrysof intraocular lens J Cataract Refract Surg 29 2003 1551 1555
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1551-1555
    • Prosdocimo, G.1    Tassinari, G.2    Sala, M.3
  • 23
    • 0034764597 scopus 로고    scopus 로고
    • Comparison of the biocompatibility of 2 foldable intraocular lenses with sharp optic edges
    • J. Schauersberger, M. Amon, A. Kruger Comparison of the biocompatibility of 2 foldable intraocular lenses with sharp optic edges J Cataract Refract Surg 27 2001 1579 1585
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1579-1585
    • Schauersberger, J.1    Amon, M.2    Kruger, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.