메뉴 건너뛰기




Volumn 21, Issue 4, 2004, Pages 247-258

Percutaneous transthoracic needle biopsy: Special considerations and techniques used in lung transplant recipients

Author keywords

Interventional radiology; Lung transplant; Transthoracic needle biopsy

Indexed keywords

AIR EMBOLISM; BLEEDING; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; ECHOGRAPHY; FLUOROSCOPY; HEMOPTYSIS; HUMAN; LUNG BIOPSY; LUNG HEMORRHAGE; LUNG INJURY; LUNG NODULE; LUNG PARENCHYMA; LUNG TRANSPLANTATION; NEEDLE BIOPSY; PERCUTANEOUS BIOPSY; PNEUMOTHORAX; REVIEW; RISK FACTOR; TRANSBRONCHIAL BIOPSY; TREATMENT CONTRAINDICATION;

EID: 11344277054     PISSN: 07399529     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-861559     Document Type: Review
Times cited : (10)

References (52)
  • 2
    • 0035043419 scopus 로고    scopus 로고
    • Percutaneous needle biopsy of the lung and its impact on patient management
    • Murphy JM, Gleeson FV, Flower CD. Percutaneous needle biopsy of the lung and its impact on patient management. World J Surg 2001;25:373-380
    • (2001) World J Surg , vol.25 , pp. 373-380
    • Murphy, J.M.1    Gleeson, F.V.2    Flower, C.D.3
  • 4
    • 0036088680 scopus 로고    scopus 로고
    • Bronchogenic carcinoma after lung transplantation: Frequency, clinical characteristics, and imaging findings
    • Collins J, Kazerooni EA, Lacomis J, et al. Bronchogenic carcinoma after lung transplantation: frequency, clinical characteristics, and imaging findings. Radiology 2002;224:131-138
    • (2002) Radiology , vol.224 , pp. 131-138
    • Collins, J.1    Kazerooni, E.A.2    Lacomis, J.3
  • 5
    • 0035127173 scopus 로고    scopus 로고
    • Lung transplantation at the turn of the century
    • DeMeo DL, Ginns LC. Lung transplantation at the turn of the century. Annu Rev Med 2001;52:185-201
    • (2001) Annu Rev Med , vol.52 , pp. 185-201
    • DeMeo, D.L.1    Ginns, L.C.2
  • 6
    • 0025861042 scopus 로고
    • The value of negative needle biopsy in suspected operable lung cancer
    • Charig MJ, Stutley JE, Padley SPG, et al. The value of negative needle biopsy in suspected operable lung cancer. Clin Radiol 1991;44(3):147-149
    • (1991) Clin Radiol , vol.44 , Issue.3 , pp. 147-149
    • Charig, M.J.1    Stutley, J.E.2    Padley, S.P.G.3
  • 7
    • 0018384981 scopus 로고
    • Etiologic diagnosis of focal pulmonary infection in immunocompromised patients by fluoroscopically guided percutaneous needle aspiration
    • Castellino RA, Blank N. Etiologic diagnosis of focal pulmonary infection in immunocompromised patients by fluoroscopically guided percutaneous needle aspiration. Radiology 1979;132:563-567
    • (1979) Radiology , vol.132 , pp. 563-567
    • Castellino, R.A.1    Blank, N.2
  • 8
    • 0024578778 scopus 로고
    • Transthoracic aspiration needle biopsy: Value in the diagnosis of pulmonary infections
    • Conces DJ, Clark SA, Tarver RD, et al. Transthoracic aspiration needle biopsy: value in the diagnosis of pulmonary infections. AJR Am J Roentgenol 1989;152:31-34
    • (1989) AJR Am J Roentgenol , vol.152 , pp. 31-34
    • Conces, D.J.1    Clark, S.A.2    Tarver, R.D.3
  • 9
    • 0036891927 scopus 로고    scopus 로고
    • CT-guided percutaneous fine-needle aspiration biopsy of small (< or = 1-cm) pulmonary lesions
    • Wallace MJ, Krishnamurthy S, Broemeling LD, et al. CT-guided percutaneous fine-needle aspiration biopsy of small (< or = 1-cm) pulmonary lesions. Radiology 2002;225:823-828
    • (2002) Radiology , vol.225 , pp. 823-828
    • Wallace, M.J.1    Krishnamurthy, S.2    Broemeling, L.D.3
  • 10
    • 0030937778 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy of small solitary pulmonary nodules
    • Yankelevitz DF, Henschke CI, Koizumi JH, et al. CT-guided transthoracic needle biopsy of small solitary pulmonary nodules. Clin Imaging 1997;21:107-110
    • (1997) Clin Imaging , vol.21 , pp. 107-110
    • Yankelevitz, D.F.1    Henschke, C.I.2    Koizumi, J.H.3
  • 11
    • 0036119579 scopus 로고    scopus 로고
    • Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy
    • Froelich JJ, Ishaque N, Regn J, et al. Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy. Eur J Radiol 2002;42:74-79
    • (2002) Eur J Radiol , vol.42 , pp. 74-79
    • Froelich, J.J.1    Ishaque, N.2    Regn, J.3
  • 12
    • 0029832236 scopus 로고    scopus 로고
    • Guidance with real-time CT fluoroscopy: Early clinical experience
    • Katada K, Kato R, Anno H, et al. Guidance with real-time CT fluoroscopy: early clinical experience. Radiology 1996;200:851-856
    • (1996) Radiology , vol.200 , pp. 851-856
    • Katada, K.1    Kato, R.2    Anno, H.3
  • 13
    • 0031877298 scopus 로고    scopus 로고
    • Technical aspects of needle aspiration lung biopsy: A personal perspective
    • Moore EH. Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 1998;208:303-318
    • (1998) Radiology , vol.208 , pp. 303-318
    • Moore, E.H.1
  • 14
    • 0029970058 scopus 로고    scopus 로고
    • Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: Comparison of small and large pulmonary nodules
    • Li H, Boiselle PM, Shepard JO. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 1996;167:105-109
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 105-109
    • Li, H.1    Boiselle, P.M.2    Shepard, J.O.3
  • 15
    • 0029064627 scopus 로고
    • CT-guided automated needle biopsy of the chest
    • Haramati LB. CT-guided automated needle biopsy of the chest. AJR Am J Roentgenol 1995;165:53-55
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 53-55
    • Haramati, L.B.1
  • 16
    • 0032565880 scopus 로고    scopus 로고
    • Percutaneous core cutting needle biopsy compared with fine-needle aspiration in the diagnosis of peripheral lung malignant lesions: Results in 156 patients
    • Greif J, Marmur S, Schwarz Y, et al. Percutaneous core cutting needle biopsy compared with fine-needle aspiration in the diagnosis of peripheral lung malignant lesions: results in 156 patients. Cancer 1998;84:144-147
    • (1998) Cancer , vol.84 , pp. 144-147
    • Greif, J.1    Marmur, S.2    Schwarz, Y.3
  • 18
    • 0030051348 scopus 로고    scopus 로고
    • Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients
    • Klein JS, Salomon G, Stewart EA. Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 1996;198:715-720
    • (1996) Radiology , vol.198 , pp. 715-720
    • Klein, J.S.1    Salomon, G.2    Stewart, E.A.3
  • 19
    • 0032879480 scopus 로고    scopus 로고
    • Percutaneous core needle biopsy vs. fine-needle aspiration in diagnosing benign lung lesions
    • Greif J, Marmur S, Schwarz Y, et al. Percutaneous core needle biopsy vs. fine-needle aspiration in diagnosing benign lung lesions. Acta Cytol 1999;43:756-760
    • (1999) Acta Cytol , vol.43 , pp. 756-760
    • Greif, J.1    Marmur, S.2    Schwarz, Y.3
  • 20
    • 0031749803 scopus 로고    scopus 로고
    • Additional information from percutaneous cutting needle biopsy following fine-needle aspiration in the diagnosis of chest lesions
    • Staroselsky AN, Schwarz Y, Man A, et al. Additional information from percutaneous cutting needle biopsy following fine-needle aspiration in the diagnosis of chest lesions. Chest 1998;113:1522-1525
    • (1998) Chest , vol.113 , pp. 1522-1525
    • Staroselsky, A.N.1    Schwarz, Y.2    Man, A.3
  • 21
    • 0032085090 scopus 로고    scopus 로고
    • Should cutting needles replace needle aspiration of lung lesions?
    • McLoud TC. Should cutting needles replace needle aspiration of lung lesions? Radiology 1998;207:569-570
    • (1998) Radiology , vol.207 , pp. 569-570
    • McLoud, T.C.1
  • 22
    • 0034028417 scopus 로고    scopus 로고
    • Special techniques in transthoracic needle biopsy of pulmonary nodules
    • Yankelevitz DF, Vazquez M, Henschke CI. Special techniques in transthoracic needle biopsy of pulmonary nodules. Radiol Clin North Am 2000;38:267-279
    • (2000) Radiol Clin North Am , vol.38 , pp. 267-279
    • Yankelevitz, D.F.1    Vazquez, M.2    Henschke, C.I.3
  • 23
    • 0026320314 scopus 로고
    • Complications after CT-guided needle biopsy through aerated versus nonaerated lung
    • Haramati LB, Austin JHM. Complications after CT-guided needle biopsy through aerated versus nonaerated lung. Radiology 1991;181:778
    • (1991) Radiology , vol.181 , pp. 778
    • Haramati, L.B.1    Austin, J.H.M.2
  • 24
    • 0027157586 scopus 로고
    • CT gantry tilt: Utility in transthoracic fine-needle aspiration biopsy
    • Stern EJ, Webb WR, Gamsu G. CT gantry tilt: utility in transthoracic fine-needle aspiration biopsy. Radiology 1993;187:873-874
    • (1993) Radiology , vol.187 , pp. 873-874
    • Stern, E.J.1    Webb, W.R.2    Gamsu, G.3
  • 25
    • 0027200789 scopus 로고
    • Percutaneous CT biopsy of chest lesions: An in vitro analysis of the effect of partial volume averaging on needle positioning
    • Yankelevitz DF, Henschke CI, Davis SD. Percutaneous CT biopsy of chest lesions: an in vitro analysis of the effect of partial volume averaging on needle positioning. AJR Am J Roentgenol 1993;161:273-278
    • (1993) AJR Am J Roentgenol , vol.161 , pp. 273-278
    • Yankelevitz, D.F.1    Henschke, C.I.2    Davis, S.D.3
  • 27
    • 0027216494 scopus 로고
    • CT-guided large-bore biopsy: Extrapleural injection of saline for safe transpleural access to pulmonary lesions
    • Klose KC. CT-guided large-bore biopsy: extrapleural injection of saline for safe transpleural access to pulmonary lesions. Cardiovasc Intervent Radiol 1993;16:259-261
    • (1993) Cardiovasc Intervent Radiol , vol.16 , pp. 259-261
    • Klose, K.C.1
  • 29
    • 0029859734 scopus 로고    scopus 로고
    • Needle-tip repositioning during computed-tomography-guided transthoracic needle aspiration biopsy of small deep pulmonary lesions: Minor adjustments make a big difference
    • Yankelevitz DF, Davis SD, Chiarella D, et al. Needle-tip repositioning during computed-tomography-guided transthoracic needle aspiration biopsy of small deep pulmonary lesions: minor adjustments make a big difference. J Thorac Imaging 1996;11:279-282
    • (1996) J Thorac Imaging , vol.11 , pp. 279-282
    • Yankelevitz, D.F.1    Davis, S.D.2    Chiarella, D.3
  • 30
    • 0032843829 scopus 로고    scopus 로고
    • Radiologically determined diameter, pathologic diameter, and reactive zone surrounding pulmonary neoplasms: Implications for transthoracic fine-needle aspiration of pulmonary neoplasms
    • Layfield LJ, Liu K, Erasmus JJ. Radiologically determined diameter, pathologic diameter, and reactive zone surrounding pulmonary neoplasms: implications for transthoracic fine-needle aspiration of pulmonary neoplasms. Diagn Cytopathol 1999;21:250-252
    • (1999) Diagn Cytopathol , vol.21 , pp. 250-252
    • Layfield, L.J.1    Liu, K.2    Erasmus, J.J.3
  • 31
    • 0025331754 scopus 로고
    • Positional precautions in needle aspiration lung biopsy
    • Moore EH, Shepard JO, McLoud TC, et al. Positional precautions in needle aspiration lung biopsy. Radiology 1990;175:733-735
    • (1990) Radiology , vol.175 , pp. 733-735
    • Moore, E.H.1    Shepard, J.O.2    McLoud, T.C.3
  • 32
    • 0019304724 scopus 로고
    • Transthoracic needle biopsy: Accuracy and complications in relation to location and type of lesion
    • Berquist TH, Bailey PB, Cortese DA, et al. Transthoracic needle biopsy: accuracy and complications in relation to location and type of lesion. Mayo Clin Proc 1980;55:475-481
    • (1980) Mayo Clin Proc , vol.55 , pp. 475-481
    • Berquist, T.H.1    Bailey, P.B.2    Cortese, D.A.3
  • 33
    • 0023547116 scopus 로고
    • Postbiopsy pneumothorax: Estimating the risk by chest radiography and pulmonary function tests
    • Fish GD, Stanley JH, Miller S, et al. Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests. AJR Am J Roentgenol 1988;150: 71-74
    • (1988) AJR Am J Roentgenol , vol.150 , pp. 71-74
    • Fish, G.D.1    Stanley, J.H.2    Miller, S.3
  • 34
    • 0029787293 scopus 로고    scopus 로고
    • Aspiration of a large pneumothorax resulting from transthoracic needle biopsy
    • Yankelevitz DF, Davis SD, Henschke CI. Aspiration of a large pneumothorax resulting from transthoracic needle biopsy. Radiology 1996;200:695-697
    • (1996) Radiology , vol.200 , pp. 695-697
    • Yankelevitz, D.F.1    Davis, S.D.2    Henschke, C.I.3
  • 35
    • 0036212166 scopus 로고    scopus 로고
    • Management of pneumothorax after percutaneous CT-guided lung biopsy
    • Yamagami T, Nakamura T, Iida S, et al. Management of pneumothorax after percutaneous CT-guided lung biopsy. Chest 2002;121:1159-1164
    • (2002) Chest , vol.121 , pp. 1159-1164
    • Yamagami, T.1    Nakamura, T.2    Iida, S.3
  • 36
    • 0033917474 scopus 로고    scopus 로고
    • Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy
    • Lang EK, Ghavami R, Schreiner VC, et al. Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy. Radiology 2000;216:93-96
    • (2000) Radiology , vol.216 , pp. 93-96
    • Lang, E.K.1    Ghavami, R.2    Schreiner, V.C.3
  • 37
    • 0025324874 scopus 로고
    • Usefulness of the blood patch technique after transthoracic needle aspiration biopsy
    • Herman SJ, Weisbrod GL. Usefulness of the blood patch technique after transthoracic needle aspiration biopsy. Radiology 1990;176:395-397
    • (1990) Radiology , vol.176 , pp. 395-397
    • Herman, S.J.1    Weisbrod, G.L.2
  • 38
    • 0026774694 scopus 로고
    • Pneumothorax after lung biopsy: Prevention with transpleural placement of compressed collagen foam plugs
    • Engeler CE, Hunter DW, Castaneda-Zuniga W, et al. Pneumothorax after lung biopsy: prevention with transpleural placement of compressed collagen foam plugs. Radiology 1992;184:787-789
    • (1992) Radiology , vol.184 , pp. 787-789
    • Engeler, C.E.1    Hunter, D.W.2    Castaneda-Zuniga, W.3
  • 39
    • 0031991482 scopus 로고    scopus 로고
    • Case report: Cardiac tamponade following fine needle aspiration (FNA) of a mediastinal mass
    • Man A, Schwarz Y, Greif J. Case report: cardiac tamponade following fine needle aspiration (FNA) of a mediastinal mass. Clin Radiol 1998;53:151-152
    • (1998) Clin Radiol , vol.53 , pp. 151-152
    • Man, A.1    Schwarz, Y.2    Greif, J.3
  • 40
    • 0018381220 scopus 로고
    • Fatal intrathoracic hemorrhage after percutaneous aspiration lung biopsy
    • Milner LB, Ryan K, Gullo J. Fatal intrathoracic hemorrhage after percutaneous aspiration lung biopsy. AJR Am J Roentgenol 1979;132:280-281
    • (1979) AJR Am J Roentgenol , vol.132 , pp. 280-281
    • Milner, L.B.1    Ryan, K.2    Gullo, J.3
  • 41
    • 22644448256 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration
    • Arakawa H, Nakajima Y, Kurihara H, et al. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol 1996;51:503-506
    • (1996) Clin Radiol , vol.51 , pp. 503-506
    • Arakawa, H.1    Nakajima, Y.2    Kurihara, H.3
  • 42
    • 0023637433 scopus 로고
    • Fatal systemic arterial air embolism following lung needle aspiration
    • Aberle DR, Gamsu G, Golden JA. Fatal systemic arterial air embolism following lung needle aspiration. Radiology 1987;165:351-353
    • (1987) Radiology , vol.165 , pp. 351-353
    • Aberle, D.R.1    Gamsu, G.2    Golden, J.A.3
  • 43
    • 0022005570 scopus 로고
    • Cerebral air embolism resulting from invasive medical procedures: Treatment and hyperbaric oxygen
    • Murphy BP, Harford FJ, Cramer FS. Cerebral air embolism resulting from invasive medical procedures: treatment and hyperbaric oxygen. Ann Surg 1985;201:242-245
    • (1985) Ann Surg , vol.201 , pp. 242-245
    • Murphy, B.P.1    Harford, F.J.2    Cramer, F.S.3
  • 45
    • 0021997060 scopus 로고
    • Transthoracic needle aspiration biopsy of benign and malignant lung lesions
    • Khouri NF, Stitik FP, Erozan YS, et al. Transthoracic needle aspiration biopsy of benign and malignant lung lesions. AJR Am J Roentgenol 1985;144:281-288
    • (1985) AJR Am J Roentgenol , vol.144 , pp. 281-288
    • Khouri, N.F.1    Stitik, F.P.2    Erozan, Y.S.3
  • 46
    • 0026637980 scopus 로고
    • Inter-institutional database for comparison of performance in lung fine-needle aspiration cytology: A College of American Pathologists Q-probe study of 5264 cases with histologic correlation
    • Zarbo RJ, Fenoglio-Presier CM. Inter-institutional database for comparison of performance in lung fine-needle aspiration cytology: a College of American Pathologists Q-probe study of 5264 cases with histologic correlation. Arch Pathol Lab Med 1992;116:463-470
    • (1992) Arch Pathol Lab Med , vol.116 , pp. 463-470
    • Zarbo, R.J.1    Fenoglio-Presier, C.M.2
  • 47
    • 0031030126 scopus 로고    scopus 로고
    • Transthoracic needle biopsy of small pulmonary nodules
    • Westcott JL, Najmussaqib R, Colley DP. Transthoracic needle biopsy of small pulmonary nodules. Radiology 1997;202:97-103
    • (1997) Radiology , vol.202 , pp. 97-103
    • Westcott, J.L.1    Najmussaqib, R.2    Colley, D.P.3
  • 48
    • 0031052374 scopus 로고    scopus 로고
    • Middle mediastinal lesions: Preliminary experience with CT-guided fine-needle aspiration biopsy with a supra-sternal approach
    • Belfiore G, Camera L, Moggio G, et al. Middle mediastinal lesions: preliminary experience with CT-guided fine-needle aspiration biopsy with a supra-sternal approach. Radiology 1997;202:870-873
    • (1997) Radiology , vol.202 , pp. 870-873
    • Belfiore, G.1    Camera, L.2    Moggio, G.3
  • 49
    • 0029930175 scopus 로고    scopus 로고
    • Transthoracic needle biopsy of mediastinal lymph nodes for staging lung and other cancers
    • Protopapas Z, Westcott JL. Transthoracic needle biopsy of mediastinal lymph nodes for staging lung and other cancers. Radiology 1996;199:489-496
    • (1996) Radiology , vol.199 , pp. 489-496
    • Protopapas, Z.1    Westcott, J.L.2
  • 50
    • 0025141483 scopus 로고
    • Yield of percutaneous needle lung aspiration in lung abscess
    • Grinan NP, Lucena FM, Romero JV, et al. Yield of percutaneous needle lung aspiration in lung abscess. Chest 1990;97:69-74
    • (1990) Chest , vol.97 , pp. 69-74
    • Grinan, N.P.1    Lucena, F.M.2    Romero, J.V.3
  • 51
    • 0027495723 scopus 로고
    • Percutaneous transthoracic needle biopsy in AIDS: Analysis in 32 patients
    • Gruden JF, Klein JS, Webb WR. Percutaneous transthoracic needle biopsy in AIDS: analysis in 32 patients. Radiology 1993;189:567-571
    • (1993) Radiology , vol.189 , pp. 567-571
    • Gruden, J.F.1    Klein, J.S.2    Webb, W.R.3
  • 52
    • 0025783868 scopus 로고
    • Focal pulmonary lesions in patients with AIDS: Percutaneous transthoracic needle biopsy
    • Scott WW, Kuhlman JE. Focal pulmonary lesions in patients with AIDS: percutaneous transthoracic needle biopsy. Radiology 1991;180:419-421
    • (1991) Radiology , vol.180 , pp. 419-421
    • Scott, W.W.1    Kuhlman, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.