메뉴 건너뛰기




Volumn 124, Issue 10, 2004, Pages 688-691

Management of intra-articular fractures of the proximal interphalangeal joint by internal fixation and bone grafting

Author keywords

Bone grafting; DASH Score; Internal fixation; Intra articular fracture; Proximal interphalangeal joint

Indexed keywords

ADULT; ARTICLE; BONE SCREW; BONE TRANSPLANTATION; CASE REPORT; DIAPHYSIS; FINGER FRACTURE; FOLLOW UP; FRACTURE EXTERNAL FIXATION; HUMAN; INTRAARTICULAR FRACTURE; JOINT MOBILITY; JOINT RADIOGRAPHY; MALE; MEDICAL LITERATURE; MOBILIZATION; OSTEOSYNTHESIS; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; PROXIMAL INTERPHALANGEAL JOINT; RADIUS; SCORING SYSTEM; SURGICAL TECHNIQUE; TREATMENT OUTCOME;

EID: 11244337344     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-004-0758-2     Document Type: Article
Times cited : (10)

References (24)
  • 1
    • 0023146034 scopus 로고
    • Unstable fracture dislocation of the proximal interphalangeal joint: Treatment with a force couple splint
    • Agee JM (1987) Unstable fracture dislocation of the proximal interphalangeal joint: Treatment with a force couple splint. Clin Orthop 214:101-112
    • (1987) Clin. Orthop. , vol.214 , pp. 101-112
    • Agee, J.M.1
  • 2
    • 0029948933 scopus 로고    scopus 로고
    • Fractures of the base of the middle phalanx treated by a dynamic external fixation device
    • Allison DM (1996) Fractures of the base of the middle phalanx treated by a dynamic external fixation device. J Hand Surg Br 21:305-310
    • (1996) J. Hand Surg. Br. , vol.21 , pp. 305-310
    • Allison, D.M.1
  • 3
  • 5
    • 0028335240 scopus 로고
    • Mechanical requirements for application and modification of the dynamic force couple method
    • Buchanan RT (1994) Mechanical requirements for application and modification of the dynamic force couple method. Hand Clin 10:221-228
    • (1994) Hand Clin. , vol.10 , pp. 221-228
    • Buchanan, R.T.1
  • 6
    • 0002845036 scopus 로고
    • Management of proximal interphalangeal joint fractures using a new dynamic traction splint and early active movements
    • Dennys LJ, Hurst LN, Cox J (1992) Management of proximal interphalangeal joint fractures using a new dynamic traction splint and early active movements. J Hand Therapy 1:16-24
    • (1992) J. Hand Therapy , vol.1 , pp. 16-24
    • Dennys, L.J.1    Hurst, L.N.2    Cox, J.3
  • 8
    • 0018827181 scopus 로고
    • Volar plate arthroplasty of the proximal interphalangeal joint: A review of ten year's experience
    • Eaton RG, Malerich MM (1980) Volar plate arthroplasty of the proximal interphalangeal joint: A review of ten year's experience. J Hand Surg 5:260-268
    • (1980) J. Hand Surg. , vol.5 , pp. 260-268
    • Eaton, R.G.1    Malerich, M.M.2
  • 9
    • 0025143663 scopus 로고
    • The Stockport Serpentine Spring System for the treatment of displaced comminuted intra-articular phalangeal fractures
    • Fahmy NR (1990) The Stockport Serpentine Spring System for the treatment of displaced comminuted intra-articular phalangeal fractures. J Hand Surg Br 15:303-311
    • (1990) J. Hand Surg. Br. , vol.15 , pp. 303-311
    • Fahmy, N.R.1
  • 10
    • 0032185750 scopus 로고    scopus 로고
    • Fracture dislocation of the middle phalanx at the proximal interphalangeal joint: Repair with a simple intra-digital traction fixation device
    • Gaul JS, Rosenberg SN (1998) Fracture dislocation of the middle phalanx at the proximal interphalangeal joint: Repair with a simple intra-digital traction fixation device. Am J Orthop 27:682-688
    • (1998) Am. J. Orthop. , vol.27 , pp. 682-688
    • Gaul, J.S.1    Rosenberg, S.N.2
  • 11
    • 0023151376 scopus 로고
    • Unstable metacarpal and phalangeal fractures treatment with screws and plates
    • Hastings H II (1987) Unstable metacarpal and phalangeal fractures treatment with screws and plates. Clin Orthop 214:37-52
    • (1987) Clin. Orthop. , vol.214 , pp. 37-52
    • Hastings II, H.1
  • 12
    • 0027377455 scopus 로고
    • Dynamic external fixation for fractures of the proximal interphalangeal joint
    • Hastings H 2nd, Ernst JMJ (1993) Dynamic external fixation for fractures of the proximal interphalangeal joint. Hand Clin 9:659-674
    • (1993) Hand Clin. , vol.9 , pp. 659-674
    • Hastings II, H.1    Ernst, J.M.J.2
  • 13
    • 0035060290 scopus 로고    scopus 로고
    • Dynamic external fixation for pilon fractures of the interphalangeal joint
    • Hynes MC, Giddins GE (2001) Dynamic external fixation for pilon fractures of the interphalangeal joint. J Hand Surg Br 26:122-124
    • (2001) J. Hand Surg. Br. , vol.26 , pp. 122-124
    • Hynes, M.C.1    Giddins, G.E.2
  • 14
    • 0027458688 scopus 로고
    • Dynamic external finger fixator for fracture dislocation of the proximal interphalangeal joint
    • Inanami H, Ninomiya S, Okutsu I, Tarui T (1993) Dynamic external finger fixator for fracture dislocation of the proximal interphalangeal joint. J Hand Surg Am 18:160-164
    • (1993) J. Hand Surg. Am. , vol.18 , pp. 160-164
    • Inanami, H.1    Ninomiya, S.2    Okutsu, I.3    Tarui, T.4
  • 15
    • 0029920010 scopus 로고    scopus 로고
    • Hinged device for fractures involving the proximal interphalangeal joint
    • Krakauer JD, Stern PJ (1996) Hinged device for fractures involving the proximal interphalangeal joint. Clin Orthop 327:29-37
    • (1996) Clin. Orthop. , vol.327 , pp. 29-37
    • Krakauer, J.D.1    Stern, P.J.2
  • 16
    • 0029051847 scopus 로고
    • Dynamic digital traction for unstable comminuted intra-articular fracture dislocations of the proximal interphalangeal joint
    • Morgan JP, Gordon DA, Klug MS, Perry PE, Barre PS (1995) Dynamic digital traction for unstable comminuted intra-articular fracture dislocations of the proximal interphalangeal joint. J Hand Surg Am 20:565-573
    • (1995) J. Hand Surg. Am. , vol.20 , pp. 565-573
    • Morgan, J.P.1    Gordon, D.A.2    Klug, M.S.3    Perry, P.E.4    Barre, P.S.5
  • 17
    • 0035135607 scopus 로고    scopus 로고
    • Treatment of phalangeal fractures by tension band wiring
    • Safoury Y (2001) Treatment of phalangeal fractures by tension band wiring. J Hand Surg Br 26:50-52
    • (2001) J. Hand Surg. Br. , vol.26 , pp. 50-52
    • Safoury, Y.1
  • 18
    • 0022819690 scopus 로고
    • Dynamic traction and early passive movement for fractures of the proximal interphalangeal joint
    • Schenck RR (1986) Dynamic traction and early passive movement for fractures of the proximal interphalangeal joint. J Hand Surg Am 11:850-858
    • (1986) J. Hand Surg. Am. , vol.11 , pp. 850-858
    • Schenck, R.R.1
  • 20
    • 0027957723 scopus 로고
    • The pins and rubber traction system for treatment of comminuted intra-articular fractures and fracture-dislocations in the hand
    • Suzuki Y, Matsunaga T, Sato S, Yokoi T (1994) The pins and rubber traction system for treatment of comminuted intra-articular fractures and fracture-dislocations in the hand. J Hand Surg Br 19:98-107
    • (1994) J. Hand Surg. Br. , vol.19 , pp. 98-107
    • Suzuki, Y.1    Matsunaga, T.2    Sato, S.3    Yokoi, T.4
  • 21
    • 0037384059 scopus 로고    scopus 로고
    • Dynamic external fixator for pilon fractures of the proximal interphalangeal joint: A simple fixator for a complex fracture
    • Syed AA, Agarwal M, Boome R (2003) Dynamic external fixator for pilon fractures of the proximal interphalangeal joint: A simple fixator for a complex fracture. J Hand Surg Br 28:137-141
    • (2003) J. Hand Surg. Br. , vol.28 , pp. 137-141
    • Syed, A.A.1    Agarwal, M.2    Boome, R.3
  • 22
    • 0026639929 scopus 로고
    • Extension block pinning for proximal interphalangeal joint fracture dislocations: Preliminary report of a new technique
    • Viegas SF (1992) Extension block pinning for proximal interphalangeal joint fracture dislocations: Preliminary report of a new technique. J Hand Surg 17:896-901
    • (1992) J. Hand Surg. , vol.17 , pp. 896-901
    • Viegas, S.F.1
  • 23
    • 0030004668 scopus 로고    scopus 로고
    • Cerclage fixation for fracture dislocation of the proximal interphalangeal joint
    • Weiss APC (1996) Cerclage fixation for fracture dislocation of the proximal interphalangeal joint. Clin Orthop 327:21-28
    • (1996) Clin. Orthop. , vol.327 , pp. 21-28
    • Weiss, A.P.C.1
  • 24
    • 0028917527 scopus 로고
    • Intra-articular impaction fractures of the phalanges
    • Wolfe SW, Katz LD (1995) Intra-articular impaction fractures of the phalanges. J Hand Surg Am 20:327-333
    • (1995) J. Hand Surg. Am. , vol.20 , pp. 327-333
    • Wolfe, S.W.1    Katz, L.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.