메뉴 건너뛰기




Volumn 82, Issue 3, 2004, Pages 471-477

Development of two-point dynamic method for evaluating extraction columns

Author keywords

Axial diffusion model; Pulsed sieve plate extraction column; Two point dynamic method

Indexed keywords

DIFFUSION; EXTRACTION; MASS TRANSFER; MATHEMATICAL MODELS;

EID: 11244305569     PISSN: 00084034     EISSN: None     Source Type: Journal    
DOI: 10.1002/cjce.5450820307     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 24444437044 scopus 로고
    • Continuous-flow systems. Distribution of residence times
    • Danckwerts, P. V., "Continuous-flow systems. Distribution of Residence Times", Chem. Eng. Sci. 2, 1-4 (1953).
    • (1953) Chem. Eng. Sci. , vol.2 , pp. 1-4
    • Danckwerts, P.V.1
  • 3
    • 0022780413 scopus 로고
    • Liquid-liquid extraction column (rotating disc contactor)-model parameters from drop size distribution and solute concentration measurements
    • Korchinsky, W. J. and R. Al-Husseini, "Liquid-Liquid Extraction Column (Rotating Disc Contactor)-Model Parameters from Drop Size Distribution and Solute Concentration Measurements", J. Chem. Tech. Biotechnol. 36, 395-409 (1986).
    • (1986) J. Chem. Tech. Biotechnol. , vol.36 , pp. 395-409
    • Korchinsky, W.J.1    Al-Husseini, R.2
  • 5
    • 0039061017 scopus 로고
    • Diffusion-type method for the longitudinal mixing of fluids in flow
    • Levenspiel, O. and W. K. Smith, "Diffusion-type Method for the Longitudinal Mixing of Fluids in Flow", Chem. Eng. Sci. 6, 227-233 (1957).
    • (1957) Chem. Eng. Sci. , vol.6 , pp. 227-233
    • Levenspiel, O.1    Smith, W.K.2
  • 9
    • 0019539731 scopus 로고
    • An efficient general method for computation of countercurrent separation process with axial dispersion
    • Ricker, N. L., Nakashio Fumiyuki and C. J. King, "An Efficient General Method for Computation of Countercurrent Separation Process with Axial Dispersion", AICHE J. 27, 277-284 (1981).
    • (1981) AICHE J. , vol.27 , pp. 277-284
    • Ricker, N.L.1    Fumiyuki, N.2    King, C.J.3
  • 10
    • 0020812069 scopus 로고
    • Evaluation of mass transfer and backmixing parameters in extraction column from measured solute concentrations
    • Rod, V., Fei Wei-Yang and C. Hanson, "Evaluation of Mass Transfer and Backmixing Parameters in Extraction Column from Measured Solute Concentrations", Chem. Eng. Res. Des. 61, 290-296 (1983).
    • (1983) Chem. Eng. Res. Des. , vol.61 , pp. 290-296
    • Rod, V.1    Wei-Yang, F.2    Hanson, C.3
  • 11
    • 11244295103 scopus 로고
    • Longitudinal mixing studies in a pulsed extraction column
    • Sehmel, G. A. and A. L Babb, "Longitudinal Mixing Studies in a Pulsed Extraction Column", Ind. Eng. Chem. Process Des. Dev. 3, 210-217 (1964).
    • (1964) Ind. Eng. Chem. Process Des. Dev. , vol.3 , pp. 210-217
    • Sehmel, G.A.1    Babb, A.L.2
  • 12
    • 2442531349 scopus 로고
    • Mass transfer studies in a pulsed extraction column. Longitudinal concentration profiles
    • Smoot, L. D. and A. L. Babb, "Mass Transfer Studies in a Pulsed Extraction Column. Longitudinal Concentration Profiles", Ind. Eng. Chem. Fund. 1, 93-103 (1962).
    • (1962) Ind. Eng. Chem. Fund. , vol.1 , pp. 93-103
    • Smoot, L.D.1    Babb, A.L.2
  • 13
    • 0017957950 scopus 로고
    • Mass transfer between two liquid phase in a spray column at the unsteady state
    • Steiner, L., Horvath, M. and S. Hartland, "Mass Transfer between Two Liquid Phase in a Spray Column at the Unsteady State", Ind. Eng. Chem. Process Des. Dev. 17, 175-182 (1978).
    • (1978) Ind. Eng. Chem. Process Des. Dev. , vol.17 , pp. 175-182
    • Steiner, L.1    Horvath, M.2    Hartland, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.