메뉴 건너뛰기




Volumn 44, Issue 10, 2004, Pages 998-1003

Proximal protection systems using carotid artery stent;Proximale protektions-systeme beim karotisstent

Author keywords

Carotid artery angioplasty; Carotid artery stenosis; Carotid artery stenting; Proximal protection device

Indexed keywords

ARTICLE; BALLOON OCCLUSION; BRAIN PROTECTION; CAROTID ARTERIOGRAPHY; CAROTID ARTERY; CAROTID ARTERY FLOW; CAROTID ARTERY STENT; FILTRATION; HUMAN; STENT; BRAIN EMBOLISM; CAROTID ARTERY OBSTRUCTION; COMPARATIVE STUDY; EQUIPMENT DESIGN; INSTRUMENTATION; INTERNAL CAROTID ARTERY; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; RADIOGRAPHY; REVIEW;

EID: 11244264345     PISSN: 0033832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00117-004-1112-y     Document Type: Article
Times cited : (4)

References (43)
  • 1
    • 0029054874 scopus 로고
    • The significance of microemboli detection by means of transcranial Doppler ultrasonography monitoring in carotid endarterectomy
    • Ackerstaff RGA, Jansen C, Moll FL, Vermeulen FEE, Manerlijnck RPHM, Mauser HW (1995) The significance of microemboli detection by means of transcranial Doppler ultrasonography monitoring in carotid endarterectomy. J Vasc Surg 21:963-969
    • (1995) J Vasc Surg , vol.21 , pp. 963-969
    • Ackerstaff, R.G.A.1    Jansen, C.2    Moll, F.L.3    Vermeulen, F.E.E.4    Manerlijnck, R.P.H.M.5    Mauser, H.W.6
  • 2
    • 0035940384 scopus 로고    scopus 로고
    • Effect of the distal-balloon protection system on microembolization during carotid stenting
    • Al-Mubarak N, Roubin GS, Vitek JJ, Iyer SS, New G, Leon MB (2001) Effect of the distal-balloon protection system on microembolization during carotid stenting. Circulation 104:1999-2002
    • (2001) Circulation , vol.104 , pp. 1999-2002
    • Al-Mubarak, N.1    Roubin, G.S.2    Vitek, J.J.3    Iyer, S.S.4    New, G.5    Leon, M.B.6
  • 3
    • 0031761429 scopus 로고    scopus 로고
    • Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty
    • Bladin CF, Bingham L, Grigg L, Yapanis AG, Gerraty R, Davis SM (1998) Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty. Stroke 29:2367-2370
    • (1998) Stroke , vol.29 , pp. 2367-2370
    • Bladin, C.F.1    Bingham, L.2    Grigg, L.3    Yapanis, A.G.4    Gerraty, R.5    Davis, S.M.6
  • 4
    • 0023001691 scopus 로고
    • Rentinal microembolism during cardiopulmonary bypass demonstrated by fluorescein angiography
    • Blauth C, Arnold J, Kohner EM, Taylor KM (1986) Rentinal microembolism during cardiopulmonary bypass demonstrated by fluorescein angiography. Lancet 2:837-839
    • (1986) Lancet , vol.2 , pp. 837-839
    • Blauth, C.1    Arnold, J.2    Kohner, E.M.3    Taylor, K.M.4
  • 5
    • 18444403437 scopus 로고    scopus 로고
    • Use of the Parodi anti-embolism system in carotid stenting: Italian Trial Results
    • Carlo A, Adami, Scuro A et al. (2002) Use of the Parodi anti-embolism system in carotid stenting: Italian Trial Results. J Endovasc Ther 9 (2):147-154
    • (2002) J Endovasc Ther , vol.9 , Issue.2 , pp. 147-154
    • Carlo, A.1    Adami2    Scuro, A.3
  • 6
    • 0035795969 scopus 로고    scopus 로고
    • Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): A randomized trial
    • CAVATAS Investigators (2001) Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): a randomized trial. Lancet 357:1729-1737
    • (2001) Lancet , vol.357 , pp. 1729-1737
  • 7
    • 0034019453 scopus 로고    scopus 로고
    • Embolic risk of the different stages of carotid bifurcation balloon angioplasty: An experimental study
    • Coggia M, Goeau-Brissonniere O, Duval JL, Leschi JP, Letort M, Nagel MD (2000) Embolic risk of the different stages of carotid bifurcation balloon angioplasty: an experimental study. J Vasc Surg 31:550-557
    • (2000) J Vasc Surg , vol.31 , pp. 550-557
    • Coggia, M.1    Goeau-Brissonniere, O.2    Duval, J.L.3    Leschi, J.P.4    Letort, M.5    Nagel, M.D.6
  • 8
    • 0031453560 scopus 로고    scopus 로고
    • Comparison of hemodynamic cerebral ischemia and microembolic signals detected during carotid endarterectomy and carotid angioplasty
    • Crawley F, Clifton A, Buckenham T, Loosemore T, Taylor RS, Brown MM (1997) Comparison of hemodynamic cerebral ischemia and microembolic signals detected during carotid endarterectomy and carotid angioplasty. Stroke 28:2460-2464
    • (1997) Stroke , vol.28 , pp. 2460-2464
    • Crawley, F.1    Clifton, A.2    Buckenham, T.3    Loosemore, T.4    Taylor, R.S.5    Brown, M.M.6
  • 9
    • 0042905775 scopus 로고    scopus 로고
    • Protected carotid stenting: Clinical advantages and complications of embolic protection devices in 442 consecutive patients
    • Cremonesi A, Manetti R, Castriota F, Setacci F, Setacci C (2003) Protected carotid stenting: clinical advantages and complications of embolic protection devices in 442 consecutive patients. Stroke 34:1936-1943
    • (2003) Stroke , vol.34 , pp. 1936-1943
    • Cremonesi, A.1    Manetti, R.2    Castriota, F.3    Setacci, F.4    Setacci, C.5
  • 10
    • 0030936765 scopus 로고    scopus 로고
    • Transcranial Doppler sonographic monitoring during percutaneous transluminal angioplasty of the internal carotid artery
    • Eckert B, Thie A, Valdeza J, Zanella F, Zeumer H (1997) Transcranial Doppler sonographic monitoring during percutaneous transluminal angioplasty of the internal carotid artery. Neuroradiology 39:229-234
    • (1997) Neuroradiology , vol.39 , pp. 229-234
    • Eckert, B.1    Thie, A.2    Valdeza, J.3    Zanella, F.4    Zeumer, H.5
  • 11
    • 0042122418 scopus 로고    scopus 로고
    • Editorial comment - Carotid artery stenting with or without protection devices? Strong opinions, poor evidence!
    • Eckert B, Zeumer H (2003) Editorial comment - carotid artery stenting with or without protection devices? Strong opinions, poor evidence! Stroke 34 (8):1941-1943
    • (2003) Stroke , vol.34 , Issue.8 , pp. 1941-1943
    • Eckert, B.1    Zeumer, H.2
  • 12
    • 0032499446 scopus 로고    scopus 로고
    • Randomized trial of endarterectomy for recently symptomatic carotid stenosis: Final results of the MRC European Carotid Surgery Trial (ECST)
    • European Carotid Surgery Trialists' Collaborative Group (1998) Randomized trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST). Lancet 351:1379-1387
    • (1998) Lancet , vol.351 , pp. 1379-1387
  • 13
    • 0028938324 scopus 로고
    • Endarterectomy for asymptomatic carotid artery stenosis
    • Executive Committee for the Asymptomatic Carotid Atherosclerosis Study (1995) Endarterectomy for asymptomatic carotid artery stenosis. JAMA 273:1421-1428
    • (1995) JAMA , vol.273 , pp. 1421-1428
  • 14
    • 0032853007 scopus 로고    scopus 로고
    • The North American Symptomatic Carotid Endarterectomy Trial: Surgical results in 1415 patients
    • Ferguson GG, Eliasziw M, Barr HW et al. (1999) The North American Symptomatic Carotid Endarterectomy Trial: surgical results in 1415 patients. Stroke 30:1751-1758
    • (1999) Stroke , vol.30 , pp. 1751-1758
    • Ferguson, G.G.1    Eliasziw, M.2    Barr, H.W.3
  • 15
    • 0028049036 scopus 로고
    • Clinical relevance of intraoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: A prospective study of 100 patients
    • Gaunt MJ, Martin PJ, Smith JL, Rimmer T, Cherryman G, Ratliff DA, Bell PRF, Naylor AR (1994) Clinical relevance of intraoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: a prospective study of 100 patients. Br J Surg 81:1435-1439
    • (1994) Br J Surg , vol.81 , pp. 1435-1439
    • Gaunt, M.J.1    Martin, P.J.2    Smith, J.L.3    Rimmer, T.4    Cherryman, G.5    Ratliff, D.A.6    Bell, P.R.F.7    Naylor, A.R.8
  • 16
    • 0017192639 scopus 로고
    • Changes in mental functions after open-heart operations
    • Gruvstad M, Hane M (1975) Changes in mental functions after open-heart operations. Scand J Thorac Cardiovasc Surg 10:215-220
    • (1975) Scand J Thorac Cardiovasc Surg , vol.10 , pp. 215-220
    • Gruvstad, M.1    Hane, M.2
  • 19
    • 0030047701 scopus 로고    scopus 로고
    • Results of balloon angioplasty in the carotid arteries
    • Kachel R (1996) Results of balloon angioplasty in the carotid arteries. J Endovasc Surg 3:22-30
    • (1996) J Endovasc Surg , vol.3 , pp. 22-30
    • Kachel, R.1
  • 20
    • 0037337064 scopus 로고    scopus 로고
    • Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: A systematic review of the literature
    • Kastrup A, Groschel K, Krapf H, Brehm BR, Dichgans J, Schulz JB (2003) Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: a systematic review of the literature. Stroke 34:813-881
    • (2003) Stroke , vol.34 , pp. 813-881
    • Kastrup, A.1    Groschel, K.2    Krapf, H.3    Brehm, B.R.4    Dichgans, J.5    Schulz, J.B.6
  • 22
    • 0027406243 scopus 로고
    • Microscopic air embolism during cerebral angiography and strategies for its avoidance
    • Markus H, Loh A, Israel D, Buckenham T, Clifton A, Brown MM (1993) Microscopic air embolism during cerebral angiography and strategies for its avoidance. Lancet 541:784-787
    • (1993) Lancet , vol.541 , pp. 784-787
    • Markus, H.1    Loh, A.2    Israel, D.3    Buckenham, T.4    Clifton, A.5    Brown, M.M.6
  • 23
    • 0027999991 scopus 로고
    • Carotid angioplasty-detection of embolic signals during and after the procedure
    • Markus HS, Clifton A, Buckenham T, Brown MT (1994) Carotid angioplasty-detection of embolic signals during and after the procedure. Stroke 25:2403-2406
    • (1994) Stroke , vol.25 , pp. 2403-2406
    • Markus, H.S.1    Clifton, A.2    Buckenham, T.3    Brown, M.T.4
  • 25
    • 0031837641 scopus 로고    scopus 로고
    • Cerebral haemodynamics and embolization during carotid angioplasty in high-risk patients
    • McCleary AJ, Nelson M, Dearden NM, Calvey TAJ, Gough MJ (1998) Cerebral haemodynamics and embolization during carotid angioplasty in high-risk patients. Br J Surg 85:771-774
    • (1998) Br J Surg , vol.85 , pp. 771-774
    • McCleary, A.J.1    Nelson, M.2    Dearden, N.M.3    Calvey, T.A.J.4    Gough, M.J.5
  • 26
    • 0032469037 scopus 로고    scopus 로고
    • Carotid rupture and intraplaque hemorrhage: Immunophenotype and role of cells involved
    • Milei J, Parodi JC, Alonso GF, Barone A, Grana D, Matturri L (1998) Carotid rupture and intraplaque hemorrhage: immunophenotype and role of cells involved. Am Heart J 136:1096-1105
    • (1998) Am Heart J , vol.136 , pp. 1096-1105
    • Milei, J.1    Parodi, J.C.2    Alonso, G.F.3    Barone, A.4    Grana, D.5    Matturri, L.6
  • 27
    • 0141561589 scopus 로고    scopus 로고
    • Zerebrale Protektionssysteme für die Behandlung der Karotisstenose - Eine Standortbestimmung
    • Müller-Hülsbeck S (2002) Zerebrale Protektionssysteme für die Behandlung der Karotisstenose - Eine Standortbestimmung. Fortschr Rontgenstr 74:945-954
    • (2002) Fortschr Rontgenstr , vol.74 , pp. 945-954
    • Müller-Hülsbeck, S.1
  • 28
    • 0034093906 scopus 로고    scopus 로고
    • Carotid stenting with and without protection devices: Should protection be used in all patients?
    • Ohki T, Veith FJ (2000) Carotid stenting with and without protection devices: should protection be used in all patients? Semin Vasc Surg 13:144-152
    • (2000) Semin Vasc Surg , vol.13 , pp. 144-152
    • Ohki, T.1    Veith, F.J.2
  • 30
    • 0032763179 scopus 로고    scopus 로고
    • Efficacy of a filter in the prevention of embolic events during carotid angioplasty and stenting: An ex-vitro study
    • Ohki T, Roubin GS, Veith FJ, Iyer SS, Brady E (1999) Efficacy of a filter in the prevention of embolic events during carotid angioplasty and stenting: an ex-vitro study. J Vasc Surg 30:1034-1044
    • (1999) J Vasc Surg , vol.30 , pp. 1034-1044
    • Ohki, T.1    Roubin, G.S.2    Veith, F.J.3    Iyer, S.S.4    Brady, E.5
  • 33
    • 0031894263 scopus 로고    scopus 로고
    • Consensus on microembolus detection by TCD: International Consensus Group on Microembolus Detection
    • Ringelstein EB, Droste DW, Babikian VL et al. (1998) Consensus on microembolus detection by TCD: International Consensus Group on Microembolus Detection. Stroke 29:725-729
    • (1998) Stroke , vol.29 , pp. 725-729
    • Ringelstein, E.B.1    Droste, D.W.2    Babikian, V.L.3
  • 34
    • 0035970028 scopus 로고    scopus 로고
    • Immediate and late clinical outcomes of carotid artery stenting in patients with symptomatic and asymptomatic carotid artery stenosis: A 5-year prospective analysis
    • Roubin GS, New G, Iyer SS et al. (2001) Immediate and late clinical outcomes of carotid artery stenting in patients with symptomatic and asymptomatic carotid artery stenosis: a 5-year prospective analysis. Circulation 103:532-537
    • (2001) Circulation , vol.103 , pp. 532-537
    • Roubin, G.S.1    New, G.2    Iyer, S.S.3
  • 35
    • 0022580628 scopus 로고
    • Early intellectual dysfunction following coronary artery bypass surgery
    • Shaw PJ, Bates D, Cartlidge NEF et al. (1986) Early intellectual dysfunction following coronary artery bypass surgery. QJ Med 58:59-68
    • (1986) QJ Med , vol.58 , pp. 59-68
    • Shaw, P.J.1    Bates, D.2    Cartlidge, N.E.F.3
  • 36
    • 0030932286 scopus 로고    scopus 로고
    • Transcranial Doppler monitoring and causes of stroke from carotid endarterectomy
    • Spencer MP (1997) Transcranial Doppler monitoring and causes of stroke from carotid endarterectomy. Stroke 28:685-691
    • (1997) Stroke , vol.28 , pp. 685-691
    • Spencer, M.P.1
  • 37
    • 0025317321 scopus 로고
    • Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography
    • Spencer MP, Thomas GI, Nicholls SC, Sauvage LR (1990) Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography. Stroke 21:415-423
    • (1990) Stroke , vol.21 , pp. 415-423
    • Spencer, M.P.1    Thomas, G.I.2    Nicholls, S.C.3    Sauvage, L.R.4
  • 38
    • 0034852489 scopus 로고    scopus 로고
    • Cerebral protection systems for distal emboli during carotid artery interventions
    • Tan WA, Bates MC, Wholey MH (2001) Cerebral protection systems for distal emboli during carotid artery interventions. J Interv Cardiol 14:465-474
    • (2001) J Interv Cardiol , vol.14 , pp. 465-474
    • Tan, W.A.1    Bates, M.C.2    Wholey, M.H.3
  • 39
    • 0023217999 scopus 로고
    • Percutaneous angioplasty of atherosclerotic and postsurgical stenosis of carotid arteries
    • Théron J, Raymond J, Casasco A, Courtheoux F (1987) Percutaneous angioplasty of atherosclerotic and postsurgical stenosis of carotid arteries. Am J Neuroradiol 8:495-500
    • (1987) Am J Neuroradiol , vol.8 , pp. 495-500
    • Théron, J.1    Raymond, J.2    Casasco, A.3    Courtheoux, F.4
  • 40
    • 0033800877 scopus 로고    scopus 로고
    • Karotisstenose: Technik der PTA und Stent-Implantation
    • Thurnher S (2000) Karotisstenose: Technik der PTA und Stent-Implantation. Radiologe 40:798-804
    • (2000) Radiologe , vol.40 , pp. 798-804
    • Thurnher, S.1
  • 41
    • 0035111668 scopus 로고    scopus 로고
    • Current status of carotid bifurcation angioplasty and stenting based on a consensus of opinion leaders
    • Veith FJ, Amor M, Ohki T et al. (2001) Current status of carotid bifurcation angioplasty and stenting based on a consensus of opinion leaders. J Vasc Surg 33:111-116
    • (2001) J Vasc Surg , vol.33 , pp. 111-116
    • Veith, F.J.1    Amor, M.2    Ohki, T.3
  • 43
    • 18344406356 scopus 로고    scopus 로고
    • Global experience in cervical carotid artery stent placement
    • Wholey MH, Wholey M, Mathias K et al. (2000) Global experience in cervical carotid artery stent placement. Cathet Cardiovasc Interv 50:160-167
    • (2000) Cathet Cardiovasc Interv , vol.50 , pp. 160-167
    • Wholey, M.H.1    Wholey, M.2    Mathias, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.