메뉴 건너뛰기




Volumn 9, Issue 6, 2004, Pages 551-554

Ectopic bone formation around the poly-L-lactide screw head in rotational acetabular osteotomy for hip dysplasia

Author keywords

Acetabular dysplasia; Ectopic bone formation; Poly L lactide; Rotational acetabular osteotomy

Indexed keywords

POLYLACTIC ACID;

EID: 11244255025     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00776-004-0838-8     Document Type: Article
Times cited : (6)

References (15)
  • 1
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement
    • Am
    • Brooker AF, Bowerman JW, Robinson RA, et al. Ectopic ossification following total hip replacement. J Bone Joint Surg [Am] 1973;55:1629-32.
    • (1973) J Bone Joint Surg , vol.55 , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3
  • 2
    • 0028316813 scopus 로고
    • Fixation with bioabsorbable screws for the treatment of fractures of the ankle
    • Am
    • Bucholz RW, Henry S, Henley MB. Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg [Am] 1994;76A:319-24.
    • (1994) J Bone Joint Surg , vol.76 A , pp. 319-324
    • Bucholz, R.W.1    Henry, S.2    Henley, M.B.3
  • 3
    • 0025971712 scopus 로고
    • Current concepts review. Absorbable implants for the fixation of fractures
    • Am
    • Böstman OM. Current concepts review. Absorbable implants for the fixation of fractures. J Bone Joint Surg [Am] 1991;73:148-53.
    • (1991) J Bone Joint Surg , vol.73 , pp. 148-153
    • Böstman, O.M.1
  • 4
    • 0347623805 scopus 로고    scopus 로고
    • Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws. A three- To nine-year followup study
    • Br
    • Böstman OM. Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws. A three- to nine-year followup study. J Bone Joint Surg [Br] 1998;80:333-8.
    • (1998) J Bone Joint Surg , vol.80 , pp. 333-338
    • Böstman, O.M.1
  • 5
    • 0026513175 scopus 로고
    • Severe aseptic synovitis of the knee after biodegradable internal fixation
    • Freden T, Rydholm U. Severe aseptic synovitis of the knee after biodegradable internal fixation. Acta Orthop Scand 1992;63:94-7.
    • (1992) Acta Orthop Scand , vol.63 , pp. 94-97
    • Freden, T.1    Rydholm, U.2
  • 6
    • 0036518004 scopus 로고    scopus 로고
    • Eccentric rotational acetabular osteotomy for acetabular dysplasia: Follow-up of one hundred and thirty-two hips for five to ten years
    • Am
    • Hasegawa Y, Iwase T, Kitamura S, et al. Eccentric rotational acetabular osteotomy for acetabular dysplasia: follow-up of one hundred and thirty-two hips for five to ten years. J Bone Joint Surg [Am] 2002;84:404-10.
    • (2002) J Bone Joint Surg , vol.84 , pp. 404-410
    • Hasegawa, Y.1    Iwase, T.2    Kitamura, S.3
  • 7
    • 0036436263 scopus 로고    scopus 로고
    • The long term behavior of poly-L-lactide screws in a minipig fracture model: Preliminary report
    • Hasegawa Y, Sakano S, Iwase T, et al. The long term behavior of poly-L-lactide screws in a minipig fracture model: preliminary report. J Biomed Mater Res (Appl Biomater) 2003;63:679-85.
    • (2003) J Biomed Mater Res (Appl Biomater) , vol.63 , pp. 679-685
    • Hasegawa, Y.1    Sakano, S.2    Iwase, T.3
  • 8
    • 85030818291 scopus 로고    scopus 로고
    • Post-operative MRI findings of rotational acetabular osteotomy using poly-L-lactide screws
    • in Japanese
    • Higuchi F, Suzuki R, Yamanaka K, et al. Post-operative MRI findings of rotational acetabular osteotomy using poly-L-lactide screws. Hip Joint 2000;26:433-78 (in Japanese).
    • (2000) Hip Joint , vol.26 , pp. 433-478
    • Higuchi, F.1    Suzuki, R.2    Yamanaka, K.3
  • 9
    • 0020702162 scopus 로고
    • Preliminary report on the osteogenic potential of a biodegradable copolymer of polylactide (PLA) and polyglycolide (PGA)
    • Hollinger JO. Preliminary report on the osteogenic potential of a biodegradable copolymer of polylactide (PLA) and polyglycolide (PGA). J Bone Miner Res 1983;17:71-82.
    • (1983) J Bone Miner Res , vol.17 , pp. 71-82
    • Hollinger, J.O.1
  • 10
    • 0026124778 scopus 로고
    • Biodegradable screw fixation of rabbit tibia proximal osteotomy
    • Matsusue Y, Yamamuro T, Yoshii S, et al. Biodegradable screw fixation of rabbit tibia proximal osteotomy. J Appl Biomat 1991;2:1-12.
    • (1991) J Appl Biomat , vol.2 , pp. 1-12
    • Matsusue, Y.1    Yamamuro, T.2    Yoshii, S.3
  • 11
    • 0029120601 scopus 로고
    • Tissue reaction of bioabsorbable ultra high strength poly (L-lactide) rod. A long-term study in rabbits
    • Matsusue Y, Hanafusa S, Yamamuro T, et al. Tissue reaction of bioabsorbable ultra high strength poly (L-lactide) rod. A long-term study in rabbits. Clin Orthop 1995;317:246-53.
    • (1995) Clin Orthop , vol.317 , pp. 246-253
    • Matsusue, Y.1    Hanafusa, S.2    Yamamuro, T.3
  • 12
    • 0032881741 scopus 로고    scopus 로고
    • Rotational acetabular osteotomy using biodegradable internal fixation
    • Nakamura S, Takatori Y, Morimoto S, et al. Rotational acetabular osteotomy using biodegradable internal fixation. Int Orthop 1999;23:148-9.
    • (1999) Int Orthop , vol.23 , pp. 148-149
    • Nakamura, S.1    Takatori, Y.2    Morimoto, S.3
  • 13
    • 0033067026 scopus 로고    scopus 로고
    • SR-PLLA and SR-PGA miniscrews: Biodegradation and tissue reactions in the calvarium and dura mater
    • Peltoniemi HH, Hallikainen D, Toivonen T, et al. SR-PLLA and SR-PGA miniscrews: biodegradation and tissue reactions in the calvarium and dura mater. J Craniomaxillofac Surg 1999;27:42-50.
    • (1999) J Craniomaxillofac Surg , vol.27 , pp. 42-50
    • Peltoniemi, H.H.1    Hallikainen, D.2    Toivonen, T.3
  • 14
    • 0029891715 scopus 로고    scopus 로고
    • Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation. Experimental study in sheep
    • Br
    • Weiler A, Helling H-J, Kirch U, et al. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation. Experimental study in sheep. J Bone Joint Surg [Br] 1996;78:369-76.
    • (1996) J Bone Joint Surg , vol.78 , pp. 369-376
    • Weiler, A.1    Helling, H.-J.2    Kirch, U.3
  • 15
    • 0028593351 scopus 로고
    • Bioabsorbable osteosynthetic implants of ultra high strength poly-L-lactide: A clinical study
    • Yamamuro T, Matsusue Y, Uchida A, et al. Bioabsorbable osteosynthetic implants of ultra high strength poly-L-lactide: a clinical study. Int Orthop 1994;18:332-40.
    • (1994) Int Orthop , vol.18 , pp. 332-340
    • Yamamuro, T.1    Matsusue, Y.2    Uchida, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.