메뉴 건너뛰기




Volumn 52, Issue 1, 2005, Pages 127-131

Navigator echo motion artifact suppression in synthetic aperture ultrasound imaging

Author keywords

Information theoretic image enhancement; Motion artifact; Navigator echo; Synthetic aperture

Indexed keywords

COMPUTER SIMULATION; COSTS; MEDICAL IMAGING;

EID: 11244250597     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2004.836501     Document Type: Article
Times cited : (3)

References (11)
  • 1
    • 84942213276 scopus 로고
    • Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities - Part I: Basic principles
    • July
    • G. E. Trahey and L. F. Nock, "Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities - part I: basic principles," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, pp. 489-495, July 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.39 , pp. 489-495
    • Trahey, G.E.1    Nock, L.F.2
  • 2
    • 0025575419 scopus 로고
    • Synthetic aperture imaging in medical ultrasound with correction for motion artifacts
    • L. F. Nock and G. E. Trahey, "Synthetic aperture imaging in medical ultrasound with correction for motion artifacts," in Proc. 1990 IEEE Ultrason. Symp., 1990, pp. 1597-1601.
    • (1990) Proc. 1990 IEEE Ultrason. Symp. , pp. 1597-1601
    • Nock, L.F.1    Trahey, G.E.2
  • 3
    • 0033353649 scopus 로고    scopus 로고
    • Correlation processing for correction of phase distortions in subaperture imaging
    • Nov.
    • B. Tavli and M. Karaman, "Correlation processing for correction of phase distortions in subaperture imaging," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 46, pp. 1477-1488, Nov. 1999.
    • (1999) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.46 , pp. 1477-1488
    • Tavli, B.1    Karaman, M.2
  • 4
    • 0032180341 scopus 로고    scopus 로고
    • Bidirectional pixel based focusing in conventional B-mode ultrasound imaging
    • M.-H. Bae and M.-K. Jeong, "Bidirectional pixel based focusing in conventional B-mode ultrasound imaging," Electron. Lett., vol. 34, no. 22, pp. 2105-2107, 1998.
    • (1998) Electron. Lett. , vol.34 , Issue.22 , pp. 2105-2107
    • Bae, M.-H.1    Jeong, M.-K.2
  • 5
    • 0034579682 scopus 로고    scopus 로고
    • Effects and limitations of motion compensation in synthetic aperture techniques
    • Oct.
    • J.-S. Jeong, J.-S. Hwang, M.-H. Bae, and T.-K. Song, "Effects and limitations of motion compensation in synthetic aperture techniques," in Proc. 2000 IEEE Ulttrasonics Symp., vol. 2, Oct. 2000, pp. 1759-1762.
    • (2000) Proc. 2000 IEEE Ulttrasonics Symp. , vol.2 , pp. 1759-1762
    • Jeong, J.-S.1    Hwang, J.-S.2    Bae, M.-H.3    Song, T.-K.4
  • 6
    • 0024111013 scopus 로고
    • Phase-aberration correction using signals from point reflectors and diffuse scatterers: Basic principles
    • S. W. Flax and M. O'Donnell, "Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 35, no. 6, pp. 758-767, 1988.
    • (1988) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.35 , Issue.6 , pp. 758-767
    • Flax, S.W.1    O'Donnell, M.2
  • 7
    • 0029884563 scopus 로고    scopus 로고
    • Algorithms for extracting motion information from navigator echos
    • Y. Wang, R. C. Grimm, J. P. Felmlee, S. J. Riederer, and R. L. Ehman, "Algorithms for extracting motion information from navigator echos," Magn. Reson. Med., vol. 36, pp. 117-123, 1996.
    • (1996) Magn. Reson. Med. , vol.36 , pp. 117-123
    • Wang, Y.1    Grimm, R.C.2    Felmlee, J.P.3    Riederer, S.J.4    Ehman, R.L.5
  • 8
    • 0031283439 scopus 로고    scopus 로고
    • Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
    • Dec.
    • D. Atkinson, D. L. G. Hill, P. N. R. Stoyle, P. E. Summers, and S. F. Keevil, "Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion, " IEEE Trans. Med. Imag., vol. 16, pp. 903-910, Dec. 1997.
    • (1997) IEEE Trans. Med. Imag. , vol.16 , pp. 903-910
    • Atkinson, D.1    Hill, D.L.G.2    Stoyle, P.N.R.3    Summers, P.E.4    Keevil, S.F.5
  • 9
    • 0024669887 scopus 로고
    • Phase aberration correction in medical ultrasound using speckle brightness as a quality factor
    • L. Nock and G. E. Trahey, "Phase aberration correction in medical ultrasound using speckle brightness as a quality factor," J. Acoust. Soc. Amer., vol. 85, no. 5, pp. 1819-1833, 1989.
    • (1989) J. Acoust. Soc. Amer. , vol.85 , Issue.5 , pp. 1819-1833
    • Nock, L.1    Trahey, G.E.2
  • 10
    • 24044478820 scopus 로고    scopus 로고
    • Field: A program for simulating ultrasound systems
    • Part 1: Proc. 10th Nordic-Baltic Conf. Biomed. Eng.
    • J. A. Jensen, "Field: a program for simulating ultrasound systems," Med. Biol. Eng. Comp., Suppl. 1, Part 1: Proc. 10th Nordic-Baltic Conf. Biomed. Eng., vol. 4, pp. 351-353, 1996.
    • (1996) Med. Biol. Eng. Comp. , vol.4 , Issue.SUPPL. 1 , pp. 351-353
    • Jensen, J.A.1
  • 11
    • 0029124063 scopus 로고
    • Methods for estimation of subsample time delays of digitized echo signals
    • I. Cespedes, Y. Huang, J. Ophir, and S. Spratt, "Methods for estimation of subsample time delays of digitized echo signals," Ultrason. Imag., vol. 17, pp. 142-171, 1995.
    • (1995) Ultrason. Imag. , vol.17 , pp. 142-171
    • Cespedes, I.1    Huang, Y.2    Ophir, J.3    Spratt, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.