메뉴 건너뛰기




Volumn 21, Issue 3, 2004, Pages 225-233

Noninvasive coronary flow velocity reserve measurement in the posterior descending coronary artery for detecting coronary stenosis in the right coronary artery using contrast-enhanced transthoracic doppler echocardiography

Author keywords

Coronary flow reserve; Coronary stenosis; Noninvasive; Right coronary artery; Transthoracic Doppler echocardiography

Indexed keywords

ADENOSINE TRIPHOSPHATE;

EID: 11144357390     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.0742-2822.2004.03028.x     Document Type: Article
Times cited : (25)

References (30)
  • 1
    • 0015966216 scopus 로고
    • Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve
    • Gould KL, Lipscomb K, Hamilton GW: Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol 1974;33:87-94.
    • (1974) Am J Cardiol , vol.33 , pp. 87-94
    • Gould, K.L.1    Lipscomb, K.2    Hamilton, G.W.3
  • 2
    • 0019465581 scopus 로고
    • Measurements of coronary velocity and reactive hyperemia in the coronary circulation of humans
    • Marcus M, Wright C, Doty D, et al: Measurements of coronary velocity and reactive hyperemia in the coronary circulation of humans. Circ Res 1981;49:877-891.
    • (1981) Circ Res , vol.49 , pp. 877-891
    • Marcus, M.1    Wright, C.2    Doty, D.3
  • 3
    • 0021137038 scopus 로고
    • Maximal coronary flow and the concept of coronary vascular reserve
    • Hoffman JI: Maximal coronary flow and the concept of coronary vascular reserve. Circulation 1984;70:153-159.
    • (1984) Circulation , vol.70 , pp. 153-159
    • Hoffman, J.I.1
  • 4
    • 0021844959 scopus 로고
    • Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man
    • Wilson RF, Laughlin DE, Ackell PH, et al: Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man. Circulation 1985;72:82-92.
    • (1985) Circulation , vol.72 , pp. 82-92
    • Wilson, R.F.1    Laughlin, D.E.2    Ackell, P.H.3
  • 5
    • 0023472538 scopus 로고
    • Measurements of coronary flow reserve: Denning pathophysiology versus making decisions about patient care
    • Klocke FJ: Measurements of coronary flow reserve: Denning pathophysiology versus making decisions about patient care. Circulation 1987;76:1183-1189.
    • (1987) Circulation , vol.76 , pp. 1183-1189
    • Klocke, F.J.1
  • 6
    • 0025875668 scopus 로고
    • Comparison of coronary vasodilation with intravenous dipyridamole and adenosine
    • Rossen JD, Quillen JE, Lopez AG, et al: Comparison of coronary vasodilation with intravenous dipyridamole and adenosine. J Am Coll Cardiol 1991;18:485-491.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 485-491
    • Rossen, J.D.1    Quillen, J.E.2    Lopez, A.G.3
  • 7
    • 0025785630 scopus 로고
    • Intravenous adenosine: Continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease
    • Kern MJ, Deligonul U, Tatineni S, et al: Intravenous adenosine: Continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease. J Am Coll Cardiol 1991;18:718-729.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 718-729
    • Kern, M.J.1    Deligonul, U.2    Tatineni, S.3
  • 8
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl PD, Payne HM, et al: Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 1992;85:1899-1911.
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3
  • 9
    • 0028235971 scopus 로고
    • Relation between myocardial blood flow and the severity of coronary-artery stenosis
    • Uren NG, Melin JA, De Bruyne B, et al: Relation between myocardial blood flow and the severity of coronary-artery stenosis. N Engl J Med 1994;330:1782-1788.
    • (1994) N Engl J Med , vol.330 , pp. 1782-1788
    • Uren, N.G.1    Melin, J.A.2    De Bruyne, B.3
  • 10
    • 0023253262 scopus 로고
    • Noninvasive measurement of coronary artery blood flow using combined two-dimensional and Doppler echocardiography
    • Fusejima K. Noninvasive measurement of coronary artery blood flow using combined two-dimensional and Doppler echocardiography. J Am Coll Cardiol 1987;10:1024-1031.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 1024-1031
    • Fusejima, K.1
  • 11
    • 0025093468 scopus 로고
    • Transthoracic two-dimensional high frequency (7.5 MHz) ultrasonic visualization of the distal left anterior descending coronary artery
    • Ross JJ, Jr., Mintz GS, Chandrasekaran K: Transthoracic two-dimensional high frequency (7.5 MHz) ultrasonic visualization of the distal left anterior descending coronary artery. J Am Coll Cardiol 1990;15:373-377.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 373-377
    • Ross Jr., J.J.1    Mintz, G.S.2    Chandrasekaran, K.3
  • 12
    • 0028364240 scopus 로고
    • Measurement of left anterior descending coronary artery flow velocities by transthoracic Doppler ultrasound
    • Kenny A, Wisbey CR, Shapiro LM: Measurement of left anterior descending coronary artery flow velocities by transthoracic Doppler ultrasound. Am J Cardiol 1994;73:1021-1022.
    • (1994) Am J Cardiol , vol.73 , pp. 1021-1022
    • Kenny, A.1    Wisbey, C.R.2    Shapiro, L.M.3
  • 13
    • 0032574674 scopus 로고    scopus 로고
    • Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography
    • Hozumi T, Yoshida K, Ogata Y, et al: Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography. Circulation 1998;97:1557-1562.
    • (1998) Circulation , vol.97 , pp. 1557-1562
    • Hozumi, T.1    Yoshida, K.2    Ogata, Y.3
  • 14
    • 0032962746 scopus 로고    scopus 로고
    • New noninvasive method for coronary flow reserve assessment: Contrast- Enhanced transthoracic second harmonic echo Doppler
    • Caiati C, Montaldo C, Zedda N, et al: New noninvasive method for coronary flow reserve assessment: Contrast-enhanced transthoracic second harmonic echo Doppler. Circulation 1999;99:771-778.
    • (1999) Circulation , vol.99 , pp. 771-778
    • Caiati, C.1    Montaldo, C.2    Zedda, N.3
  • 15
    • 0035312337 scopus 로고    scopus 로고
    • Physiologic assessment of coronary artery stenosis by coronary flow reserve measurements with transthoracic Doppler echocardiography: Comparison with exercise thallium-201 single piston emission computed tomography
    • Daimon M, Watanabe H, Yamagishi H, et al: Physiologic assessment of coronary artery stenosis by coronary flow reserve measurements with transthoracic Doppler echocardiography: Comparison with exercise thallium-201 single piston emission computed tomography. J Am Coll Cardiol 2001;37:1310-1315.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1310-1315
    • Daimon, M.1    Watanabe, H.2    Yamagishi, H.3
  • 16
    • 0032213330 scopus 로고    scopus 로고
    • Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: Comparison with invasive technique
    • Hozumi T, Yoshida K, Akasaka T, et al: Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: Comparison with invasive technique. J Am Coll Cardiol 1998;32:1251-1259.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1251-1259
    • Hozumi, T.1    Yoshida, K.2    Akasaka, T.3
  • 17
    • 0346794072 scopus 로고    scopus 로고
    • Validation of a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: Comparison with intracoronary Doppler flow wire
    • Caiati C, Montaldo C, Zedda N, et al: Validation of a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: Comparison with intracoronary Doppler flow wire. J Am Coll Cardiol 1999;34:1193-1200.
    • (1999) J Am Coll Cardiol , vol.34 , pp. 1193-1200
    • Caiati, C.1    Montaldo, C.2    Zedda, N.3
  • 18
    • 0029870998 scopus 로고    scopus 로고
    • Coronary flow velocity changes after intravenous dipyridamole infusion: Measurements using intravascular Doppler guide wire. A documentation of flow inhomogeneity
    • Voudris V, Manginas A, Vassilikos V, et al: Coronary flow velocity changes after intravenous dipyridamole infusion: Measurements using intravascular Doppler guide wire. A documentation of flow inhomogeneity. J Am Coll Cardiol 1996;27:1148-1155.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1148-1155
    • Voudris, V.1    Manginas, A.2    Vassilikos, V.3
  • 19
    • 0030297750 scopus 로고    scopus 로고
    • Variations in normal coronary vasodilatory reserve stratified by artery, gender, heart transplantation and coronary artery disease
    • Kern MJ, Bach RG, Mechem CJ, et al: Variations in normal coronary vasodilatory reserve stratified by artery, gender, heart transplantation and coronary artery disease. J Am Coll Cardiol 1996;28:1154-1160.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 1154-1160
    • Kern, M.J.1    Bach, R.G.2    Mechem, C.J.3
  • 20
    • 0026655142 scopus 로고
    • Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch coronary contrast catheters from digital and cine arteriograms
    • Koning G, van der Zwet PM, von Land CD, et al: Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch coronary contrast catheters from digital and cine arteriograms. Int J Card Imaging 1992;8:153-161.
    • (1992) Int J Card Imaging , vol.8 , pp. 153-161
    • Koning, G.1    Van Der Zwet, P.M.2    Von Land, C.D.3
  • 21
    • 0026785524 scopus 로고
    • Measuring progression and regression of coronary atherosclerosis in clinical trials: Problems and progress
    • Lesperance J, Waters D. Measuring progression and regression of coronary atherosclerosis in clinical trials: Problems and progress. Int J Card Imaging 1992;8:165-173.
    • (1992) Int J Card Imaging , vol.8 , pp. 165-173
    • Lesperance, J.1    Waters, D.2
  • 22
    • 0027219731 scopus 로고
    • Can the same edge-detection algorithm be applied to online and off-line analysis systems? Validation of a new cinefilm-based geometric coronary measurement software
    • Haase J, van der Linden MM, Di Mario C, et al: Can the same edge-detection algorithm be applied to online and off-line analysis systems? Validation of a new cinefilm-based geometric coronary measurement software. Am Heart J 1993;126:312-321.
    • (1993) Am Heart J , vol.126 , pp. 312-321
    • Haase, J.1    Van Der Linden, M.M.2    Di Mario, C.3
  • 23
    • 0026010975 scopus 로고
    • Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation
    • Iliceto S, Marangelli V, Memmola C, et al: Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation. Circulation 1991;83:61-69.
    • (1991) Circulation , vol.83 , pp. 61-69
    • Iliceto, S.1    Marangelli, V.2    Memmola, C.3
  • 24
    • 0029057256 scopus 로고
    • Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography. Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis
    • Redberg RF, Sobol Y, Chou TM, et al: Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography. Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis. Circulation 1995;92:190-196.
    • (1995) Circulation , vol.92 , pp. 190-196
    • Redberg, R.F.1    Sobol, Y.2    Chou, T.M.3
  • 25
    • 0024544514 scopus 로고
    • Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients
    • Demer LL, Gould KL, Goldstein RA, et al: Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients. Circulation 1989;79: 825-835.
    • (1989) Circulation , vol.79 , pp. 825-835
    • Demer, L.L.1    Gould, K.L.2    Goldstein, R.A.3
  • 26
    • 0026597278 scopus 로고
    • Usefulness and limitations of transesophageal echocardiography in the assessment of proximal coronary artery stenosis
    • Samdarshi TE, Nanda NC, Gatewood RP Jr., et al: Usefulness and limitations of transesophageal echocardiography in the assessment of proximal coronary artery stenosis. J Am Coll Cardiol 1992;19:572-580.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 572-580
    • Samdarshi, T.E.1    Nanda, N.C.2    Gatewood Jr., R.P.3
  • 27
    • 0023235671 scopus 로고
    • Relation of coronary artery stenosis and pressure gradient to exercise-induced ischemia before and after coronary angioplasty
    • Peterson RJ, King SB,3rd, Fajman WA, et al: Relation of coronary artery stenosis and pressure gradient to exercise-induced ischemia before and after coronary angioplasty. J Am Coll Cardiol 1987;10:253-260.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 253-260
    • Peterson, R.J.1    King III, S.B.2    Fajman, W.A.3
  • 28
    • 0027174944 scopus 로고
    • Use of translesional coronary flow velocity for interventional decisions in a patient with multiple intermediately severe coronary stenoses
    • Kern MJ, Flynn MS, Caracciolo EA, et al: Use of translesional coronary flow velocity for interventional decisions in a patient with multiple intermediately severe coronary stenoses. Cathet Cardiovasc Diagn 1993;29:148-153.
    • (1993) Cathet Cardiovasc Diagn , vol.29 , pp. 148-153
    • Kern, M.J.1    Flynn, M.S.2    Caracciolo, E.A.3
  • 29
    • 0030782368 scopus 로고    scopus 로고
    • Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the short- and long-term outcomes of coronary balloon angioplasty: The DEBATE Study (Doppler Endpoints Balloon Angioplasty Trial Europe)
    • Serruys PW, di Mario C, Piek J, et al: Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the short-and long-term outcomes of coronary balloon angioplasty: The DEBATE Study (Doppler Endpoints Balloon Angioplasty Trial Europe). Circulation 1997;96:3369-3377.
    • (1997) Circulation , vol.96 , pp. 3369-3377
    • Serruys, P.W.1    Di Mario, C.2    Piek, J.3
  • 30
    • 0023720864 scopus 로고
    • Twelve-year follow-up of survival in the randomized European Coronary Surgery Study
    • Varnauskas E: Twelve-year follow-up of survival in the randomized European Coronary Surgery Study. N Engl J Med 1988;319:332-337.
    • (1988) N Engl J Med , vol.319 , pp. 332-337
    • Varnauskas, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.