Volumn 26 VI, Issue , 2004, Pages 4149-4152

A batch-manufacturable uniform current density metallic-shell hemispherical microelectrode

Author keywords

Edge effect; Hemisphere electrode; Neuromuscular stimulation; Uniform current density

Indexed keywords

COMPUTER SIMULATION; ELECTRIC FIELD EFFECTS; MATHEMATICAL MODELS; MICROELECTRODES; MICROELECTROMECHANICAL DEVICES; NEUROLOGY; SILICA;

EID: 11144344183     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (6)
  • 1
    • 0028447149 scopus 로고
    • Solid-state microsensors for cortical nerve recordings
    • K. Najafi, "Solid-State Microsensors for Cortical Nerve Recordings," IEEE Engineering in Medicine and Biology Magazine, Vol. 13, pp. 375-387, 1994.
    • (1994) IEEE Engineering in Medicine and Biology Magazine , vol.13 , pp. 375-387
    • Najafi, K.1
  • 2
    • 0034884441 scopus 로고    scopus 로고
    • Single-unit neural recording with active microelectrode arrays
    • B. Quing, and K. D. Wise, "Single-Unit Neural Recording with Active Microelectrode Arrays," IEEE Transactions on Biomedical Engineering, Vol. 48, pp. 911-920, 2001.
    • (2001) IEEE Transactions on Biomedical Engineering , vol.48 , pp. 911-920
    • Quing, B.1    Wise, K.D.2
  • 4
    • 0025112572 scopus 로고
    • Uniformity of current density under stimulating electrodes
    • Y. Kim, H. G. Zieber, and F. E. Wang, "Uniformity of Current Density under Stimulating Electrodes," Crit. Rev. Biom. Eng., Vol. 17, Issue 6, pp. 585-619, 1990.
    • (1990) Crit. Rev. Biom. Eng. , vol.17 , Issue.6 , pp. 585-619
    • Kim, Y.1    Zieber, H.G.2    Wang, F.E.3
  • 5
    • 0026153583 scopus 로고
    • In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodes
    • M. F. Susserman, F. A. Spelman, and J. T. Rubinstein, "In Vitro Measurement and Characterization of Current Density Profiles Produced by Nonrecessed, Simple Recessed, and Radially Varying Recessed Stimulating Electrodes," IEEE Transaction son Biomedical Engineering, Vol. 38, pp. 401-408, 1991.
    • (1991) IEEE Transaction Son Biomedical Engineering , vol.38 , pp. 401-408
    • Susserman, M.F.1    Spelman, F.A.2    Rubinstein, J.T.3
  • 6
    • 0026890252 scopus 로고
    • A minimum profile uniform current density electrode
    • D. A. Ksienski, "A Minimum Profile Uniform Current Density Electrode," IEEE Trans. on Biomedical Engineering, Vol. 39, No. 7, pp. 682-692, 1992.
    • (1992) IEEE Trans. on Biomedical Engineering , vol.39 , Issue.7 , pp. 682-692
    • Ksienski, D.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.