메뉴 건너뛰기




Volumn 26 V, Issue , 2004, Pages 3773-3776

In vitro evaluation of control strategies for an artificial vasculature device

Author keywords

And mock circulation; Cardiac assist; Counterpulsation; Myocardial recovery

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; DATA REDUCTION; MICROCIRCULATION; PERSONAL COMPUTERS; POSITION CONTROL;

EID: 11144342338     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (16)
  • 1
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure
    • E.A. Rose, A.C. Gelijns, A.J. Moskowitz, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N. Engl. J. Meet., 345:1435-1493, 2001.
    • (2001) N. Engl. J. Meet. , vol.345 , pp. 1435-1493
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 3
    • 0035100454 scopus 로고    scopus 로고
    • Advanced mechanical circulatory support with the HeartMate left ventricular assist device in the year 2000
    • J.W. Long. Advanced mechanical circulatory support with the HeartMate left ventricular assist device in the year 2000. Ann Thorac Surg, 71:S176-84, 2001.
    • (2001) Ann Thorac Surg , vol.71
    • Long, J.W.1
  • 4
    • 0035107143 scopus 로고    scopus 로고
    • Research and development of an implantable, axial-flow left ventricular assist device: The Jarvik 2000 Heart
    • O.H. Frazier, T.J. Myers, R.K. Jarvik, et al. Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 Heart. Am Thorac Surg, 71 :S125-32, 2001.
    • (2001) Am Thorac Surg , vol.71
    • Frazier, O.H.1    Myers, T.J.2    Jarvik, R.K.3
  • 6
    • 0032404106 scopus 로고    scopus 로고
    • Left ventricular assist device and the failing heart: A bridge to recovery, a permanent assist device, or a bridge too far?
    • D.L. Mann and J.T. Willerson. Left ventricular assist device and the failing heart: a bridge to recovery, a permanent assist device, or a bridge too far? Circulation, 97:2367-69, 1998.
    • (1998) Circulation , vol.97 , pp. 2367-2369
    • Mann, D.L.1    Willerson, J.T.2
  • 7
    • 0033508918 scopus 로고    scopus 로고
    • Mechanical circulatory devices for the treatment of heart failure
    • T. Mussivand. Mechanical circulatory devices for the treatment of heart failure. J Card Surg, 13:218-28, 1998.
    • (1998) J Card Surg , vol.13 , pp. 218-228
    • Mussivand, T.1
  • 13
    • 0348230939 scopus 로고    scopus 로고
    • Characterization of an adult mock circulation for testing cardiac support devices
    • G. M. Pantalos, K. J. Gillars, D. L. Ewert, G. A. Giridharan, and S. C. Koenig, "Characterization of an adult mock circulation for testing cardiac support devices", ASAIO Journal, vol 50, pp. 37-46, 2004.
    • (2004) ASAIO Journal , vol.50 , pp. 37-46
    • Pantalos, G.M.1    Gillars, K.J.2    Ewert, D.L.3    Giridharan, G.A.4    Koenig, S.C.5
  • 14
    • 11144340542 scopus 로고    scopus 로고
    • Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices
    • in press
    • S.C. Koenig, C. Woolard, G.D. Drew, et al. Integrated data acquisition system for medical device testing and physiology research in compliance with Good Laboratory Practices Biomed. Instr. & Tech. (in press).
    • Biomed. Instr. & Tech.
    • Koenig, S.C.1    Woolard, C.2    Drew, G.D.3
  • 16
    • 2442599564 scopus 로고    scopus 로고
    • HEART: An automated beat-to-beat cardiovascular analysis package using Matlab™
    • in press
    • M. J. Schroeder, B. Perrrault, D. L. Ewert, and S. C. Koenig, "HEART: An automated beat-to-beat cardiovascular analysis package using Matlab™", Comp. Biol. & Med. (in press).
    • Comp. Biol. & Med.
    • Schroeder, M.J.1    Perrrault, B.2    Ewert, D.L.3    Koenig, S.C.4