메뉴 건너뛰기




Volumn 117, Issue 2-3, 2005, Pages 89-102

Evaluation of the validity of the UN SADT H.4 test for solid organic peroxides and self-reactive substances

Author keywords

Numerical simulations; SADT of solids; Scale up procedure; Transport regulations; UN H.4 test (HAST)

Indexed keywords

SELF-REACTIVE SUBSTANCES; SOLID ORGANIC PEROXIDE;

EID: 11144329626     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2004.09.028     Document Type: Article
Times cited : (31)

References (10)
  • 3
    • 0037473765 scopus 로고    scopus 로고
    • Influence of heat transport mechanisms on transport classification by SADT-measurement as measured by the Dewar-method
    • H. Fierz Influence of heat transport mechanisms on transport classification by SADT-measurement as measured by the Dewar-method J. Hazard. Mater. 96 2-3 2003 121
    • (2003) J. Hazard. Mater. , vol.96 , Issue.23 , pp. 121
    • Fierz, H.1
  • 4
    • 0142056976 scopus 로고    scopus 로고
    • Some comments on the paper of H. Fierz: Influence of heat transport mechanisms on transport classification by SADT-measurement as measured by the Dewar-method
    • M. Malow, U. Krause, and K.D. Wehrstedt Some comments on the paper of H. Fierz: influence of heat transport mechanisms on transport classification by SADT-measurement as measured by the Dewar-method J. Hazard. Mater. 103 1-2 2003 169
    • (2003) J. Hazard. Mater. , vol.103 , Issue.12 , pp. 169
    • Malow, M.1    Krause, U.2    Wehrstedt, K.D.3
  • 5
    • 11144305335 scopus 로고    scopus 로고
    • Comments on the Letter to the Editor from M. Malow, U. Krause and K.D. Wehrstedt concerning the paper of H. Fierz: Influence of heat transport mechanism on transport classification by SADT-measurement as measured by the Dewar-method
    • H. Fierz Comments on the Letter to the Editor from M. Malow, U. Krause and K.D. Wehrstedt concerning the paper of H. Fierz: influence of heat transport mechanism on transport classification by SADT-measurement as measured by the Dewar-method J. Hazard. Mater. 103 1-2 2003 175
    • (2003) J. Hazard. Mater. , vol.103 , Issue.12 , pp. 175
    • Fierz, H.1
  • 6
    • 0000830099 scopus 로고
    • Use of the accelerating rate calorimeter and the thermal activity monitor to estimate stability temperatures
    • M.W. Whitmore, and J.K. Wilberforce Use of the accelerating rate calorimeter and the thermal activity monitor to estimate stability temperatures J. Loss Prev. Process Ind. 6 2 1993 95
    • (1993) J. Loss Prev. Process Ind. , vol.6 , Issue.2 , pp. 95
    • Whitmore, M.W.1    Wilberforce, J.K.2
  • 7
    • 0026170036 scopus 로고
    • Safe operation of a batch reactor: Safe storage of organic peroxides in supply vessels
    • M. Steensma, and K.R. Westerterp Safe operation of a batch reactor: safe storage of organic peroxides in supply vessels Chem. Eng. Technol. 14 1991 147
    • (1991) Chem. Eng. Technol. , vol.14 , pp. 147
    • Steensma, M.1    Westerterp, K.R.2
  • 8
    • 84983833841 scopus 로고
    • Thermal explosion of explosives and propellants. A review
    • A.G. Merzhanov, and V.G. Abramov Thermal explosion of explosives and propellants. A review Propellants Explosives 6 1981 130
    • (1981) Propellants Explosives , vol.6 , pp. 130
    • Merzhanov, A.G.1    Abramov, V.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.