메뉴 건너뛰기




Volumn 27, Issue 1, 2005, Pages 90-93

In-vitro study on the relationship between progressive sinotubular junction dilatation and aortic regurgitation for several stentless aortic valve substitutes

Author keywords

Allograft; Autograft; Implantation technique; Sinutubular junction; Stentless porcine valve

Indexed keywords

AORTA GRAFT; AORTA ROOT; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; AUTOGRAFT; BIOPROSTHESIS; CONFERENCE PAPER; CORRELATION ANALYSIS; DEVICE; DISEASE COURSE; IMPLANTATION; IN VITRO STUDY; LUNG HILUS; MEASUREMENT; NONHUMAN; PRIORITY JOURNAL; VASODILATATION; XENOGRAFT;

EID: 11144326818     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2004.09.026     Document Type: Conference Paper
Times cited : (15)

References (18)
  • 1
    • 0014252103 scopus 로고
    • Clinical use of heterografts for replacement of the aortic valve
    • J.P. Binet, A. Carpentier, and J. Langlois Clinical use of heterografts for replacement of the aortic valve J Thorac Cardiovasc Surg 55 2 1968 238 242
    • (1968) J Thorac Cardiovasc Surg , vol.55 , Issue.2 , pp. 238-242
    • Binet, J.P.1    Carpentier, A.2    Langlois, J.3
  • 2
    • 0032451626 scopus 로고    scopus 로고
    • Carpentier-Edwards standard porcine bioprosthesis: A 21-year experience
    • W.R. Jamieson, L.H. Burr, A.I. Munro, and R.T. Miyagishima Carpentier-Edwards standard porcine bioprosthesis: a 21-year experience Ann Thorac Surg 66 6 1998 S40 S43
    • (1998) Ann Thorac Surg , vol.66 , Issue.6
    • Jamieson, W.R.1    Burr, L.H.2    Munro, A.I.3    Miyagishima, R.T.4
  • 4
    • 0021796979 scopus 로고
    • Implantation of a xenogeneic stentless aortic bioprosthesis. First experience
    • H.H. Sievers, P.E. Lange, and A. Bernhard Implantation of a xenogeneic stentless aortic bioprosthesis. First experience Thorac Cardiovasc Surg 33 4 1985 225 226
    • (1985) Thorac Cardiovasc Surg , vol.33 , Issue.4 , pp. 225-226
    • Sievers, H.H.1    Lange, P.E.2    Bernhard, A.3
  • 5
    • 0026351393 scopus 로고
    • Unstented and partial stented bioprostheses for aortic valve replacement-up to 6 years of follow-up
    • H.H. Sievers, M. Mahmoodi, P. Marquardt, U. Nellessen, M. Höfig, W. Angell, and A. Bernhard Unstented and partial stented bioprostheses for aortic valve replacement-up to 6 years of follow-up J Card Surg 6 4 1991 600 605
    • (1991) J Card Surg , vol.6 , Issue.4 , pp. 600-605
    • Sievers, H.H.1    Mahmoodi, M.2    Marquardt, P.3    Nellessen, U.4    Höfig, M.5    Angell, W.6    Bernhard, A.7
  • 6
    • 0021087647 scopus 로고
    • Dimensions of the great arteries, semilunar valve roots, and right ventricular outflow tract during growth: Normative angiocardiographic data
    • H.H. Sievers, D.G. Onnasch, P.E. Lange, A. Bernhard, and P.H. Heintzen Dimensions of the great arteries, semilunar valve roots, and right ventricular outflow tract during growth: normative angiocardiographic data Pediatr Cardiol 4 3 1983 189 196
    • (1983) Pediatr Cardiol , vol.4 , Issue.3 , pp. 189-196
    • Sievers, H.H.1    Onnasch, D.G.2    Lange, P.E.3    Bernhard, A.4    Heintzen, P.H.5
  • 7
    • 0032311286 scopus 로고    scopus 로고
    • Aortic valve replacement with stentless porcine bioprostheses
    • T. David Aortic valve replacement with stentless porcine bioprostheses J Card Surg 13 5 1998 344 351
    • (1998) J Card Surg , vol.13 , Issue.5 , pp. 344-351
    • David, T.1
  • 8
    • 0027264909 scopus 로고
    • Time course of dimension and function of the autologous pulmonary root in the aortic position
    • H.H. Sievers, R. Leyh, R. Loose, M. Guha, A. Petry, and A. Bernhard Time course of dimension and function of the autologous pulmonary root in the aortic position J Thorac Cardiovasc Surg 105 5 1993 775 780
    • (1993) J Thorac Cardiovasc Surg , vol.105 , Issue.5 , pp. 775-780
    • Sievers, H.H.1    Leyh, R.2    Loose, R.3    Guha, M.4    Petry, A.5    Bernhard, A.6
  • 11
    • 0021796979 scopus 로고
    • Implantation of a xenogeneic stentless aortic bioprosthesis. First experience
    • H.H. Sievers, P.E. Lange, and A. Bernhard Implantation of a xenogeneic stentless aortic bioprosthesis. First experience Thorac Cardiovasc Surg 33 4 1985 225 226
    • (1985) Thorac Cardiovasc Surg , vol.33 , Issue.4 , pp. 225-226
    • Sievers, H.H.1    Lange, P.E.2    Bernhard, A.3
  • 13
    • 0036356660 scopus 로고    scopus 로고
    • Transvalvular velocities after full aortic root replacement: Results from a prospective randomized trial between the homograft and the Medtronic Freestyle bioprosthesis
    • G. Melina, A. Mitchell, M. Amrani, A. Khaghani, and M.H. Yacoub Transvalvular velocities after full aortic root replacement: results from a prospective randomized trial between the homograft and the Medtronic Freestyle bioprosthesis J Heart Valve Dis 11 1 2002 54 58
    • (2002) J Heart Valve Dis , vol.11 , Issue.1 , pp. 54-58
    • Melina, G.1    Mitchell, A.2    Amrani, M.3    Khaghani, A.4    Yacoub, M.H.5
  • 14
    • 0035702297 scopus 로고    scopus 로고
    • Midterm survival of stented versus stentless valves: Does concomitant coronary artery bypass grafting impact survival?
    • D.F. del Rizzo, D. Freed, A. Abdoh, D. Doty, B.S. Goldman, W.R. Jamieson, and S. Westaby Midterm survival of stented versus stentless valves: does concomitant coronary artery bypass grafting impact survival? Semin Thorac Cardiovasc Surg 13 4 Suppl 1 2001 148 155
    • (2001) Semin Thorac Cardiovasc Surg , vol.13 , Issue.41 , pp. 148-155
    • Del Rizzo, D.F.1    Freed, D.2    Abdoh, A.3    Doty, D.4    Goldman, B.S.5    Jamieson, W.R.6    Westaby, S.7
  • 15
    • 0035700383 scopus 로고    scopus 로고
    • Analysis of explants and causes of mortality during long-term follow-up of the Toronto stentless porcine valve
    • Y. Shargall, B. Goldman, G. Christakis, and T. David Analysis of explants and causes of mortality during long-term follow-up of the Toronto stentless porcine valve Semin Thorac Cardiovasc Surg 13 4 Suppl 1 2001 106 112
    • (2001) Semin Thorac Cardiovasc Surg , vol.13 , Issue.41 , pp. 106-112
    • Shargall, Y.1    Goldman, B.2    Christakis, G.3    David, T.4
  • 17
    • 17644429454 scopus 로고    scopus 로고
    • Bicuspid aortic valves are associated with aortic dilatation out of proportion to coexistent valvular lesions
    • M.G. Keane, S.E. Wiegers, T. Plappert, A. Pochettino, J.E. Bavaria, and M.G. Sutton Bicuspid aortic valves are associated with aortic dilatation out of proportion to coexistent valvular lesions Circulation 102 19 Suppl 3 2000 III35 III39
    • (2000) Circulation , vol.102 , Issue.193
    • Keane, M.G.1    Wiegers, S.E.2    Plappert, T.3    Pochettino, A.4    Bavaria, J.E.5    Sutton, M.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.