메뉴 건너뛰기




Volumn 27, Issue 12, 2004, Pages 1610-1614

Two-year performance of a preshaped lead for left ventricular stimulation

Author keywords

Capture threshold; Cardiac resynchronization therapy; Lead impedance; Left ventricular stimulation; Sensing threshold

Indexed keywords

ADULT; AGED; ARTICLE; CARDIAC RESYNCHRONIZATION THERAPY; CELL SYNCHRONIZATION; CORONARY SINUS; FEMALE; HEART CATHETERIZATION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE PERFORMANCE; HUMAN; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; NERVE STIMULATION; PHRENIC NERVE; TECHNIQUE;

EID: 11144298695     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2004.00693.x     Document Type: Article
Times cited : (17)

References (14)
  • 1
    • 0032420568 scopus 로고    scopus 로고
    • Acute hemodynamic effects of biventricularDDD pacing in patients with end-stage heart failure
    • Leclercq C, Cazeau S, Le Breton H, et al. Acute hemodynamic effects of biventricularDDD pacing in patients with end-stage heart failure. J Am Coll Cardiol 1998; 32:1825-1831.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1825-1831
    • Leclercq, C.1    Cazeau, S.2    Le Breton, H.3
  • 2
    • 0037151656 scopus 로고    scopus 로고
    • Tissue Doppler imaging predicts improved systolic performance and reversed left ventricular remodeling during long-term cardiac resynchronization therapy
    • Søgaard P, Egeblad H, Kim WY, et al. Tissue Doppler imaging predicts improved systolic performance and reversed left ventricular remodeling during long-term cardiac resynchronization therapy. J Am Coll Cardiol 2002; 40:723-730.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 723-730
    • Søgaard, P.1    Egeblad, H.2    Kim, W.Y.3
  • 3
    • 0035932533 scopus 로고    scopus 로고
    • Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay
    • Cazeau S, Leclercq C, Lavergne T, et al. for the multisite stimulation in cardiomyopathies (MUSTIC) study investigators. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med 2001; 344:873-880.
    • (2001) N Engl J Med , vol.344 , pp. 873-880
    • Cazeau, S.1    Leclercq, C.2    Lavergne, T.3
  • 4
    • 0037071808 scopus 로고    scopus 로고
    • Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure
    • Abraham WT, Fisher WG, Smith AL, et al. for the MIRACLE study group. Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med 2002; 346:1845-1853.
    • (2002) N Engl J Med , vol.346 , pp. 1845-1853
    • Abraham, W.T.1    Fisher, W.G.2    Smith, A.L.3
  • 5
    • 0034828176 scopus 로고    scopus 로고
    • Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: Technical aspects
    • Alonso C, Leclercq C, d'Allonnes FR, et al. Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: Technical aspects. Heart 2001; 86:405-410.
    • (2001) Heart , vol.86 , pp. 405-410
    • Alonso, C.1    Leclercq, C.2    D'Allonnes, F.R.3
  • 6
    • 0036189128 scopus 로고    scopus 로고
    • Left heart pacing-experience with several types of coronary vein leads
    • Hansky B, Vogt J, Gueldner H, et al. Left heart pacing-experience with several types of coronary vein leads. J Interv Card Electrophysiol 2002; 6:71-75.
    • (2002) J Interv Card Electrophysiol , vol.6 , pp. 71-75
    • Hansky, B.1    Vogt, J.2    Gueldner, H.3
  • 7
    • 0034231832 scopus 로고    scopus 로고
    • Initial United Kingdom experience with the use of permanent, biventricular pacemakers: Implantation procedure and technical considerations
    • Walker S, Levy T, Rex S, et al. Initial United Kingdom experience with the use of permanent, biventricular pacemakers: Implantation procedure and technical considerations. Europace 2000; 2:233-239.
    • (2000) Europace , vol.2 , pp. 233-239
    • Walker, S.1    Levy, T.2    Rex, S.3
  • 8
    • 0033674984 scopus 로고    scopus 로고
    • Performance of a new steroid-eluting coronary sinus lead designed for left ventricular pacing
    • Achtelik M, Bocchiardo M, Trappe HJ, et al. for the VENTAK CHF/CONTAK CD Clinical Investigation Study Group. Performance of a new steroid-eluting coronary sinus lead designed for left ventricular pacing. PACE 2000; 23:1741-1743.
    • (2000) PACE , vol.23 , pp. 1741-1743
    • Achtelik, M.1    Bocchiardo, M.2    Trappe, H.J.3
  • 9
    • 0036775036 scopus 로고    scopus 로고
    • Implantation techniques and chronic lead parameters of biventricular pacing dual-chamber defibrillators
    • Daoud EG, Kalbfleisch SJ, Hummel JD, et al. Implantation techniques and chronic lead parameters of biventricular pacing dual-chamber defibrillators. J Cardiovasc Electrophysiol 2002; 13:964-970.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 964-970
    • Daoud, E.G.1    Kalbfleisch, S.J.2    Hummel, J.D.3
  • 10
    • 0037378641 scopus 로고    scopus 로고
    • Short and long-term single-centre experience with an S-shaped unipolar lead for left ventricular pacing
    • Fatemi M, Etienne Y, Guard M, et al. Short and long-term single-centre experience with an S-shaped unipolar lead for left ventricular pacing. Europace 2003; 5:207-211.
    • (2003) Europace , vol.5 , pp. 207-211
    • Fatemi, M.1    Etienne, Y.2    Guard, M.3
  • 11
    • 11144286491 scopus 로고    scopus 로고
    • Long-term stability of left ventricular pacing threshold in cardiac resynchronization therapy - A PACMAN substudy
    • Morgan JM, Paisey JR, Duby C, et al. Long-term stability of left ventricular pacing threshold in cardiac resynchronization therapy - a PACMAN substudy. Heart Rhythm 2004; 1(Suppl.):S217.
    • (2004) Heart Rhythm , vol.1 , Issue.SUPPL.
    • Morgan, J.M.1    Paisey, J.R.2    Duby, C.3
  • 12
    • 0346665531 scopus 로고    scopus 로고
    • Long-term experience with a preshaped left ventricular pacing lead
    • Ollitrault J, Ritter P, Mabo P, et al. Long-term experience with a preshaped left ventricular pacing lead. PACE 2003; 26:185-188.
    • (2003) PACE , vol.26 , pp. 185-188
    • Ollitrault, J.1    Ritter, P.2    Mabo, P.3
  • 13
    • 0037356431 scopus 로고    scopus 로고
    • Elevations in ventricular pacing threshold with the use of the Y adaptor: Implications for biventricular pacing
    • Rho RW, Patel VV, Gerstenfeld EP, et al. Elevations in ventricular pacing threshold with the use of the Y adaptor: Implications for biventricular pacing. PACE 2003; 26:747-751.
    • (2003) PACE , vol.26 , pp. 747-751
    • Rho, R.W.1    Patel, V.V.2    Gerstenfeld, E.P.3
  • 14
    • 0141519158 scopus 로고    scopus 로고
    • Simple access to the coronary venous system for left ventricular pacing
    • Sayad DE, Sawar A, Curkovic V, et al. Simple access to the coronary venous system for left ventricular pacing. PACE 2003; 26:1856-1858.
    • (2003) PACE , vol.26 , pp. 1856-1858
    • Sayad, D.E.1    Sawar, A.2    Curkovic, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.