메뉴 건너뛰기




Volumn 26 II, Issue , 2004, Pages 1128-1131

An inverse methodology for high frequency RF head coil design with pre-emphasized B1 field in MRI

Author keywords

FDTD; Inverse methodology; MRI; Pre emphasis

Indexed keywords

BIOLOGICAL ORGANS; ELECTRIC COILS; ELECTROMAGNETIC FIELD EFFECTS; FINITE DIFFERENCE METHOD; GREEN'S FUNCTION; HARMONIC ANALYSIS; NUCLEAR MAGNETIC RESONANCE; PERTURBATION TECHNIQUES; POLARIZATION; RADIO WAVES; SIGNAL PROCESSING; TIME DOMAIN ANALYSIS; TISSUE;

EID: 11144294741     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (13)
  • 1
    • 85092119588 scopus 로고    scopus 로고
    • Radio frequency magnetic field mapping of 3 T birdcage coils: Experimental and theoretical dependence on sample properties
    • M. Alecci, C. M. Collins, M. B. Smith and P. Jezzard, "Radio Frequency Magnetic Field Mapping of 3 T birdcage coils: Experimental and Theoretical Dependence on Sample properties", Magn. Reson. Med. Vol 46, pp. 1037-1042, 2002.
    • (2002) Magn. Reson. Med. , vol.46 , pp. 1037-1042
    • Alecci, M.1    Collins, C.M.2    Smith, M.B.3    Jezzard, P.4
  • 2
    • 0001890040 scopus 로고    scopus 로고
    • Sample-induced RF perturbations in high-field, high-resolution NMR spectroscopy
    • S. Crazier, I. M. Brereton, F.O. Zelaya, W.U. Roffmann and D.M. Doddrell, "Sample-Induced RF Perturbations in High-Field, High-Resolution NMR Spectroscopy", J Magn Reson 1997;vol 126, pp. 39-47
    • (1997) J Magn Reson , vol.126 , pp. 39-47
    • Crazier, S.1    Brereton, I.M.2    Zelaya, F.O.3    Roffmann, W.U.4    Doddrell, D.M.5
  • 4
    • 11144302488 scopus 로고
    • "Cavity resonator with improved magnetic field uniformity for high frequency operation and reduced dielectric heating in NMR imaging devices", U.S. Patent 4 751 464, June 14
    • J. F. Bridges, "Cavity resonator with improved magnetic field uniformity for high frequency operation and reduced dielectric heating in NMR imaging devices", U.S. Patent 4 751 464, June 14, 1988.
    • (1988)
    • Bridges, J.F.1
  • 6
    • 0038150142 scopus 로고    scopus 로고
    • A microstrip transmission line volume coil for human head MR imaging at 4P
    • X. L. Zhang, K. Ugurbill, and W. Chen, "A microstrip transmission line volume coil for human head MR imaging at 4P", J. Magn. Reson. vol. 161,pp. 242-251, 2003.
    • (2003) J. Magn. Reson. , vol.161 , pp. 242-251
    • Zhang, X.L.1    Ugurbill, K.2    Chen, W.3
  • 7
    • 0036134007 scopus 로고    scopus 로고
    • A Time-harmonic inverse methodology for the design of RF coils in MRI
    • B. G. Lawrence, S. Crazier, D. D. Yau, and D. M. Doddrell, "A Time-Harmonic Inverse Methodology for the Design of RF Coils in MRI" IEEE Trans. Biomed. Eng vol. 49, pp. 64-71, 2002
    • (2002) IEEE Trans. Biomed. Eng , vol.49 , pp. 64-71
    • Lawrence, B.G.1    Crazier, S.2    Yau, D.D.3    Doddrell, D.M.4
  • 8
    • 0036721443 scopus 로고    scopus 로고
    • An inverse design of an open, head/neck RF coil for MRI
    • B. G. Lawrence, S. Crazier, G. Cowin, D. D. and Yau, "An Inverse Design of an Open, Head/Neck RF Coil for MRI", IEEE Trans. Biomed vol. 49, pp. 1-7, 2002
    • (2002) IEEE Trans. Biomed , vol.49 , pp. 1-7
    • Lawrence, B.G.1    Crazier, S.2    Cowin, G.3    Yau, D.D.4
  • 11
    • 0024090850 scopus 로고
    • Minimum inductance coils
    • R. Turner, "Minimum inductance coils", J. Phys. E: Sci. Instrum., vol. 21, pp. 948-952, 1988
    • (1988) J. Phys. E: Sci. Instrum. , vol.21 , pp. 948-952
    • Turner, R.1
  • 13
    • 0032080159 scopus 로고    scopus 로고
    • 1-field in-homogeneity of shielded RF coils loaded with a human head
    • 1-field in-homogeneity of shielded RF coils loaded with a human head", IEEE Trans. Biomed. Eng., vol. 45, pp. 650-659, 1998
    • (1998) IEEE Trans. Biomed. Eng. , vol.45 , pp. 650-659
    • Chen, I.1    Feng, Z.2    Jin, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.