메뉴 건너뛰기




Volumn 29, Issue 6, 2004, Pages 544-548

The learning curve associated with a simulated ultrasound-guided interventional task by inexperienced anesthesia residents

Author keywords

Education; Nerve block; Turkey breast model.; Ultrasound

Indexed keywords

ACCURACY; ANESTHESIA; ARTICLE; ECHOGRAPHY; HUMAN; NERVE BLOCK; PRIORITY JOURNAL; RESIDENCY EDUCATION; RESIDENT; SIMULATION; ULTRASOUND;

EID: 11144291038     PISSN: 10987339     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rapm.2004.08.014     Document Type: Article
Times cited : (200)

References (7)
  • 2
    • 11144303125 scopus 로고    scopus 로고
    • The use of turkey breast and stuffed olives as a soft tissue model for the teaching and practice of ultrasound guided interventional procedures
    • R.C. Beese, S. Lowe The use of turkey breast and stuffed olives as a soft tissue model for the teaching and practice of ultrasound guided interventional procedures Eur J Ultrasound 7 1998 S12
    • (1998) Eur J Ultrasound , vol.7
    • Beese, R.C.1    Lowe, S.2
  • 3
    • 0035491311 scopus 로고    scopus 로고
    • Lateral approach biopsy adapter: Accuracy on an upright unit in a turkey breast model
    • C. Lehman, H. Sieler-Gutierrez, D. Georgian-Smith Lateral approach biopsy adapter Accuracy on an upright unit in a turkey breast model AJR Am J Roentgenol 177 2001 897 899
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 897-899
    • Lehman, C.1    Sieler-Gutierrez, H.2    Georgian-Smith, D.3
  • 4
    • 0030770302 scopus 로고    scopus 로고
    • Evaluation of 14 and 11 gauge directional, vacuum-assisted biopsy probes and 14 gauge biopsy guns in a breast parenchymal model
    • W.A. Berg, T.L. Krebs, C. Campssi, L.S. Magder, C.C. Sun Evaluation of 14 and 11 gauge directional, vacuum-assisted biopsy probes and 14 gauge biopsy guns in a breast parenchymal model Radiology 205 1997 203 208
    • (1997) Radiology , vol.205 , pp. 203-208
    • Berg, W.A.1    Krebs, T.L.2    Campssi, C.3    Magder, L.S.4    Sun, C.C.5
  • 5
    • 0031902060 scopus 로고    scopus 로고
    • Specimen weights obtained with 14 and 11 gauge breast biopsy probes
    • F. Burbank Specimen weights obtained with 14 and 11 gauge breast biopsy probes Radiology 208 1998 269 270
    • (1998) Radiology , vol.208 , pp. 269-270
    • Burbank, F.1
  • 6
    • 0041963046 scopus 로고    scopus 로고
    • Brachial plexus examination and localization using ultrasound and electrical stimulation
    • A. Perlas, V. Chan, M. Simons Brachial plexus examination and localization using ultrasound and electrical stimulation Anesthesiology 99 2003 429 435
    • (2003) Anesthesiology , vol.99 , pp. 429-435
    • Perlas, A.1    Chan, V.2    Simons, M.3
  • 7
    • 0029879154 scopus 로고    scopus 로고
    • The regional anesthesia "learning curve." What is the minimum number of epidural and spinal blocks to reach consistency?
    • D.J. Kopacz, J.M. Neal, J.E. Pollock The regional anesthesia "learning curve." What is the minimum number of epidural and spinal blocks to reach consistency? Reg Anesth 21 1996 182 190
    • (1996) Reg Anesth , vol.21 , pp. 182-190
    • Kopacz, D.J.1    Neal, J.M.2    Pollock, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.