메뉴 건너뛰기




Volumn 129, Issue 1, 2005, Pages 146-150

A new mechanical connector for distal coronary artery anastomoses in coronary artery bypass grafting: A randomized, controlled study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTERY ANASTOMOSIS; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORONARY ARTERY; CORONARY ARTERY BYPASS GRAFT; DEVICE; FEMALE; FOLLOW UP; GRAFT PATENCY; HUMAN; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RANDOMIZATION; RANDOMIZED CONTROLLED TRIAL; TREATMENT OUTCOME; VASCULAR PATENCY; VEIN GRAFT;

EID: 11144280461     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2004.02.027     Document Type: Article
Times cited : (18)

References (16)
  • 1
    • 0034849364 scopus 로고    scopus 로고
    • Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses
    • F.S. Eckstein, L.F. Bonilla, L. Englberger, E. Stauffer, T.A. Berg, J. Schmidli Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses Ann Thorac Surg 72 2001 S995 8
    • (2001) Ann Thorac Surg , vol.72
    • Eckstein, F.S.1    Bonilla, L.F.2    Englberger, L.3    Stauffer, E.4    Berg, T.A.5    Schmidli, J.6
  • 2
    • 0036263476 scopus 로고    scopus 로고
    • Angiographic results after the use of a sutureless aortic connector for proximal vein graft anastomoses
    • L. Wiklund, M. Bugge, E. Berglin Angiographic results after the use of a sutureless aortic connector for proximal vein graft anastomoses Ann Thorac Surg 73 2002 1993 1994
    • (2002) Ann Thorac Surg , vol.73 , pp. 1993-1994
    • Wiklund, L.1    Bugge, M.2    Berglin, E.3
  • 3
    • 0042164557 scopus 로고    scopus 로고
    • Clinical, angiographic, and interventional follow-up of patients with aortic-saphenous vein graft connectors
    • J.H. Traverse, M.R. Mooney, W.R. Pedersen, J.D. Madison, T.F. Flavin, V.R. Kshettry Clinical, angiographic, and interventional follow-up of patients with aortic-saphenous vein graft connectors Circulation 108 2003 452 456
    • (2003) Circulation , vol.108 , pp. 452-456
    • Traverse, J.H.1    Mooney, M.R.2    Pedersen, W.R.3    Madison, J.D.4    Flavin, T.F.5    Kshettry, V.R.6
  • 4
    • 0036189143 scopus 로고    scopus 로고
    • An experimental model of saphenous vein-to-coronary artery anastomosis with the St: Jude Medical stainless steel connector
    • H.V. Schaff, K.J. Zehr, L.F. Bonilla, L.H. Brennecke, T. Berg, R. Cornelius An experimental model of saphenous vein-to-coronary artery anastomosis with the St Jude Medical stainless steel connector Ann Thorac Surg 73 2002 830 835
    • (2002) Ann Thorac Surg , vol.73 , pp. 830-835
    • Schaff, H.V.1    Zehr, K.J.2    Bonilla, L.F.3    Brennecke, L.H.4    Berg, T.5    Cornelius, R.6
  • 5
    • 0035941966 scopus 로고    scopus 로고
    • Sutureless mechanical anastomosis of a saphenous vein graft to a coronary artery with a new connector device
    • F.S. Eckstein, L.F. Bonilla, B. Meyer, T.A. Berg, P.P. Neidhart, J. Schmidli Sutureless mechanical anastomosis of a saphenous vein graft to a coronary artery with a new connector device Lancet 357 2001 921 932
    • (2001) Lancet , vol.357 , pp. 921-932
    • Eckstein, F.S.1    Bonilla, L.F.2    Meyer, B.3    Berg, T.A.4    Neidhart, P.P.5    Schmidli, J.6
  • 6
    • 0037167654 scopus 로고    scopus 로고
    • First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG
    • F.S. Eckstein, L.F. Bonilla, L. Englberger, F. Eberli, S. Windecker, T.A. Berg First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG Circulation 106 12 Suppl 1 2002 I1 4
    • (2002) Circulation , vol.106 , Issue.121
    • Eckstein, F.S.1    Bonilla, L.F.2    Englberger, L.3    Eberli, F.4    Windecker, S.5    Berg, T.A.6
  • 8
    • 0000248167 scopus 로고    scopus 로고
    • An automated interrupted suturing device for coronary artery bypass grafting: Automated coronary anastomosis
    • H. Shennib, S.J. Korkola, N. Bousette, A. Giaid An automated interrupted suturing device for coronary artery bypass grafting: automated coronary anastomosis Ann Thorac Surg 17 2000 312 318
    • (2000) Ann Thorac Surg , vol.17 , pp. 312-318
    • Shennib, H.1    Korkola, S.J.2    Bousette, N.3    Giaid, A.4
  • 10
    • 0033931588 scopus 로고    scopus 로고
    • Assessment of patented coronary end-to-side anastomotic devices using micromechanical bonding
    • J.S. Scheltes, M. Heikens, P.V. Pistecky, C.J. van Andel, C. Borst Assessment of patented coronary end-to-side anastomotic devices using micromechanical bonding Ann Thorac Surg 70 2000 218 221
    • (2000) Ann Thorac Surg , vol.70 , pp. 218-221
    • Scheltes, J.S.1    Heikens, M.2    Pistecky, P.V.3    Van Andel, C.J.4    Borst, C.5
  • 12
    • 0030245599 scopus 로고    scopus 로고
    • Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years
    • G.M. Fitzgibbon, H.P. Kafka, A.J. Leach, W.J. Keon, G.D. Hooper, J.R. Burton Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years J Am Coll Cardiol 28 1996 616 626
    • (1996) J Am Coll Cardiol , vol.28 , pp. 616-626
    • Fitzgibbon, G.M.1    Kafka, H.P.2    Leach, A.J.3    Keon, W.J.4    Hooper, G.D.5    Burton, J.R.6
  • 13
    • 0027534711 scopus 로고
    • Mechanisms of restenosis and redilation within coronary stentsquantitative angiographic assessment
    • P.C. Gordon, C.M. Gibson, D.J. Cohen Mechanisms of restenosis and redilation within coronary stentsquantitative angiographic assessment J Am Coll Cardiol 21 1993 1166 1174
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1166-1174
    • Gordon, P.C.1    Gibson, C.M.2    Cohen, D.J.3
  • 14
    • 0042343776 scopus 로고    scopus 로고
    • Coronary anastomotic devices: Blood-exposed non-intimal surface and coronary wall stress
    • J.S. Schelters, C.J. van Andel, P.V. Pistecky, C. Borst Coronary anastomotic devices: blood-exposed non-intimal surface and coronary wall stress J Thorac Cardiovasc Surg 126 2003 191 199
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 191-199
    • Schelters, J.S.1    Van Andel, C.J.2    Pistecky, P.V.3    Borst, C.4
  • 15
    • 0035005897 scopus 로고    scopus 로고
    • New recommendations from the 1999 American College of Cardiology/American Heart Association acute myocardial infarction guidelines
    • S.A. Spinler, D.E. Hilleman, J.W. Cheng, P.A. Howard, V.F. Mauro, L.M. Lopez New recommendations from the 1999 American College of Cardiology/American Heart Association acute myocardial infarction guidelines Am Pharmacother 35 2001 589 617
    • (2001) Am Pharmacother , vol.35 , pp. 589-617
    • Spinler, S.A.1    Hilleman, D.E.2    Cheng, J.W.3    Howard, P.A.4    Mauro, V.F.5    Lopez, L.M.6
  • 16
    • 0035908781 scopus 로고    scopus 로고
    • Effects of pretreatment with clopidogrel and aspirin followed by long-term therapy in patients undergoing percutaneous coronary intervention: The PCI-CURE study
    • Mehta SR, Yusuf S, Peters RJ, Bertrand ME, Lewis BS, Natarajan MK, et al. Effects of pretreatment with clopidogrel and aspirin followed by long-term therapy in patients undergoing percutaneous coronary intervention: the PCI-CURE study. Lancet. 2001;18:358:527-33.
    • (2001) Lancet , vol.18 , pp. 358
    • Mehta, S.R.1    Yusuf, S.2    Peters, R.J.3    Bertrand, M.E.4    Lewis, B.S.5    Natarajan, M.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.