메뉴 건너뛰기




Volumn 20, Issue SUPPL. 2, 2004, Pages

Continuous glucose monitoring in conditions other than diabetes

Author keywords

Continuous glucose monitoring; Glycogen storage disease; Hypoglycaemia; Insulinoma

Indexed keywords

GLUCOSE; INSULIN;

EID: 11144250405     PISSN: 15207552     EISSN: None     Source Type: Journal    
DOI: 10.1002/dmrr.518     Document Type: Article
Times cited : (28)

References (13)
  • 1
    • 0033062619 scopus 로고    scopus 로고
    • Hypoglycemia is the limiting factor in the management of diabetes
    • Cryer PE. Hypoglycemia is the limiting factor in the management of diabetes. Diabetes Metab Res Rev 1999; 15: 42-46.
    • (1999) Diabetes Metab. Res. Rev. , vol.15 , pp. 42-46
    • Cryer, P.E.1
  • 2
    • 0000869086 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications of insulin-dependent diabetes mellitus
    • The Diabetes Control and Complication Trial (DCCT) Research Group
    • The Diabetes Control and Complication Trial (DCCT) Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications of insulin-dependent diabetes mellitus. New Engl J Med 1993; 329: 997-1036.
    • (1993) New Engl. J. Med. , vol.329 , pp. 997-1036
  • 3
    • 0031032280 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose in type I diabetic patients: Comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions
    • Bolinder J, Hagstrom-Toft E, Ungerstedt U, Arner P. Self-monitoring of blood glucose in type I diabetic patients: comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions. Diabetes Care 1997; 20: 64-70.
    • (1997) Diabetes Care , vol.20 , pp. 64-70
    • Bolinder, J.1    Hagstrom-Toft, E.2    Ungerstedt, U.3    Arner, P.4
  • 4
    • 0032754795 scopus 로고    scopus 로고
    • Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: A pilot study
    • Bode BW, Gross TM, Thornton KR, Mastrototaro JJ. Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study. Diabetes Res Clin Pract 1999; 46: 183-190.
    • (1999) Diabetes Res. Clin. Pract. , vol.46 , pp. 183-190
    • Bode, B.W.1    Gross, T.M.2    Thornton, K.R.3    Mastrototaro, J.J.4
  • 5
    • 0036233922 scopus 로고    scopus 로고
    • Continuous monitoring of blood glucose
    • Robert JJ. Continuous monitoring of blood glucose. Horm Res 2002; 1: (Suppl. 57) 81-84.
    • (2002) Horm. Res. , vol.1 , Issue.SUPPL. 57 , pp. 81-84
    • Robert, J.J.1
  • 6
    • 0242418182 scopus 로고    scopus 로고
    • A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2)
    • Varalli M, Marelli G, Maran A, et al. A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 2). Biosens Bioelectron 2003; 18: 899-905.
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 899-905
    • Varalli, M.1    Marelli, G.2    Maran, A.3
  • 7
    • 0036481429 scopus 로고    scopus 로고
    • Continuous subcutaneous glucose monitoring in diabetic patients: A multicenter analysis
    • Maran A, Crepaldi C, Tiengo A, et al. Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis. Diabetes Care 2002; 25: 347-352.
    • (2002) Diabetes Care , vol.25 , pp. 347-352
    • Maran, A.1    Crepaldi, C.2    Tiengo, A.3
  • 8
    • 11144303738 scopus 로고    scopus 로고
    • Accuracy of continuous subcutaneous glucose monitoring in detecting hypoglycemia in diabetic patients
    • Maran A, Crepaldi C, Ninkovic S, et al. Accuracy of continuous subcutaneous glucose monitoring in detecting hypoglycemia in diabetic patients. Diabetes 2002; Suppl. 1. A499.
    • (2002) Diabetes , Issue.SUPPL. 1
    • Maran, A.1    Crepaldi, C.2    Ninkovic, S.3
  • 10
    • 0035296492 scopus 로고    scopus 로고
    • The molecular basis of type 1 glycogen storage diseases
    • Chou JY. The molecular basis of type 1 glycogen storage diseases. Curr Mol Med 2001; 1: 25-44.
    • (2001) Curr. Mol. Med. , vol.1 , pp. 25-44
    • Chou, J.Y.1
  • 11
    • 0036387478 scopus 로고    scopus 로고
    • Guidelines for management of glycogen storage disease type I - European Study on Glycogen Storage Disease Type I (ESGSD I)
    • Rake JP, Visser G, Labrune P, Leonard JV, Ullrich K, Smit GP. Guidelines for management of glycogen storage disease type I - European Study on Glycogen Storage Disease Type I (ESGSD I). Eur J Pediatr 2002; 1(Suppl. 161): S112-S119.
    • (2002) Eur. J. Pediatr. , vol.1 , Issue.SUPPL. 161
    • Rake, J.P.1    Visser, G.2    Labrune, P.3    Leonard, J.V.4    Ullrich, K.5    Smit, G.P.6
  • 12
    • 0032880067 scopus 로고    scopus 로고
    • Classification of hypoglycemic disorders
    • vi
    • Service FJ. Classification of hypoglycemic disorders. Endocrinol Metab Clin North Am 1999; 28: 501-517, vi.
    • (1999) Endocrinol. Metab. Clin. North Am. , vol.28 , pp. 501-517
    • Service, F.J.1
  • 13


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.