메뉴 건너뛰기




Volumn 52, Issue 10 SPEC. ISS., 2004, Pages 617-621

Comparison of five usual techniques for detection of methicillin-resistant Staphylococcus aureus;Détection de la résistance à l'oxacilline chez Staphylococcus aureus: Comparaison de cinq techniques utilisables en routine

Author keywords

Cefoxitine; Cefoxtin; thicillino sistance; Methicillin resistant; Routine; Staphylococcus aureus; Techniques de d tection; Usual methods of detection

Indexed keywords

CEFOXITIN; OXACILLIN;

EID: 11144234025     PISSN: 03698114     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.patbio.2004.09.005     Document Type: Article
Times cited : (2)

References (9)
  • 2
    • 2442575077 scopus 로고    scopus 로고
    • Staphylococcus aureus, Ŕsistance aux antibiotiques, revue de la litt́rature
    • A. Ben Hassaen, and B. Redjeb Staphylococcus aureus, Ŕsistance aux antibiotiques, revue de la litt́rature Feuillet de biologie 38 214 1997 23 29
    • (1997) Feuillet de Biologie , vol.38 , Issue.214 , pp. 23-29
    • Ben Hassaen, A.1    Redjeb, B.2
  • 3
    • 84860062664 scopus 로고    scopus 로고
    • Comit́ de l'Antibiogramme de la Socít́ fraņaise de microbiologie Communiqú 2002.
    • Comit́ de l'Antibiogramme de la Socít́ fraņaise de microbiologie Communiqú 2002.
  • 4
    • 0035045414 scopus 로고    scopus 로고
    • Staphylococcus:aureus: New detection of intrinsic resistance using the diffusion method
    • C. Mougeot, J. Guillaumat-Tailliet, and J.M. Libert Staphylococcus: aureus: new detection of intrinsic resistance using the diffusion method Pathol. Biol. (Paris) 49 3 2001 199 204
    • (2001) Pathol. Biol. (Paris) , vol.49 , Issue.3 , pp. 199-204
    • Mougeot, C.1    Guillaumat-Tailliet, J.2    Libert, J.M.3
  • 5
    • 0036701939 scopus 로고    scopus 로고
    • Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus:aureus (MRSA): A disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-screen latex agglutination test
    • A. Felten, B. Gandry, P.H. Lagrange, and I. Casin Evaluation of three techniques for detection of low-level methicillin-resistant Staphylococcus: aureus (MRSA): a disk diffusion method with cefoxitin and moxalactam, the Vitek 2 system, and the MRSA-screen latex agglutination test J. Clin. Microbiol. 40 8 August 2002 2766 2771
    • (2002) J. Clin. Microbiol. , vol.40 , Issue.8 , pp. 2766-2771
    • Felten, A.1    Gandry, B.2    Lagrange, P.H.3    Casin, I.4
  • 6
    • 0034125065 scopus 로고    scopus 로고
    • Evaluation of three rapid methods for detection of methicillin resistance in Staphylococcus:aureus
    • L. Louie, S.O. Matsumura, E. Choi, M. Louie, and A.E. Simor Evaluation of three rapid methods for detection of methicillin resistance in Staphylococcus:aureus J. Clin. Microbiol. 38 6 2000 2170 2173
    • (2000) J. Clin. Microbiol. , vol.38 , Issue.6 , pp. 2170-2173
    • Louie, L.1    Matsumura, S.O.2    Choi, E.3    Louie, M.4    Simor, A.E.5
  • 7
    • 84860060008 scopus 로고    scopus 로고
    • Staphylococcus:aureus ŕsistant ̀ la ḿthicilline(SARM) /S.:aureus sensible ̀ la ḿthicilline (SASM)::non expression ou perte spontańe du g̀ne de ŕsistance (ŕsuḿ de communication RICAI 2000)
    • P.Y. Donnio Staphylococcus:aureus ŕsistant ̀ la ḿthicilline(SARM)/S.:aureus sensible ̀ la ḿthicilline (SASM)::non expression ou perte spontańe du g̀ne de ŕsistance (ŕsuḿ de communication RICAI 2000) La lettre de l'infectiologue Jan/Fev 16 1-2 2001 38 39
    • (2001) La Lettre de l'Infectiologue Jan/Fev , vol.16 , Issue.12 , pp. 38-39
    • Donnio, P.Y.1
  • 9
    • 84860062896 scopus 로고    scopus 로고
    • Comit́ de l'antibiogramme de la Socít́ fraņaise de microbiologie Communiqú 2004.
    • Comit́ de l'antibiogramme de la Socít́ fraņaise de microbiologie Communiqú 2004.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.