메뉴 건너뛰기




Volumn 49, Issue 23, 2004, Pages 5333-5345

The impact of inter-fraction dose variations on biological equivalent dose (BED): The concept of equivalent constant dose

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; CELLS; MATHEMATICAL MODELS; MONTE CARLO METHODS; PROBABILITY DENSITY FUNCTION; RADIOTHERAPY; TISSUE;

EID: 11044233902     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/49/23/010     Document Type: Article
Times cited : (10)

References (22)
  • 1
    • 0037037771 scopus 로고    scopus 로고
    • A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error
    • Beckham W A et al 2002 A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error Phys. Med. Biol. 47 3465
    • (2002) Phys. Med. Biol. , vol.47 , pp. 3465
    • Beckham, W.A.1
  • 2
    • 0033237778 scopus 로고    scopus 로고
    • Set-up error & organ motion uncertainty: A review Australas
    • Booth J T and Zavgorodni S F 1999 Set-up error & organ motion uncertainty: a review Australas. Phys. Eng. Sci. Med. 22 29-47
    • (1999) Phys. Eng. Sci. Med. , vol.22 , pp. 29-47
    • Booth, J.T.1    Zavgorodni, S.F.2
  • 3
    • 0034921660 scopus 로고    scopus 로고
    • The effects of radiotherapy treatment uncertainties on the delivered dose distribution and tumour control probability
    • Booth J T and Zavgorodni S F 2001 The effects of radiotherapy treatment uncertainties on the delivered dose distribution and tumour control probability Australas. Phys. Eng. Sci. Med. 24 71-8
    • (2001) Australas. Phys. Eng. Sci. Med. , vol.24 , pp. 71-78
    • Booth, J.T.1    Zavgorodni, S.F.2
  • 4
    • 0010990601 scopus 로고
    • Dosimetric precision requirements in radiation therapy
    • Brahme A 1984 Dosimetric precision requirements in radiation therapy Acta Radiol. Oncol. 23 379-91
    • (1984) Acta Radiol. Oncol. , vol.23 , pp. 379-391
    • Brahme, A.1
  • 5
    • 0002387112 scopus 로고    scopus 로고
    • Dosimetric precision requirements and quantities for characterizing the response of tumours and normal tissues
    • IAEA TECDOC Series No. 896. Radiation Dose in Radiotherapy from Prescription to Delivery (Vienna, Austria: International Atomic Energy Agency)
    • Brahme A 1996 Dosimetric precision requirements and quantities for characterizing the response of tumours and normal tissues IAEA TECDOC Series No. 896. Radiation Dose in Radiotherapy from Prescription to Delivery (Vienna, Austria: International Atomic Energy Agency) pp 49-65
    • (1996) , pp. 49-65
    • Brahme, A.1
  • 6
    • 0141838859 scopus 로고    scopus 로고
    • The impact of geometric uncertainty on hypofractionated external beam radiation therapy of prostate cancer
    • Craig T et al 2003 The impact of geometric uncertainty on hypofractionated external beam radiation therapy of prostate cancer Int. J. Radiat. Oncol. Biol. Phys. 57 833-42
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.57 , pp. 833-842
    • Craig, T.1
  • 7
    • 0033965789 scopus 로고    scopus 로고
    • Viability of the EUD and TCP concepts as reliable dose indicators
    • Ebert M A 2000 Viability of the EUD and TCP concepts as reliable dose indicators Phys. Med. Biol. 45 441
    • (2000) Phys. Med. Biol. , vol.45 , pp. 441
    • Ebert, M.A.1
  • 8
    • 0038724753 scopus 로고    scopus 로고
    • What hypofractionated protocols should be tested for prostate cancer?
    • Fowler J F et al 2003 What hypofractionated protocols should be tested for prostate cancer? Int. J. Radiat. Oncol. Biol. Phys. 56 1093-104
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.56 , pp. 1093-1104
    • Fowler, J.F.1
  • 9
    • 0033237777 scopus 로고    scopus 로고
    • A method to predict the effect of organ motion and set-up variations on treatment plans
    • Keall P J et al 1999 A method to predict the effect of organ motion and set-up variations on treatment plans Australas. Phys. Eng. Sci. Med. 22 48-52
    • (1999) Australas. Phys. Eng. Sci. Med. , vol.22 , pp. 48-52
    • Keall, P.J.1
  • 10
    • 0031058446 scopus 로고    scopus 로고
    • A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy
    • Killoran J H et al 1997 A numerical simulation of organ motion and daily setup uncertainties: implications for radiation therapy Int. J. Radiat. Oncol. Biol. Phys. 37 213-21
    • (1997) Int. J. Radiat. Oncol. Biol. Phys. , vol.37 , pp. 213-221
    • Killoran, J.H.1
  • 11
    • 0035450897 scopus 로고    scopus 로고
    • A simple analytic derivation suggests that prostate cancer [alpha]/[beta] ratio is low
    • King C R and Fowler J F 2001 A simple analytic derivation suggests that prostate cancer [alpha]/[beta] ratio is low Int. J. Radiat. Oncol. Biol. Phys. 51 213-4
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.51 , pp. 213-214
    • King, C.R.1    Fowler, J.F.2
  • 13
    • 0023132335 scopus 로고
    • Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation
    • Leong J 1987 Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation Phys. Med. Biol. 32 327
    • (1987) Phys. Med. Biol. , vol.32 , pp. 327
    • Leong, J.1
  • 14
    • 0033867216 scopus 로고    scopus 로고
    • Inverse planning incorporating organ motion
    • Li J G and Xing L 2000 Inverse planning incorporating organ motion Med. Phys. 27 1573-8
    • (2000) Med. Phys. , vol.27 , pp. 1573-1578
    • Li, J.G.1    Xing, L.2
  • 15
    • 0032718383 scopus 로고    scopus 로고
    • Quantization of setup uncertainties in 3-D dose calculations
    • Lujan A E et al 1999 Quantization of setup uncertainties in 3-D dose calculations Med. Phys. 26 2397-402
    • (1999) Med. Phys. , vol.26 , pp. 2397-2402
    • Lujan, A.E.1
  • 16
    • 0029975378 scopus 로고    scopus 로고
    • A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans
    • Mageras G S et al 1996 A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans Int. J. Radiat. Oncol. Biol. Phys. 35 333-42
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 333-342
    • Mageras, G.S.1
  • 17
    • 0031037018 scopus 로고    scopus 로고
    • Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    • Niemierko A 1997 Reporting and analyzing dose distributions: a concept of equivalent uniform dose Med. Phys. 24 103-10
    • (1997) Med. Phys. , vol.24 , pp. 103-110
    • Niemierko, A.1
  • 18
    • 0030586081 scopus 로고    scopus 로고
    • Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer
    • Rudat V et al 1996 Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer Int. J. Radiat. Oncol. Biol. Phys. 35 1027-34
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 1027-1034
    • Rudat, V.1
  • 19
    • 0345257799 scopus 로고    scopus 로고
    • Biologic and physical fractionation effects of random geometric errors
    • van Herk M et al 2003 Biologic and physical fractionation effects of random geometric errors Int. J. Radiat. Oncol. Biol. Phys. 57 1460-71
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.57 , pp. 1460-1471
    • van Herk, M.1
  • 20
    • 0028138655 scopus 로고
    • A proof that uniform dose gives the greatest TCP for fixed integral dose in the planning target volume
    • Webb S et al 1994 A proof that uniform dose gives the greatest TCP for fixed integral dose in the planning target volume Phys. Med. Biol. 39 2091
    • (1994) Phys. Med. Biol. , vol.39 , pp. 2091
    • Webb, S.1
  • 21
    • 0035045155 scopus 로고    scopus 로고
    • Organ/patient geometric variation in external beam radiotherapy and its effects
    • Yan D and Lockman D 2001 Organ/patient geometric variation in external beam radiotherapy and its effects Med. Phys. 28 593-602
    • (2001) Med. Phys. , vol.28 , pp. 593-602
    • Yan, D.1    Lockman, D.2
  • 22
    • 0034004037 scopus 로고    scopus 로고
    • Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy
    • Zavgorodni S F 2000 Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy Med. Phys. 27 685-90
    • (2000) Med. Phys. , vol.27 , pp. 685-690
    • Zavgorodni, S.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.