-
1
-
-
0001398689
-
Conversion of hydrogenic materials to hydrogen for isotopic analysis
-
Bigeleisen, J., Perlman, M. L. and Prosser, H. C. (1952) Conversion of hydrogenic materials to hydrogen for isotopic analysis. Anal. Chem. 24, 1356-1357.
-
(1952)
Anal. Chem.
, vol.24
, pp. 1356-1357
-
-
Bigeleisen, J.1
Perlman, M.L.2
Prosser, H.C.3
-
2
-
-
0020125416
-
Reduction of water with zinc for hydrogen isotope analysis
-
Coleman, M. L., Shepherd, T. J., Durnham, J. J., Rouse, J. E. and Moore, G. R. (1982) Reduction of water with zinc for hydrogen isotope analysis. Anal. Chem. 54, 993-995.
-
(1982)
Anal. Chem.
, vol.54
, pp. 993-995
-
-
Coleman, M.L.1
Shepherd, T.J.2
Durnham, J.J.3
Rouse, J.E.4
Moore, G.R.5
-
3
-
-
0034894743
-
Hydrogen isotope analysis of natural abundance and deuterium-enriched waters by reduction over chromium online to a dunamic dual inlet isotope-ratio mass spectrometer
-
Donelly, T., Waldron, S., Tait, A., Dougans, J. and Bearhop, S. (2001) Hydrogen isotope analysis of natural abundance and deuterium-enriched waters by reduction over chromium online to a dunamic dual inlet isotope-ratio mass spectrometer. Rapid Commun. Mass Spec. 15 1297-1303.
-
(2001)
Rapid Commun. Mass Spec.
, vol.15
, pp. 1297-1303
-
-
Donelly, T.1
Waldron, S.2
Tait, A.3
Dougans, J.4
Bearhop, S.5
-
4
-
-
85039464145
-
The H/Device, a novel peripheral for measurement of D/H from microliter samples of water and organic molecules
-
Finnigan MAT Application Flash Report No. G27
-
Finnigan MAT (1997) The H/Device, a novel peripheral for measurement of D/H from microliter samples of water and organic molecules. Application Flash Report No. G27.
-
(1997)
-
-
-
5
-
-
0022393758
-
Sample preparation for hydrogen isotope analysis by mass spectrometry
-
Florkowski, T. (1985) Sample preparation for hydrogen isotope analysis by mass spectrometry. Int. J. Appl. Radiat. Isot. 36, 991-992.
-
(1985)
Int. J. Appl. Radiat. Isot.
, vol.36
, pp. 991-992
-
-
Florkowski, T.1
-
6
-
-
0030394874
-
Sample preparation device for quantitative hydrogen isotope analysis using chromium metal
-
Gehre, M., Hoefling, R., Kowski, P. and Strauch, G. (1996) Sample preparation device for quantitative hydrogen isotope analysis using chromium metal. Anal. Chem. 68, 4414-4417.
-
(1996)
Anal. Chem.
, vol.68
, pp. 4414-4417
-
-
Gehre, M.1
Hoefling, R.2
Kowski, P.3
Strauch, G.4
-
7
-
-
0017873831
-
Standards for stable isotope measurements in natural compounds
-
Gonfiantini, R. (1978) Standards for stable isotope measurements in natural compounds. Nature 271, 534-536.
-
(1978)
Nature
, vol.271
, pp. 534-536
-
-
Gonfiantini, R.1
-
8
-
-
0007450276
-
2 for hydrogen isotopic analysis of water
-
Indiana University, Biogeochemical Laboratories, internal report
-
2 for hydrogen isotopic analysis of water. Indiana University, Biogeochemical Laboratories, internal report.
-
(1988)
-
-
Hayes, J.M.1
Johnson, M.W.2
-
9
-
-
0002426085
-
2-water equilibration method: A special implication to brines
-
2-water equilibration method: A special implication to brines. Chem. Geol. 72, 89-94.
-
(1988)
Chem. Geol.
, vol.72
, pp. 89-94
-
-
Horita, J.1
-
10
-
-
0027386290
-
The activity-composition relationship of oxygen and hydrogen isotopes in aqueous salt solutions: I. Vapor-liquid equilibration of single salt solutions from 50 to 100°C
-
Horita, J., Wesolowski, D. J. and Cole, D. R. (1993) The activity-composition relationship of oxygen and hydrogen isotopes in aqueous salt solutions: I. Vapor-liquid equilibration of single salt solutions from 50 to 100°C. Geochim. Cosmochim. Acta 57, 2797-2817.
-
(1993)
Geochim. Cosmochim. Acta
, vol.57
, pp. 2797-2817
-
-
Horita, J.1
Wesolowski, D.J.2
Cole, D.R.3
-
11
-
-
21844515683
-
Temperature dependence of fractionation of hydrogen isotopes in aqueous sodium chloride solutions
-
Kakiuchi, M. (1994) Temperature dependence of fractionation of hydrogen isotopes in aqueous sodium chloride solutions. J. Solution Chem. 23, 1073-1087.
-
(1994)
J. Solution Chem.
, vol.23
, pp. 1073-1087
-
-
Kakiuchi, M.1
-
12
-
-
0022169909
-
Multisample conversion of water to hydrogen by zinc for stable isotope determination
-
Kendall, C. and Coplen, T. B. (1985) Multisample conversion of water to hydrogen by zinc for stable isotope determination. Anal. Chem. 57, 1437-1440.
-
(1985)
Anal. Chem.
, vol.57
, pp. 1437-1440
-
-
Kendall, C.1
Coplen, T.B.2
-
13
-
-
0035417210
-
On-line high-precision stable hydrogen isotopic analyses on nanoliter water samples
-
Morrison, J., Brockwell, T., Merren, T., Fourel, F. and Philips, A. M. (2001) On-line high-precision stable hydrogen isotopic analyses on nanoliter water samples. Anal. Chem. 73, 3570-3575.
-
(2001)
Anal. Chem.
, vol.73
, pp. 3570-3575
-
-
Morrison, J.1
Brockwell, T.2
Merren, T.3
Fourel, F.4
Philips, A.M.5
-
14
-
-
0035207297
-
Improving hydrogen isotope ratio measurements for on-line chromium reduction systems
-
Nelson, S. T. and Dettman, D. (2001) Improving hydrogen isotope ratio measurements for on-line chromium reduction systems. Rapid Commun. Mass Spec. 15, 2301-2306.
-
(2001)
Rapid Commun. Mass Spec.
, vol.15
, pp. 2301-2306
-
-
Nelson, S.T.1
Dettman, D.2
-
15
-
-
85039470144
-
Reactivity of zinc for hydrogen isotope analysis
-
Tech. Rep. ISEI B14, (in Japanese)
-
Noto, M. and Kusakabe, M. (1995) Reactivity of zinc for hydrogen isotope analysis. Tech. Rep. ISEI B14, 1-12 (in Japanese).
-
(1995)
, pp. 1-12
-
-
Noto, M.1
Kusakabe, M.2
-
16
-
-
0030434817
-
2O equilibration method for D/H measurement of water
-
2O equilibration method for D/H measurement of water. Geochem. J. 30, 373-377.
-
(1996)
Geochem. J.
, vol.30
, pp. 373-377
-
-
Ohba, T.1
Hirabayashi, J.2
-
17
-
-
85008013459
-
Isotope exchange technique for preparation of hydrogen gas in mass spectrometric D/H analysis of natural waters
-
Ohsumi, T. and Fujino, H. (1986) Isotope exchange technique for preparation of hydrogen gas in mass spectrometric D/H analysis of natural waters. Anal. Sci. 2, 489-490.
-
(1986)
Anal. Sci.
, vol.2
, pp. 489-490
-
-
Ohsumi, T.1
Fujino, H.2
-
18
-
-
0003612524
-
Importance of clean metallic zinc for hydrogen isotope analysis
-
Tanweer, A. (1990) Importance of clean metallic zinc for hydrogen isotope analysis. Anal. Chem. 62, 2158-2160.
-
(1990)
Anal. Chem.
, vol.62
, pp. 2158-2160
-
-
Tanweer, A.1
-
19
-
-
0002434285
-
Reduction of mocro liter amounts of water with manganese for D/H isotopic ratio measurements by mass spectromery
-
Tanweer, A. and Han, L. F. (1996) Reduction of mocro liter amounts of water with manganese for D/H isotopic ratio measurements by mass spectromery. Isotopes Environ. Health Stud. 32, 97-103.
-
(1996)
Isotopes Environ. Health Stud.
, vol.32
, pp. 97-103
-
-
Tanweer, A.1
Han, L.F.2
-
20
-
-
0032459343
-
An automated system for hydrogen isotope analysis of water
-
Vaughn, V. H., White, J. W. C., Delmotte, M., Troiler, M., Cattani, O. and Stievenard, M. (1998) An automated system for hydrogen isotope analysis of water. Chem. Geol. 152, 309-319.
-
(1998)
Chem. Geol.
, vol.152
, pp. 309-319
-
-
Vaughn, V.H.1
White, J.W.C.2
Delmotte, M.3
Troiler, M.4
Cattani, O.5
Stievenard, M.6
-
21
-
-
0027387273
-
A simple and inexpensive method of hydrogen isotope and water analyses of minerals and rocks based on zinc reagent
-
Vennemann, T. W. and O'Neil, J. R. (1993) A simple and inexpensive method of hydrogen isotope and water analyses of minerals and rocks based on zinc reagent. Chem. Geol. 103, 227-234.
-
(1993)
Chem. Geol.
, vol.103
, pp. 227-234
-
-
Vennemann, T.W.1
O'Neil, J.R.2
|