메뉴 건너뛰기




Volumn 21, Issue 4, 2003, Pages 178-182

Intercomparison of Dose Distribution between Gamma Knife and C-arm-mounted Linac

Author keywords

C arm linac; Dose distribution; Gamma Knife; Radiosurgery

Indexed keywords

ARTICLE; BRAIN TUMOR; DEVICE; GAMMA KNIFE; GAMMA KNIFE RADIOSURGERY; HISTOGRAM; INTERMETHOD COMPARISON; LINEAR ACCELERATOR; LOW ENERGY RADIATION; RADIATION BEAM; RADIATION DOSE DISTRIBUTION; ROTATION;

EID: 10744229849     PISSN: 02882043     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (14)
  • 1
    • 76949138594 scopus 로고
    • The stereotactic method and radiosurgery of the brain
    • Leksell L. The stereotactic method and radiosurgery of the brain. Acta Chir Scand, 102: 316-319, 1951.
    • (1951) Acta Chir Scand , vol.102 , pp. 316-319
    • Leksell, L.1
  • 3
    • 0021994663 scopus 로고
    • External stereotactic irradiation by linear accelerator
    • Colombo F, Benedetti A, Pozza F, et al. External stereotactic irradiation by linear accelerator. Neurosurgery, 16: 154-159, 1985.
    • (1985) Neurosurgery , vol.16 , pp. 154-159
    • Colombo, F.1    Benedetti, A.2    Pozza, F.3
  • 4
    • 84940125866 scopus 로고
    • Stereotactic radiosurgery utilizing a linear accelerator
    • Colombo F, Benedetti A, Pozza F, et al. Stereotactic radiosurgery utilizing a linear accelerator. Appl Neurophysiol, 48: 133-145, 1985.
    • (1985) Appl Neurophysiol , vol.48 , pp. 133-145
    • Colombo, F.1    Benedetti, A.2    Pozza, F.3
  • 5
    • 0023875610 scopus 로고
    • A system for stereotactic radiosurgery with a linear accelerator
    • Lutz W, Winston KR, Maleki N. A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys, 14: 373-381, 1988.
    • (1988) Int J Radiat Oncol Biol Phys , vol.14 , pp. 373-381
    • Lutz, W.1    Winston, K.R.2    Maleki, N.3
  • 7
    • 0032863004 scopus 로고    scopus 로고
    • Dosimetric comparison of three photon radiosurgery techniques for an elongated ellipsoid target
    • Yu C, Luxton G, Jozsef G, et al. Dosimetric comparison of three photon radiosurgery techniques for an elongated ellipsoid target. Int J Radiat Oncol Biol Phys, 45: 817-826, 1999.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 817-826
    • Yu, C.1    Luxton, G.2    Jozsef, G.3
  • 8
    • 0344751160 scopus 로고    scopus 로고
    • C-arm multi-axis rotation stereotactic linac radiosurgery system
    • Tamaki T, Ehara K, Fujita K. C-arm multi-axis rotation stereotactic linac radiosurgery system. J Radiosurgery, 3: 21-27, 2000.
    • (2000) J Radiosurgery , vol.3 , pp. 21-27
    • Tamaki, T.1    Ehara, K.2    Fujita, K.3
  • 9
    • 0005173481 scopus 로고    scopus 로고
    • Dynamic conical conformal radiotherapy using a C-arm-mounted accelerator
    • Nakagawa K, Aoki Y, Ohtomo K. Dynamic conical conformal radiotherapy using a C-arm-mounted accelerator. Int J Radiat Oncol Biol Phys, 48 (Suppl): 220, 2000.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , Issue.SUPPL. , pp. 220
    • Nakagawa, K.1    Aoki, Y.2    Ohtomo, K.3
  • 10
    • 0037402531 scopus 로고    scopus 로고
    • Dynamic conical conformal radiotherapy using a C-arm mounted accelerator: Dose distribution and clinical application
    • Nakagawa K, Aoki Y, Tago M, Ohtomo K. Dynamic conical conformal radiotherapy using a C-arm mounted accelerator: dose distribution and clinical application. Int J Radiat Oncol Biol Phys, 56: 287-295, 2003.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 287-295
    • Nakagawa, K.1    Aoki, Y.2    Tago, M.3    Ohtomo, K.4
  • 11
    • 0034653771 scopus 로고    scopus 로고
    • Image localization for frameless stereotactic radiotherapy
    • Meeks SL, Bova FJ, Wagner TH, et al. Image localization for frameless stereotactic radiotherapy. Int J Radiat Oncol Biol Phys, 46: 1291-1299, 2000.
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 1291-1299
    • Meeks, S.L.1    Bova, F.J.2    Wagner, T.H.3
  • 12
    • 0032692441 scopus 로고    scopus 로고
    • Verification of the alignment of a therapeutic radiation beam relative to its patient positioner
    • Barkhof J, Schut G, Flanz JB, et al. Verification of the alignment of a therapeutic radiation beam relative to its patient positioner. Med Phys, 26: 2429-2437, 1999.
    • (1999) Med Phys , vol.26 , pp. 2429-2437
    • Barkhof, J.1    Schut, G.2    Flanz, J.B.3
  • 13
    • 0025312455 scopus 로고
    • Physics of Gamma Knife approach on convergent beams in stereotactic radiosurgery
    • Wu A, Lindner G, Maitz AH, et al. Physics of Gamma Knife approach on convergent beams in stereotactic radiosurgery. Int J Radiat Oncol Biol Phys, 18: 941-949, 1990.
    • (1990) Int J Radiat Oncol Biol Phys , vol.18 , pp. 941-949
    • Wu, A.1    Lindner, G.2    Maitz, A.H.3
  • 14
    • 0024492354 scopus 로고
    • Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source Gamma Knife
    • Lunsford LD, Flickinger J, Lindner G, et al. Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source Gamma Knife. Neurosurgery, 24: 151-159, 1989.
    • (1989) Neurosurgery , vol.24 , pp. 151-159
    • Lunsford, L.D.1    Flickinger, J.2    Lindner, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.