메뉴 건너뛰기




Volumn 27, Issue 8, 2003, Pages 706-713

Commissural dehiscence and pannus formation of porcine heart valve bioprostheses

Author keywords

Calcification; Commissural dehiscence; Pannus; Porcine heart valve bioprosthesis; Valve regurgitation

Indexed keywords

ANTI-COAGULATION; AORTIC POSITION; BIOPROSTHESES; COMMISSURAL DEHISCENCE; PANNUS; PORCINE HEART VALVE BIOPROSTHESIS; VALVE REGURGITATION;

EID: 10744220232     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.2003.06963.x     Document Type: Article
Times cited : (4)

References (15)
  • 1
    • 0019670403 scopus 로고
    • Structure and classification of cuspal tears and perforations in porcine bioprosthetic cardiac valves implanted in patients
    • Ishihara T, Ferrans VJ, Boyce SW, Roberts WC. Structure and classification of cuspal tears and perforations in porcine bioprosthetic cardiac valves implanted in patients. Am J Cardiol 1981;48:665-78.
    • (1981) Am J Cardiol , vol.48 , pp. 665-678
    • Ishihara, T.1    Ferrans, V.J.2    Boyce, S.W.3    Roberts, W.C.4
  • 2
    • 0032713991 scopus 로고    scopus 로고
    • Echocardiographic and pathologic features of explanted Hancock and Carpentier-Edwards bioprosthetic valves in the mitral position
    • Naqvi TZ, Siegel RJ, Buchbinder NA, Miroshnik S, Saedi G, Trento A, Fishbein MC. Echocardiographic and pathologic features of explanted Hancock and Carpentier-Edwards bioprosthetic valves in the mitral position. Am J Cardiol 1999;84:1422-7.
    • (1999) Am J Cardiol , vol.84 , pp. 1422-1427
    • Naqvi, T.Z.1    Siegel, R.J.2    Buchbinder, N.A.3    Miroshnik, S.4    Saedi, G.5    Trento, A.6    Fishbein, M.C.7
  • 4
    • 0023639782 scopus 로고
    • Chemically determined content of explanted porcine aortic valve bioprostheses: Correlation with radiographic assessment of calcification and clinical data
    • Schoen FJ, Kujovich JL, Webb CL, Levy RJ. Chemically determined content of explanted porcine aortic valve bioprostheses: correlation with radiographic assessment of calcification and clinical data. Circulation 1987;76:1061-6.
    • (1987) Circulation , vol.76 , pp. 1061-1066
    • Schoen, F.J.1    Kujovich, J.L.2    Webb, C.L.3    Levy, R.J.4
  • 5
    • 0019942833 scopus 로고
    • The clinical life history of explanted prosthetic heart valves
    • Marbarger JP Jr., Clark RE. The clinical life history of explanted prosthetic heart valves. Ann Thorac Surg 1982;34:22-33.
    • (1982) Ann Thorac Surg , vol.34 , pp. 22-33
    • Marbarger J.P., Jr.1    Clark, R.E.2
  • 6
    • 0024655968 scopus 로고
    • Bioprosthetic valvular dysfunction in mitral position. Three cases of commissural detachment
    • in Japanese
    • Aoyagi S, Tanaka K, Nishi K, Hara H, Kosuga K, Oishi K. Bioprosthetic valvular dysfunction in mitral position. Three cases of commissural detachment. Rinsho Kyobu Geka 1989;9:195-8 (in Japanese).
    • (1989) Rinsho Kyobu Geka , vol.9 , pp. 195-198
    • Aoyagi, S.1    Tanaka, K.2    Nishi, K.3    Hara, H.4    Kosuga, K.5    Oishi, K.6
  • 7
    • 0028130696 scopus 로고
    • Rapidly deteriorated failure of Carpentier-Edwards porcine bioprosthesis caused by three detached commissures: Report of a case
    • Terada Y, Wanibuchi Y. Rapidly deteriorated failure of Carpentier-Edwards porcine bioprosthesis caused by three detached commissures: report of a case. Surg Today Jpn J Surg 1994;24:823-5.
    • (1994) Surg Today Jpn J Surg , vol.24 , pp. 823-825
    • Terada, Y.1    Wanibuchi, Y.2
  • 8
    • 0033629926 scopus 로고    scopus 로고
    • A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position
    • in Japanese
    • Hayashi K, Nakano H, Sakamoto Y, Okamoto H. A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position. Kyobugeka 2000;53:79-82 (in Japanese).
    • (2000) Kyobugeka , vol.53 , pp. 79-82
    • Hayashi, K.1    Nakano, H.2    Sakamoto, Y.3    Okamoto, H.4
  • 11
    • 0017755058 scopus 로고
    • The glutaraldehyde-treated heterograft valve. Some engineering observations
    • Thomson FJ, Barratt-Boyes BG. The glutaraldehyde-treated heterograft valve. Some engineering observations. J Thorac Cardiovsc Surg 1977;74:317-21.
    • (1977) J Thorac Cardiovsc Surg , vol.74 , pp. 317-321
    • Thomson, F.J.1    Barratt-Boyes, B.G.2
  • 13
    • 0033056910 scopus 로고    scopus 로고
    • Morphologic findings in explanted Hancock II porcine bioprostheses
    • Butany J, Yu W, Silver MD, David TE. Morphologic findings in explanted Hancock II porcine bioprostheses. J Heart Valve Dis 1999;8:4-15.
    • (1999) J Heart Valve Dis , vol.8 , pp. 4-15
    • Butany, J.1    Yu, W.2    Silver, M.D.3    David, T.E.4
  • 14
    • 0025453768 scopus 로고
    • A case of bioprosthetic mitral valvular dysfunction due to pannus-formation
    • in Japanese
    • Takagi Y, Terada Y, Shimoyama Y, Ino T, Wanibuchi Y, Furuta S. A case of bioprosthetic mitral valvular dysfunction due to pannus-formation. Kyobageka 1990;43:569-72 (in Japanese).
    • (1990) Kyobageka , vol.43 , pp. 569-572
    • Takagi, Y.1    Terada, Y.2    Shimoyama, Y.3    Ino, T.4    Wanibuchi, Y.5    Furuta, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.