메뉴 건너뛰기




Volumn 32, Issue 12, 2004, Pages 2545-2546

Bispectral Index monitoring for assessment of level of consciousness in brain-injured patients: The journey continues

Author keywords

Bispectral Index; Brain injury; Encephalopathy; Intensive care unit; Level of consciousness; Monitoring; Sedation

Indexed keywords

BISPECTRAL INDEX; BRAIN INJURY; CONSCIOUSNESS; CRITICAL ILLNESS; EDITORIAL; HUMAN; INTERMETHOD COMPARISON; PRIORITY JOURNAL; RATING SCALE; RELIABILITY; SEDATION;

EID: 10644284768     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000148084.60943.50     Document Type: Editorial
Times cited : (6)

References (20)
  • 1
    • 0021685812 scopus 로고
    • Electroencephalography in diffuse encephalopathies
    • Markand ON: Electroencephalography in diffuse encephalopathies. J Clin Neurophysiol 1984; 1:357-407
    • (1984) J Clin Neurophysiol , vol.1 , pp. 357-407
    • Markand, O.N.1
  • 2
    • 0031648072 scopus 로고    scopus 로고
    • Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients
    • De Deyne C, Struys M, Decruyenaere J, et al: Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients. Intensive Care Med 1998; 24:1294-1298
    • (1998) Intensive Care Med , vol.24 , pp. 1294-1298
    • De Deyne, C.1    Struys, M.2    Decruyenaere, J.3
  • 3
    • 0036309803 scopus 로고    scopus 로고
    • How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study
    • Nasraway SA Jr, Wu EC, Kelleher RM, et al: How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study. Crit Care Med 2002; 30:1483-1487
    • (2002) Crit Care Med , vol.30 , pp. 1483-1487
    • Nasraway Jr., S.A.1    Wu, E.C.2    Kelleher, R.M.3
  • 4
    • 10644289375 scopus 로고    scopus 로고
    • Bispectral Index monitoring correlates with sedation scales in brain-injured patients
    • Deogaonkar A, Gupta R, DeGeorgia M, et al: Bispectral Index monitoring correlates with sedation scales in brain-injured patients. Crit Care Med 2004; 32:2403-2406
    • (2004) Crit Care Med , vol.32 , pp. 2403-2406
    • Deogaonkar, A.1    Gupta, R.2    DeGeorgia, M.3
  • 5
    • 0002501296 scopus 로고    scopus 로고
    • Bilateral versus unilateral EEG monitoring with the Bispectral Index: A comparison among adult ICU patients
    • Riker R, Fraser G, Wilkins M, et al: Bilateral versus unilateral EEG monitoring with the Bispectral Index: A comparison among adult ICU patients. Chest 2000; 118:95S
    • (2000) Chest , vol.118
    • Riker, R.1    Fraser, G.2    Wilkins, M.3
  • 6
    • 0001743455 scopus 로고    scopus 로고
    • Pitfalls of monitoring sedation in the ICU with the Bispectral Index
    • O'Connor M, Kress J, Pohlman A, et al: Pitfalls of monitoring sedation in the ICU with the Bispectral Index. Anesthesiology 1998; 89:A461
    • (1998) Anesthesiology , vol.89
    • O'Connor, M.1    Kress, J.2    Pohlman, A.3
  • 7
    • 10644292994 scopus 로고    scopus 로고
    • BIS monitoring as neurological outcome predictor in severely brain damaged unconscious patients
    • Fabregas N, Valero R, Gambus P, et al: BIS monitoring as neurological outcome predictor in severely brain damaged unconscious patients. J Neurosurg Anesthesiol 2001; 13:A74
    • (2001) J Neurosurg Anesthesiol , vol.13
    • Fabregas, N.1    Valero, R.2    Gambus, P.3
  • 8
    • 0028318251 scopus 로고
    • Beyond the Ramsay scale: Need for a validated measure of sedating drug efficacy in the intensive care unit
    • Hansen-Flaschen J, Cowen J, Polomano RC: Beyond the Ramsay scale: Need for a validated measure of sedating drug efficacy in the intensive care unit. Crit Care Med 1994; 22:732-733
    • (1994) Crit Care Med , vol.22 , pp. 732-733
    • Hansen-Flaschen, J.1    Cowen, J.2    Polomano, R.C.3
  • 9
    • 0038142852 scopus 로고    scopus 로고
    • Monitoring sedation status over time in ICU patients: Reliability and validity of the Richmond Agitation- Sedation Scale (RASS)
    • Ely EW, Truman B, Shintani A, et al: Monitoring sedation status over time in ICU patients: Reliability and validity of the Richmond Agitation- Sedation Scale (RASS). JAMA 2003; 289:2983-2991
    • (2003) JAMA , vol.289 , pp. 2983-2991
    • Ely, E.W.1    Truman, B.2    Shintani, A.3
  • 10
    • 0037729416 scopus 로고    scopus 로고
    • BIS monitoring in ICU: Advantages of the new XP generation
    • Coluzzi F, Di Filippo C, Rosetti E, et al: BIS monitoring in ICU: Advantages of the new XP generation. Critical Care 2002; 6(Suppl 1):68
    • (2002) Critical Care , vol.6 , Issue.1 SUPPL. , pp. 68
    • Coluzzi, F.1    Di Filippo, C.2    Rosetti, E.3
  • 11
    • 0035006382 scopus 로고    scopus 로고
    • Validating the Sedation-Agitation Scale with the Bispectral Index and Visual Analog Scale in adult ICU patients after cardiac surgery
    • Riker RR, Fraser GL, Simmons LE, et al: Validating the Sedation-Agitation Scale with the Bispectral Index and Visual Analog Scale in adult ICU patients after cardiac surgery. Intensive Care Med 2001; 27:853-858
    • (2001) Intensive Care Med , vol.27 , pp. 853-858
    • Riker, R.R.1    Fraser, G.L.2    Simmons, L.E.3
  • 12
    • 0032818782 scopus 로고    scopus 로고
    • Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation Scale
    • Simmons LE, Riker RR, Prato BS, et al: Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation Scale. Crit Care Med 1999; 27:1499-1504
    • (1999) Crit Care Med , vol.27 , pp. 1499-1504
    • Simmons, L.E.1    Riker, R.R.2    Prato, B.S.3
  • 13
    • 3042691361 scopus 로고    scopus 로고
    • Can Bispectral Index monitoring predict recovery of consciousness in patients with severe brain injury?
    • Fabregas N, Gambus PL, Valero R, et al: Can Bispectral Index monitoring predict recovery of consciousness in patients with severe brain injury? Anesthesiology 2004; 101:43-51
    • (2004) Anesthesiology , vol.101 , pp. 43-51
    • Fabregas, N.1    Gambus, P.L.2    Valero, R.3
  • 14
    • 0030901893 scopus 로고    scopus 로고
    • Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers
    • Glass P, Bloom M, Kearse L, et al: Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers. Anesthesiology 1997; 86:836-847
    • (1997) Anesthesiology , vol.86 , pp. 836-847
    • Glass, P.1    Bloom, M.2    Kearse, L.3
  • 15
    • 1342288655 scopus 로고    scopus 로고
    • Artifact in the Bispectral Index in a patient with severe ischemic brain injury
    • Myles PS, Cairo S: Artifact in the Bispectral Index in a patient with severe ischemic brain injury. Anesth Analg 2004; 98:706-707
    • (2004) Anesth Analg , vol.98 , pp. 706-707
    • Myles, P.S.1    Cairo, S.2
  • 16
    • 3042781777 scopus 로고    scopus 로고
    • Monitoring depth of anaesthesia; Is it worth the effort?
    • Bonhomme V, Hans P: Monitoring depth of anaesthesia; Is it worth the effort? Eur J Anaesthesiol 2004; 21:423-428
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 423-428
    • Bonhomme, V.1    Hans, P.2
  • 17
    • 0038450015 scopus 로고    scopus 로고
    • Over-estimation of Bispectral Index in sedated intensive care unit patients revealed by administration of muscle relaxant
    • Vivien B, Di Maria S, Ouattara A, et al: Over-estimation of Bispectral Index in sedated intensive care unit patients revealed by administration of muscle relaxant. Anesthesiology 2003; 99:9-17
    • (2003) Anesthesiology , vol.99 , pp. 9-17
    • Vivien, B.1    Di Maria, S.2    Ouattara, A.3
  • 18
    • 1442332641 scopus 로고    scopus 로고
    • Is overestimation of Bispectral Index in sedated intensive care unit patients only related to electromyographic activity?
    • Fodale V, Santamaria LB: Is overestimation of Bispectral Index in sedated intensive care unit patients only related to electromyographic activity? Anesthesiology 2004; 100:746-747
    • (2004) Anesthesiology , vol.100 , pp. 746-747
    • Fodale, V.1    Santamaria, L.B.2
  • 19
    • 4344646927 scopus 로고    scopus 로고
    • Coadministration of propofol and midazolam decreases Bispectral Index value as a result of synergic muscle relaxant action on the motor system
    • Fodale V, Pratico C, Santamaria LB: Coadministration of propofol and midazolam decreases Bispectral Index value as a result of synergic muscle relaxant action on the motor system. Anesthesiology 2004; 101:799-801
    • (2004) Anesthesiology , vol.101 , pp. 799-801
    • Fodale, V.1    Pratico, C.2    Santamaria, L.B.3
  • 20
    • 0031657514 scopus 로고    scopus 로고
    • A primer for EEG signal processing in anesthesia
    • Rampil IJ: A primer for EEG signal processing in anesthesia. Anesthesiology 1998; 89:980-1002
    • (1998) Anesthesiology , vol.89 , pp. 980-1002
    • Rampil, I.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.