메뉴 건너뛰기




Volumn 62, Issue 2 SPEC. ISS., 2005, Pages 287-291

A new 2 methylalanine-PVC ESR dosimeter

Author keywords

2 Methyalanine; Dosimetry; EPR; PVC

Indexed keywords

AMINO ACIDS; CALIBRATION; DOSIMETRY; IONIZING RADIATION; MANGANESE; MODULATION; OPTIMIZATION; PARAMAGNETIC RESONANCE; POLYVINYL CHLORIDES; SIGNAL PROCESSING; SPECTROMETERS;

EID: 10644254403     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2004.08.041     Document Type: Conference Paper
Times cited : (7)

References (16)
  • 5
    • 0025818623 scopus 로고
    • Use of alanine-silicone pellets for electron paramagnetic resonance γ dosimetry
    • M.J. Flores, and S. Galindo Use of alanine-silicone pellets for electron paramagnetic resonance γ dosimetry Radiat. Res. 125 1991 335
    • (1991) Radiat. Res. , vol.125 , pp. 335
    • Flores, M.J.1    Galindo, S.2
  • 7
    • 0023259148 scopus 로고
    • The alanine radiation detector for high and low LET dosimetry
    • J.W. Hansen, K.J. Olsen, and M. Wille The alanine radiation detector for high and low LET dosimetry Radiat. Prot. Dos. 19 1987 43
    • (1987) Radiat. Prot. Dos. , vol.19 , pp. 43
    • Hansen, J.W.1    Olsen, K.J.2    Wille, M.3
  • 11
    • 0030293140 scopus 로고    scopus 로고
    • Dose - Response and fading characteristics of an alanine-agarose gel
    • S. Olsson, E. Lund, and R. Erickson Dose - response and fading characteristics of an alanine-agarose gel Appl. Radiat. Isot. 47 1996 1211
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1211
    • Olsson, S.1    Lund, E.2    Erickson, R.3
  • 12
    • 0036154782 scopus 로고    scopus 로고
    • EPR dosimetric properties of 2MA: EPR, ENDOR, and FT-EPR investigations
    • S. Olsson, E. Sagstuen, M. Bonora, and A. Lund EPR dosimetric properties of 2MA EPR, ENDOR, and FT-EPR investigations Radiat. Res. 157 2002 113
    • (2002) Radiat. Res. , vol.157 , pp. 113
    • Olsson, S.1    Sagstuen, E.2    Bonora, M.3    Lund, A.4
  • 14
    • 0023492781 scopus 로고
    • Continuos three-dimensional radiation dosimetry in tissue-equivalent phantoms using electron paramagnetic resonance in L-α-alanine
    • L. Wielopolski, M. Maryanski, B. Ciesielski, A. Forman, L.E. Reinstein, and A.G. Meek Continuos three-dimensional radiation dosimetry in tissue-equivalent phantoms using electron paramagnetic resonance in L-α-alanine Med. Phys. 14 1987 646
    • (1987) Med. Phys. , vol.14 , pp. 646
    • Wielopolski, L.1    Maryanski, M.2    Ciesielski, B.3    Forman, A.4    Reinstein, L.E.5    Meek, A.G.6
  • 15
    • 0032931020 scopus 로고    scopus 로고
    • Selfcalibrated alanine/EPR dosimeters: New generation of solid state/EPR dosimeters
    • N.D. Yordanov, and V. Gancheva Selfcalibrated alanine/EPR dosimeters new generation of solid state/EPR dosimeters J. Radioanal. Nucl. Chem. 240 1999 215
    • (1999) J. Radioanal. Nucl. Chem. , vol.240 , pp. 215
    • Yordanov, N.D.1    Gancheva, V.2
  • 16
    • 0032100469 scopus 로고    scopus 로고
    • Role of the matrix in the alanine-powder dosimetry
    • Z.P. Zagórski Role of the matrix in the alanine-powder dosimetry Radiat. Phys. Chem. 52 1998 575
    • (1998) Radiat. Phys. Chem. , vol.52 , pp. 575
    • Zagórski, Z.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.