Volumn 53, Issue 1, 2005, Pages 84-89

Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy

Author keywords

Femorotibial contact; Kinematics; Total knee arthroplasty; Visualization; X ray fluoroscopy

Indexed keywords

FLUORESCENCE; IMPLANTS (SURGICAL); PATIENT TREATMENT; X RAYS;

EID: 10644238009     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2003.09.018     Document Type: Article
Times cited : (52)

References (15)
  • 1
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material stresses in UHMWPE components for total joint replacement
    • Bartel D.L., Bickness V.L., Wright T.M. The effect of conformity, thickness, and material stresses in UHMWPE components for total joint replacement. J. Bone Joint Surg. 68(A):1989;1041-1051
    • (1989) J. Bone Joint Surg. , vol.68 , Issue.A , pp. 1041-1051
    • Bartel, D.L.1    Bickness, V.L.2    Wright, T.M.3
  • 2
    • 0026589837 scopus 로고
    • Wear of polyethylene in total joint replacement. Observations from retrieved PCA knee implants
    • Wright T.M., Rimnac C.M., Stulberg S.D. Wear of polyethylene in total joint replacement. Observations from retrieved PCA knee implants. Clin. Orthop. 276:1992;126-134
    • (1992) Clin. Orthop. , vol.276 , pp. 126-134
    • Wright, T.M.1    Rimnac, C.M.2    Stulberg, S.D.3
  • 3
    • 0038743328 scopus 로고    scopus 로고
    • The effects of external torque on polyethylene tibial insert damage patterns
    • Morra E.A., Postak P.D., Plaxton N.A., Greenwald A.S. The effects of external torque on polyethylene tibial insert damage patterns. Clin. Orthop. 410:2003;90-100
    • (2003) Clin. Orthop. , vol.410 , pp. 90-100
    • Morra, E.A.1    Postak, P.D.2    Plaxton, N.A.3    Greenwald, A.S.4
  • 4
    • 0030457410 scopus 로고    scopus 로고
    • Average and peak contact stress distribution evaluation of total knee arthroplasties
    • Szivek J.A., Anderson P.L., Benjamin J.B. Average and peak contact stress distribution evaluation of total knee arthroplasties. J. Arthroplasty. 11:1996;952-963
    • (1996) J. Arthroplasty , vol.11 , pp. 952-963
    • Szivek, J.A.1    Anderson, P.L.2    Benjamin, J.B.3
  • 5
    • 0032767377 scopus 로고    scopus 로고
    • An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: A comparison of k-scan sensor and fuji film
    • Harris M.L., Morberg P., Bruce W.J.M., Walsh W.R. An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of k-scan sensor and fuji film. J. Biomech. 32:1999;951-958
    • (1999) J. Biomech. , vol.32 , pp. 951-958
    • Harris, M.L.1    Morberg, P.2    Bruce, W.J.M.3    Walsh, W.R.4
  • 6
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks S.A., Hodge W.A. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans. Biomed. Eng. 43:1996;638-649
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 638-649
    • Banks, S.A.1    Hodge, W.A.2
  • 7
    • 0032189583 scopus 로고    scopus 로고
    • Three-dimensional determination of femoral-tibial contact positions under in-vivo conditions using fluoroscopy
    • Hoff W.A., Komistek R.D., Dennis D.A., Gabriel S.M., Walker S.A. Three-dimensional determination of femoral-tibial contact positions under in-vivo conditions using fluoroscopy. Clin. Biomech. 13:1998;455-472
    • (1998) Clin. Biomech. , vol.13 , pp. 455-472
    • Hoff, W.A.1    Komistek, R.D.2    Dennis, D.A.3    Gabriel, S.M.4    Walker, S.A.5
  • 9
    • 0029375767 scopus 로고
    • A new method for distortion correction of electronic endoscope images
    • Haneishi H., Yagihashi Y., Miyake Y. A new method for distortion correction of electronic endoscope images. IEEE Trans. Med. Imag. 14:1995;548-555
    • (1995) IEEE Trans. Med. Imag. , vol.14 , pp. 548-555
    • Haneishi, H.1    Yagihashi, Y.2    Miyake, Y.3
  • 13
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood E.S., Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J. Biomech. Eng. 15:1983;136-144
    • (1983) J. Biomech. Eng. , vol.15 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 15
    • 0033028923 scopus 로고    scopus 로고
    • Knee cartilage topography, thickness, and contact areas from MRI: In-vitro calibration and in-vivo measurements
    • Cohen Z.A., McCarthy D.M., Kwak S.D. Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements. Osteoarthritis Cart. 7:1999;95-109
    • (1999) Osteoarthritis Cart. , vol.7 , pp. 95-109
    • Cohen, Z.A.1    McCarthy, D.M.2    Kwak, S.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.