메뉴 건너뛰기




Volumn 39, Issue 12, 2004, Pages 2431-2437

Cell-based CMOS sensor and actuator arrays

Author keywords

Cell manipulation; Cell based biosensors; Dielectrophoresis; Extracellular recording; Image sensors; In vitro; Multielectrode array (MEA); Multisite recording; Neurons

Indexed keywords

ACTUATORS; ARRAYS; BIOELECTRIC PHENOMENA; CELLS; CMOS INTEGRATED CIRCUITS; ELECTROPHORESIS; IMAGE SENSORS; NEUROLOGY; TISSUE;

EID: 10444222533     PISSN: 00189200     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSSC.2004.837082     Document Type: Conference Paper
Times cited : (30)

References (32)
  • 1
    • 35649001607 scopus 로고
    • A quantitative description of membrane current and its application to conduction and excitation in nerve
    • A. L. Hodgkin and A. F. Huxley, "A quantitative description of membrane current and its application to conduction and excitation in nerve," J. Physiol, vol. 117, pp. 500-544, 1952.
    • (1952) J. Physiol , vol.117 , pp. 500-544
    • Hodgkin, A.L.1    Huxley, A.F.2
  • 2
    • 0034302212 scopus 로고    scopus 로고
    • Drug evaluations using neuronal networks cultured on microelectrode arrays
    • S. I. Morefield, E. W. Keefer, K. D. Chapman, and G. W. Gross, "Drug evaluations using neuronal networks cultured on microelectrode arrays," Biosens. & Bioelectronics, vol. 15, pp. 383-396, 2000.
    • (2000) Biosens. & Bioelectronics , vol.15 , pp. 383-396
    • Morefield, S.I.1    Keefer, E.W.2    Chapman, K.D.3    Gross, G.W.4
  • 4
    • 0036139943 scopus 로고    scopus 로고
    • Two-dimensional monitoring of spiking networks in acute brain slices
    • U. Egert, D. Heck, and A. Aertsen, "Two-dimensional monitoring of spiking networks in acute brain slices," Exp Brain Res., vol. 142, no. 2, pp. 268-274, 2002.
    • (2002) Exp Brain Res. , vol.142 , Issue.2 , pp. 268-274
    • Egert, U.1    Heck, D.2    Aertsen, A.3
  • 5
    • 0019441262 scopus 로고
    • Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches
    • O. P. Hamill, A. Marty, E. Neher, B. Sakmann, and F. J. Sigworth, "Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches," Pflügers Arch., vol. 391, pp. 85-100, 1981.
    • (1981) Pflügers Arch. , vol.391 , pp. 85-100
    • Hamill, O.P.1    Marty, A.2    Neher, E.3    Sakmann, B.4    Sigworth, F.J.5
  • 6
    • 0041442531 scopus 로고    scopus 로고
    • Optical recording from individual neurons in culture
    • H. Johansson, Ed. Berlin, Germany: Springer-Verlag
    • A. Bullen and P. Saggau, "Optical recording from individual neurons in culture," in Modern Techniques in Neuroscience Research, 1st ed, H. Johansson, Ed. Berlin, Germany: Springer-Verlag, 1999, p. 89.
    • (1999) Modern Techniques in Neuroscience Research, 1st Ed. , pp. 89
    • Bullen, A.1    Saggau, P.2
  • 7
    • 0002637831 scopus 로고    scopus 로고
    • Fluorescence and photochemical probes of dynamic biochemical signals inside living cells
    • A. W. Czarnik, Ed. Washington, DC: American Chemical Society
    • R. Y. Tsien, "Fluorescence and photochemical probes of dynamic biochemical signals inside living cells," in Fluorescent Chemosensors for Ions and Molecule Recognition, A. W. Czarnik, Ed. Washington, DC: American Chemical Society, pp. 130-146.
    • Fluorescent Chemosensors for Ions and Molecule Recognition , pp. 130-146
    • Tsien, R.Y.1
  • 8
    • 0001376902 scopus 로고
    • Neuron-transistor: Electrical transfer function measured by the patch-clamp technique
    • P. Fromherz, C. O. Müller, and R. Weis, "Neuron-transistor: electrical transfer function measured by the patch-clamp technique," Phys. Rev. Lett., vol. 71, pp. 4079-4082, 1993.
    • (1993) Phys. Rev. Lett. , vol.71 , pp. 4079-4082
    • Fromherz, P.1    Müller, C.O.2    Weis, R.3
  • 9
    • 0031843133 scopus 로고    scopus 로고
    • Neuron-silicon junction with voltage-gated ionic currents
    • R. Schätzthauer and P. Fromherz, "Neuron-silicon junction with voltage-gated ionic currents," Eur. J. Neurosci., vol. 10, pp. 1956-1962, 1998.
    • (1998) Eur. J. Neurosci. , vol.10 , pp. 1956-1962
    • Schätzthauer, R.1    Fromherz, P.2
  • 10
    • 0032939182 scopus 로고    scopus 로고
    • Extracellular recording with transistors and the distribution of ionic conductances in a cell membrane
    • P. Fromherz, "Extracellular recording with transistors and the distribution of ionic conductances in a cell membrane," Eur. Biophys. J., vol. 28, pp. 254-258, 1999.
    • (1999) Eur. Biophys. J. , vol.28 , pp. 254-258
    • Fromherz, P.1
  • 11
    • 0015396686 scopus 로고
    • A miniature microelectrode array to monitor the bioelectric activity of cultured cells
    • C. A. Thomas, P. A. Springer Jr., G. E. Loeb, Y. Berwald-Netter, and L. M. Okun, "A miniature microelectrode array to monitor the bioelectric activity of cultured cells," Exp. Cell Res., vol. 74, pp. 61-66, 1972.
    • (1972) Exp. Cell Res. , vol.74 , pp. 61-66
    • Thomas, C.A.1    Springer Jr., P.A.2    Loeb, G.E.3    Berwald-Netter, Y.4    Okun, L.M.5
  • 12
    • 0018899387 scopus 로고
    • Recording action potentials from cultured neurons with extracellular microcircuit electrodes
    • J. Pine, "Recording action potentials from cultured neurons with extracellular microcircuit electrodes," J. Neurosci. Methods, vol. 2, pp. 19-31, 1980.
    • (1980) J. Neurosci. Methods , vol.2 , pp. 19-31
    • Pine, J.1
  • 13
    • 0028596541 scopus 로고
    • A thin film microelectrode array for monitoring extracellular neuronal activity in vitro
    • W. Nisch, J. Böck, U. Egert, H. Hämmerle, and A. Mohr, "A thin film microelectrode array for monitoring extracellular neuronal activity in vitro," Biosensors Bioelectron., vol. 9, pp. 737-741, 1994.
    • (1994) Biosensors Bioelectron. , vol.9 , pp. 737-741
    • Nisch, W.1    Böck, J.2    Egert, U.3    Hämmerle, H.4    Mohr, A.5
  • 14
    • 0017759085 scopus 로고
    • A new fixed-array multimicroelectrode system designed for longterm monitoring of extracellular single unit neuronal activity in vitro
    • G. W. Gross, E. Rieske, G. W. Kreutzberg, and A. Meyer, "A new fixed-array multimicroelectrode system designed for longterm monitoring of extracellular single unit neuronal activity in vitro," Neurosci. Lett., vol. 6, pp. 101-105, 1977.
    • (1977) Neurosci. Lett. , vol.6 , pp. 101-105
    • Gross, G.W.1    Rieske, E.2    Kreutzberg, G.W.3    Meyer, A.4
  • 15
    • 0032728994 scopus 로고    scopus 로고
    • A new planar multielectrode array for extracellular recording: Application to hippocampal acute slice
    • H. Oka, K. Shimono, R. Ogawa, H. Sugihara, and M. Taketani, "A new planar multielectrode array for extracellular recording: application to hippocampal acute slice," J. Neurosci. Methods, vol. 93, pp. 61-67, 1999.
    • (1999) J. Neurosci. Methods , vol.93 , pp. 61-67
    • Oka, H.1    Shimono, K.2    Ogawa, R.3    Sugihara, H.4    Taketani, M.5
  • 16
    • 0017101877 scopus 로고
    • Extracellular potential recordings by means of a field effect transistor without gate metal, called OSFET
    • P. Bergveld, J. Wiersma, and H. Meertens, "Extracellular potential recordings by means of a field effect transistor without gate metal, called OSFET," IEEE Trans. Biomed. Eng., vol. BME-23, no. 2, pp. 136-144, 1976.
    • (1976) IEEE Trans. Biomed. Eng. , vol.BME-23 , Issue.2 , pp. 136-144
    • Bergveld, P.1    Wiersma, J.2    Meertens, H.3
  • 17
    • 0026434555 scopus 로고
    • A neuron-silicon junction: A retzius-cell of the leech on an insulated-gate field-effect transistor
    • P. Fromherz, A. Offenhäusser, T. Vetter, and J. Weis, "A neuron-silicon junction: a retzius-cell of the leech on an insulated-gate field-effect transistor," Science, vol. 252, pp. 1290-1293, 1991.
    • (1991) Science , vol.252 , pp. 1290-1293
    • Fromherz, P.1    Offenhäusser, A.2    Vetter, T.3    Weis, J.4
  • 19
    • 0022367558 scopus 로고
    • Transparent indium-tin oxide electrode patterns for extracellular, multisite recording in neuronal cultures
    • G. W. Gross, W. Y. Chen, and J. W. Lin, "Transparent indium-tin oxide electrode patterns for extracellular, multisite recording in neuronal cultures," J. Neurosci. Methods, vol. 15, pp. 243-252, 1985.
    • (1985) J. Neurosci. Methods , vol.15 , pp. 243-252
    • Gross, G.W.1    Chen, W.Y.2    Lin, J.W.3
  • 20
    • 0036455161 scopus 로고    scopus 로고
    • Transistor array with organotypic brain slice: Field potential records and synaptic currents
    • B. Besl and P. Fromherz, "Transistor array with organotypic brain slice: field potential records and synaptic currents," Eur. J. Neurosci., vol. 15, pp. 999-1005, 2002.
    • (2002) Eur. J. Neurosci. , vol.15 , pp. 999-1005
    • Besl, B.1    Fromherz, P.2
  • 21
    • 0033366305 scopus 로고    scopus 로고
    • Membrane-transistor with giant lipid vesicle touching a silicon chip
    • P. Fromherz, V. Kiessling, K. Kottig, and G. Zeck, "Membrane-transistor with giant lipid vesicle touching a silicon chip," Appl. Phys., pp. 571-576, 1999.
    • (1999) Appl. Phys. , pp. 571-576
    • Fromherz, P.1    Kiessling, V.2    Kottig, K.3    Zeck, G.4
  • 22
    • 5544304727 scopus 로고    scopus 로고
    • Two-way silicon-neuron interface by electrical induction
    • A. Stett, B. Müller, and P. Fromherz, "Two-way silicon-neuron interface by electrical induction," Phys. Rev. E, vol. 55, pp. 1779-1782, 1997.
    • (1997) Phys. Rev. E , vol.55 , pp. 1779-1782
    • Stett, A.1    Müller, B.2    Fromherz, P.3
  • 24
    • 0033083227 scopus 로고    scopus 로고
    • The neurochip: A new multielectrode device for stimulating and recording from cultured neurons
    • M. P. Maher, J. Pine, J. Wright, and Y.-C. Tai, "The neurochip: a new multielectrode device for stimulating and recording from cultured neurons," J. Neurosci. Meth., vol. 87, pp. 45-56, 1999.
    • (1999) J. Neurosci. Meth. , vol.87 , pp. 45-56
    • Maher, M.P.1    Pine, J.2    Wright, J.3    Tai, Y.-C.4
  • 25
    • 0035964350 scopus 로고    scopus 로고
    • Noninvasive neuroelectronic interfacing with synaptically connected snail neurons immobilized on a semiconductor chip
    • G. Zeck and P. Fromherz, "Noninvasive neuroelectronic interfacing with synaptically connected snail neurons immobilized on a semiconductor chip," Proc. Natl. Acad. Sci. USA, vol. 98, pp. 10457-10462, 2001.
    • (2001) Proc. Natl. Acad. Sci. USA , vol.98 , pp. 10457-10462
    • Zeck, G.1    Fromherz, P.2
  • 26
    • 0032202373 scopus 로고    scopus 로고
    • The dielectrophoretic movement and positioning of a biological cell using a three-dimensional grid electrode system
    • J. Sueheiro and R. Pethig, "The dielectrophoretic movement and positioning of a biological cell using a three-dimensional grid electrode system," J. Phys. D, Appl. Phys., vol. 31, pp. 3298-3305, 1998.
    • (1998) J. Phys. D, Appl. Phys. , vol.31 , pp. 3298-3305
    • Sueheiro, J.1    Pethig, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.