메뉴 건너뛰기




Volumn 42, Issue 1, 2004, Pages 142-144

Estimation of the size of air emboli detectable by electrical impedance measurement

Author keywords

Air emboli; Biological tissue; Bubble; Electrical impedance measurement; Non invasive detection

Indexed keywords

AIR; ARRAYS; BLOOD; BUBBLES (IN FLUIDS); ELECTRIC IMPEDANCE MEASUREMENT; ELECTRODES; NONINVASIVE MEDICAL PROCEDURES; VIDEO CAMERAS;

EID: 1042280278     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02351024     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 0034499907 scopus 로고    scopus 로고
    • 'Bipolar and tetrapolar transfer impedance measurements from a volume conductor'
    • Brown, B. H., Wilson, A. J., and Bertemes-Filho, P. (2000): 'Bipolar and tetrapolar transfer impedance measurements from a volume conductor', Electron. Lett., 36, pp. 2060-2062
    • (2000) Electron. Lett. , vol.36 , pp. 2060-2062
    • Brown, B.H.1    Wilson, A.J.2    Bertemes-Filho, P.3
  • 2
    • 0030169891 scopus 로고    scopus 로고
    • 'A review of electrical impedance techniques for the measurement of multiphase flows'
    • Ceccio, S. L., and George, D. L. (1996): 'A review of electrical impedance techniques for the measurement of multiphase flows', J. Fluids Eng., 118, pp. 391-398
    • (1996) J. Fluids Eng. , vol.118 , pp. 391-398
    • Ceccio, S.L.1    George, D.L.2
  • 3
    • 0027887893 scopus 로고
    • 'Electrical impedance method for flow regime identification in vertical upward gas - Liquid two-phase flow'
    • Das, R. K., and Pattanayak, S. (1993): 'Electrical impedance method for flow regime identification in vertical upward gas - liquid two-phase flow', Meas. Sci. Technol, 4, pp. 1457-1463
    • (1993) Meas. Sci. Technol. , vol.4 , pp. 1457-1463
    • Das, R.K.1    Pattanayak, S.2
  • 4
    • 0014986362 scopus 로고
    • 'An application of electrocardiographic lead theory to impedance plethysmography'
    • Geselowitz, D. B. (1971): 'An application of electrocardiographic lead theory to impedance plethysmography', IEEE Trans. Bio-med. Eng., 18, pp. 38-41
    • (1971) IEEE Trans. Bio-med. Eng. , vol.18 , pp. 38-41
    • Geselowitz, D.B.1
  • 5
    • 0022664397 scopus 로고
    • 'Use of electrical impedance method measuring two phase flow parameters'
    • Huahun, G. (1987): 'Use of electrical impedance method measuring two phase flow parameters', IEEE Trans. Nucl. Sci., 34, pp. 553-557
    • (1987) IEEE Trans. Nucl. Sci. , vol.34 , pp. 553-557
    • Huahun, G.1
  • 6
    • 0028276263 scopus 로고
    • 'A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli'
    • Leathard, A. D., Brown, B. H., Campbell, J., Zhang, F., Morice, A. H., and Tayler, D. (1994): 'A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli', Physiol. Meas., 15, pp. A137-A146
    • (1994) Physiol. Meas. , vol.15
    • Leathard, A.D.1    Brown, B.H.2    Campbell, J.3    Zhang, F.4    Morice, A.H.5    Tayler, D.6
  • 7
    • 0027434362 scopus 로고
    • 'Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in-vitro model'
    • Markus, H. S., and Brown, M. M. (1993): 'Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in-vitro model', Stroke, 24, pp. 1-5
    • (1993) Stroke , vol.24 , pp. 1-5
    • Markus, H.S.1    Brown, M.M.2
  • 8
    • 13344262689 scopus 로고    scopus 로고
    • 'Three-dimensional electrical impedance tomography'
    • Metherall, P., Barber, D. C., Smallwood, R. H., and Brown, B. H. (1996): 'Three-dimensional electrical impedance tomography', Nature, 380, pp. 509-512
    • (1996) Nature , vol.380 , pp. 509-512
    • Metherall, P.1    Barber, D.C.2    Smallwood, R.H.3    Brown, B.H.4
  • 9
    • 0033336061 scopus 로고    scopus 로고
    • 'The measurement of high frequency electrical transfer impedances from biological tissues'
    • Nebuya, S., Brown, B. H., Smallwood, R. H., Milnes, P., Waterworth, A. R., and Noshiro, M. (1999): 'The measurement of high frequency electrical transfer impedances from biological tissues', Electron. Lett., 35, pp, 1985-1987
    • (1999) Electron. Lett. , vol.35 , pp. 1985-1987
    • Nebuya, S.1    Brown, B.H.2    Smallwood, R.H.3    Milnes, P.4    Waterworth, A.R.5    Noshiro, M.6
  • 10
    • 0022034118 scopus 로고
    • 'Qualitative and quantitative methods for investigating gas emboli in blood'
    • Richardson, P. D. (1985): 'Qualitative and quantitative methods for investigating gas emboli in blood', Med. Instrum., 19, pp. 55-58
    • (1985) Med. Instrum. , vol.19 , pp. 55-58
    • Richardson, P.D.1
  • 11
    • 0014519438 scopus 로고
    • 'Experiments on decompression bubbles in the circulation using ultrasonic and electromagnetic flowmeters'
    • Spencer, M. P., Campbell, S. D., Sealy, J. L., Henry, F. C., and Lindbergh, J. (1969): 'Experiments on decompression bubbles in the circulation using ultrasonic and electromagnetic flowmeters', J. Occup. Med., 11, pp. 238-244
    • (1969) J. Occup. Med. , vol.11 , pp. 238-244
    • Spencer, M.P.1    Campbell, S.D.2    Sealy, J.L.3    Henry, F.C.4    Lindbergh, J.5
  • 12
    • 0017255075 scopus 로고
    • 'Decompression limits for compressed air determined by ultrasonically detected blood bubbles'
    • Spencer, M. P. (1976): 'Decompression limits for compressed air determined by ultrasonically detected blood bubbles', J. Appl. Physiol., 40, pp. 229-235
    • (1976) J. Appl. Physiol. , vol.40 , pp. 229-235
    • Spencer, M.P.1
  • 13
    • 0025317321 scopus 로고
    • 'Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography'
    • Spencer, M. P., Thomas, G. I., Nicholls, S. C., and Sauvage, L. R. (1990): 'Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography', Stroke, 21, pp. 415-423
    • (1990) Stroke , vol.21 , pp. 415-423
    • Spencer, M.P.1    Thomas, G.I.2    Nicholls, S.C.3    Sauvage, L.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.