메뉴 건너뛰기




Volumn 17, Issue 6, 2004, Pages 517-520

Capnometry in the spontaneously breathing patient

Author keywords

Acid base disorder; Capnography; Sedation; Sleep disorder; Spontaneous breathing

Indexed keywords

CARBON DIOXIDE;

EID: 10344248941     PISSN: 09527907     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001503-200412000-00013     Document Type: Review
Times cited : (14)

References (19)
  • 1
    • 0006148339 scopus 로고    scopus 로고
    • Section: Pulmonary ventilation. Approved by the House of Delegates on 25 October 1995, last amended on October 17
    • American Society of Anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Section: Pulmonary ventilation. Approved by the House of Delegates on 25 October 1995, last amended on October 17, 2001. http://www.asahq.org/publicationsAndServices/practiceparam.htm. [Accessed 3 September 2004].
    • (2001) Practice Guidelines for Sedation and Analgesia by Non-anesthesiologists
  • 2
    • 0036615783 scopus 로고    scopus 로고
    • Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy
    • Vargo JJ, Zuccaro G Jr, Dumot JA, et al. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc 2002; 55:826-831.
    • (2002) Gastrointest Endosc , vol.55 , pp. 826-831
    • Vargo, J.J.1    Zuccaro Jr., G.2    Dumot, J.A.3
  • 3
    • 0042388525 scopus 로고    scopus 로고
    • Safety of nonanesthetist sedation with propofol for outpatient colonoscopy and esophagogastroduodenoscopy
    • Kulling D, Rothenbuhler R, Inauen W. Safety of nonanesthetist sedation with propofol for outpatient colonoscopy and esophagogastroduodenoscopy. Endoscopy 2003; 35:679-682. End-tidal carbon dioxide monitoring used during endoscopy during propofol sedation by non-anesthesiologists.
    • (2003) Endoscopy , vol.35 , pp. 679-682
    • Kulling, D.1    Rothenbuhler, R.2    Inauen, W.3
  • 4
    • 0041858036 scopus 로고    scopus 로고
    • Capnographic monitoring of ventilatory status during moderate (conscious) sedation
    • Koniaris LG, Wilson S, Drugas G, Simmons W. Capnographic monitoring of ventilatory status during moderate (conscious) sedation. Surg Endosc 2003; 17:1261-1265. Large restrospective study looking into whether capnography decreases adverse events during sedation.
    • (2003) Surg Endosc , vol.17 , pp. 1261-1265
    • Koniaris, L.G.1    Wilson, S.2    Drugas, G.3    Simmons, W.4
  • 6
    • 0345707609 scopus 로고    scopus 로고
    • Effects of IV pentobarbital with and without fentanyl on end-tidal carbon dioxide levels during deep sedation of pediatric patients undergoing MRI
    • Connor L, Burrows PE, Zurakowski D, et al. Effects of IV pentobarbital with and without fentanyl on end-tidal carbon dioxide levels during deep sedation of pediatric patients undergoing MRI. Am J Roentgenol 2003; 181:1691-1694. Safety of sedation during MRI with addition of end-tidal carbon dioxide monitoring.
    • (2003) Am J Roentgenol , vol.181 , pp. 1691-1694
    • Connor, L.1    Burrows, P.E.2    Zurakowski, D.3
  • 7
    • 0038025737 scopus 로고    scopus 로고
    • Survey of use of end-tidal carbon dioxide for confirming tracheal tube placement in intensive care units in the UK
    • Kannan S, Manji M. Survey of use of end-tidal carbon dioxide for confirming tracheal tube placement in intensive care units in the UK. Anaesthesia 2003; 58:476-479.
    • (2003) Anaesthesia , vol.58 , pp. 476-479
    • Kannan, S.1    Manji, M.2
  • 8
    • 1642295568 scopus 로고    scopus 로고
    • The value of capnography during sedation or sedation/analgesia in pediatric minor procedures
    • Yldzdas D, Yapcoglu H, Ylmaz HL. The value of capnography during sedation or sedation/analgesia in pediatric minor procedures. Pediatr Emerg Care 2004; 20:162-165. Use of capnography during sedation for minor procedures in the intensive care unit.
    • (2004) Pediatr Emerg Care , vol.20 , pp. 162-165
    • Yldzdas, D.1    Yapcoglu, H.2    Ylmaz, H.L.3
  • 9
    • 0037335659 scopus 로고    scopus 로고
    • Tight control of prehospital ventilation by capnography in major trauma victims
    • Helm M, Schuster R, Hauke J, Lampl L. Tight control of prehospital ventilation by capnography in major trauma victims. Br J Anaesth 2003; 90:327-332.
    • (2003) Br J Anaesth , vol.90 , pp. 327-332
    • Helm, M.1    Schuster, R.2    Hauke, J.3    Lampl, L.4
  • 10
    • 2042465896 scopus 로고    scopus 로고
    • The use of quantitative end-tidal capnometry to avoid inadvertent severe hyperventilation in patients with head injury after paramedic rapid sequence intubation
    • Davis DP, Dunford JV, Ochs M, et al. The use of quantitative end-tidal capnometry to avoid inadvertent severe hyperventilation in patients with head injury after paramedic rapid sequence intubation. J Trauma 2004; 56:808-814.
    • (2004) J Trauma , vol.56 , pp. 808-814
    • Davis, D.P.1    Dunford, J.V.2    Ochs, M.3
  • 11
    • 3042686493 scopus 로고    scopus 로고
    • Air medical transport of severely head-injured patients undergoing paramedic rapid sequence intubation
    • Poste JC, Davis DP, Ochs M, et al. Air medical transport of severely head-injured patients undergoing paramedic rapid sequence intubation. Air Med J 2004; 23:36-40.
    • (2004) Air Med J , vol.23 , pp. 36-40
    • Poste, J.C.1    Davis, D.P.2    Ochs, M.3
  • 12
    • 0346733076 scopus 로고    scopus 로고
    • Capnography in non-tracheally intubated emergency patients as an additional tool in pulse oximetry for prehospital monitoring of respiration
    • Kober A, Schubert B, Bertalanffy P, et al. Capnography in non-tracheally intubated emergency patients as an additional tool in pulse oximetry for prehospital monitoring of respiration. Anesth Analg 2004; 98:206-210. Capnography in pre-hospital settings show fewer periods of malfunction when compared to pulse oximetry.
    • (2004) Anesth Analg , vol.98 , pp. 206-210
    • Kober, A.1    Schubert, B.2    Bertalanffy, P.3
  • 13
    • 0037325940 scopus 로고    scopus 로고
    • Ventilatory response during dissociative sedation in children - A pilot study
    • Kim G, Green SM, Denmark TK, Krauss B. Ventilatory response during dissociative sedation in children - a pilot study. Acad Emerg Med 2003; 10:140-145. This study focuses on respiratory depression as measured by end-tidal carbon dioxide during use of ketamine in the emergency department.
    • (2003) Acad Emerg Med , vol.10 , pp. 140-145
    • Kim, G.1    Green, S.M.2    Denmark, T.K.3    Krauss, B.4
  • 14
    • 1642407801 scopus 로고    scopus 로고
    • Volumetric capnography as a screening test for pulmonary embolism in the emergency department
    • Verschuren F, Liistro G, Coffeng R, et al. Volumetric capnography as a screening test for pulmonary embolism in the emergency department. Chest 2004; 125:841-850. Use of volumetric capnography in patients with suspected pulmonary embolism. This technique may be used in the future for diagnostic work-up of pulmonary embolism.
    • (2004) Chest , vol.125 , pp. 841-850
    • Verschuren, F.1    Liistro, G.2    Coffeng, R.3
  • 15
    • 0036895679 scopus 로고    scopus 로고
    • End-tidal carbon dioxide predicts the presence and severity of acidosis in children with diabetes
    • Fearon DM, Steele DW. End-tidal carbon dioxide predicts the presence and severity of acidosis in children with diabetes. Acad Emerg Med 2002; 9:1373-1378.
    • (2002) Acad Emerg Med , vol.9 , pp. 1373-1378
    • Fearon, D.M.1    Steele, D.W.2
  • 16
    • 0142057047 scopus 로고    scopus 로고
    • Capnometry for noninvasive continuous monitoring of metabolic status in pediatric diabetic ketoacidosis
    • Garcia E, Abramo TJ, Okada P, et al. Capnometry for noninvasive continuous monitoring of metabolic status in pediatric diabetic ketoacidosis. Crit Care Med 2003; 31:2539-2543. Capnometry used as a non-invasive monitor of metabolic status in pediatric diabetic ketoacidosis. This non-invasive monitor had a close positive correlation to venous carbon dioxide and pH and an inverse relationship with respiratory rate.
    • (2003) Crit Care Med , vol.31 , pp. 2539-2543
    • Garcia, E.1    Abramo, T.J.2    Okada, P.3
  • 17
    • 0038127154 scopus 로고    scopus 로고
    • Methodik der Atmungsmessung im Schlaf: Kapnographie zur Beurteilung der Ventilation
    • Berlin
    • Schafer T. Methodik der Atmungsmessung im Schlaf: Kapnographie zur Beurteilung der Ventilation [in German] [Method for measuring respiration in sleep: capnography for determining ventilation]. Biomed Tech (Berlin) 2003; 48:170-175. Use of capnography in sleep-related disorders.
    • (2003) Biomed Tech , vol.48 , pp. 170-175
    • Schafer, T.1
  • 18
    • 4644262940 scopus 로고    scopus 로고
    • Lung cancer pulse oximetry and capnography in lung function laboratories
    • Giner J, Casan P. Lung cancer pulse oximetry and capnography in lung function laboratories. Arch Bronconeumol 2004; 40:311-314. Newer uses for capnography.
    • (2004) Arch Bronconeumol , vol.40 , pp. 311-314
    • Giner, J.1    Casan, P.2
  • 19
    • 0037406654 scopus 로고    scopus 로고
    • 2 in spontaneously breathing patients
    • 2 in spontaneously breathing patients. Respir Med 2003; 97:476-481. Portable capnometry is feasible and could be a valuable in-house monitoring device.
    • (2003) Respir Med , vol.97 , pp. 476-481
    • Takano, Y.1    Sakamoto, O.2    Kiyofuji, C.3    Ito, K.4