메뉴 건너뛰기




Volumn 15, Issue 12, 2004, Pages 1399-1405

Device migration after endovascular abdominal aortic aneurysm repair: Experience with a Talent stent-graft

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; ANEURYSM SURGERY; AORTA GRAFT; CELIAC ARTERY; COMPUTER ASSISTED TOMOGRAPHY; DEMOGRAPHY; ENDOLEAK; ENDOVASCULAR SURGERY; FEMALE; FOLLOW UP; GRAFT FAILURE; HUMAN; MAJOR CLINICAL STUDY; MALE; MORTALITY; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; REOPERATION; REVIEW; RISK FACTOR; STENT; SUPERIOR MESENTERIC ARTERY; TREATMENT FAILURE; TREATMENT OUTCOME;

EID: 10344231449     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.RVI.0000142601.10673.00     Document Type: Article
Times cited : (30)

References (15)
  • 1
    • 0036482632 scopus 로고    scopus 로고
    • Efficacy of a bifurcated endograft versus open repair of abdominal aortic aneurysms: A reappraisal
    • Makaroun MS, Chaikof E, Naslund T, Matsumura J. Efficacy of a bifurcated endograft versus open repair of abdominal aortic aneurysms: a reappraisal. J Vasc Surg 2002; 35:203-210.
    • (2002) J Vasc Surg , vol.35 , pp. 203-210
    • Makaroun, M.S.1    Chaikof, E.2    Naslund, T.3    Matsumura, J.4
  • 2
    • 0037696294 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms: Device-specific outcome
    • Ouriel K, Clair DG, Greenberg RK, et al. Endovascular repair of abdominal aortic aneurysms: Device-specific outcome. J Vasc Surg 2003; 37:991-998.
    • (2003) J Vasc Surg , vol.37 , pp. 991-998
    • Ouriel, K.1    Clair, D.G.2    Greenberg, R.K.3
  • 4
    • 0036733325 scopus 로고    scopus 로고
    • Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: A cautionary note
    • Conners III M, Sternbergh III W, Carter G, Tonnessen B, Yoselevitz M, Money S. Endograft migration one to four years after endovascular abdominal aortic aneurysm repair with the AneuRx device: A cautionary note. J Vasc Surg 2002; 36:476-484.
    • (2002) J Vasc Surg , vol.36 , pp. 476-484
    • Conners III, M.1    Sternbergh III, W.2    Carter, G.3    Tonnessen, B.4    Yoselevitz, M.5    Money, S.6
  • 5
    • 0037380847 scopus 로고    scopus 로고
    • The US AneuRx Clinical Trial: 6-year clinical update 2002
    • Zarins CK. The US AneuRx Clinical Trial: 6-year clinical update 2002. J Vasc Surg 2003; 37:904-908.
    • (2003) J Vasc Surg , vol.37 , pp. 904-908
    • Zarins, C.K.1
  • 7
    • 0036481881 scopus 로고    scopus 로고
    • Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years
    • Cao P, Verzini F, Zannetti S, et al. Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years. J Vasc Surg 2002; 35:229-235.
    • (2002) J Vasc Surg , vol.35 , pp. 229-235
    • Cao, P.1    Verzini, F.2    Zannetti, S.3
  • 8
    • 0346964283 scopus 로고    scopus 로고
    • Influence of endograft oversizing on device migration, endoleak, aneursym shrinkage, and aortic neck dilation: Results from the Zenith multicenter trial
    • Sternbergh III WC, Money SR, Greenberg RK, Chuter TAM. Influence of endograft oversizing on device migration, endoleak, aneursym shrinkage, and aortic neck dilation: Results from the Zenith multicenter trial. J Vasc Surg 2004; 39:20-26.
    • (2004) J Vasc Surg , vol.39 , pp. 20-26
    • Sternbergh III, W.C.1    Money, S.R.2    Greenberg, R.K.3    Chuter, T.A.M.4
  • 10
    • 0035117760 scopus 로고    scopus 로고
    • Update on the Talent aortic stent-graft: A preliminary report from United States phase I and II trials
    • Criado FJ, Wilson EP, Fairman RM, Abul-Khoudoud O, Wellons E. Update on the Talent aortic stent-graft: a preliminary report from United States phase I and II trials. J Vasc Surg 2001; 33:5146-149.
    • (2001) J Vasc Surg , vol.33 , pp. 5146-5149
    • Criado, F.J.1    Wilson, E.P.2    Fairman, R.M.3    Abul-Khoudoud, O.4    Wellons, E.5
  • 12
    • 19044393090 scopus 로고    scopus 로고
    • Reporting standards for endovascular aortic aneurysm repair
    • Chaikof EL, Blankensteijn JD, Harris PL, et al. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg 2002; 35:1048-1060.
    • (2002) J Vasc Surg , vol.35 , pp. 1048-1060
    • Chaikof, E.L.1    Blankensteijn, J.D.2    Harris, P.L.3
  • 13
    • 0034164052 scopus 로고    scopus 로고
    • Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms
    • Albertini JN, Kalliafas S, Travis S, et al. Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 2000; 19:308-312.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 308-312
    • Albertini, J.N.1    Kalliafas, S.2    Travis, S.3
  • 14
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977; 33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 15
    • 0031058054 scopus 로고    scopus 로고
    • Changing aneurysm morphology after endovascular grafting: Relation to leakage or persistent perfusion
    • Malina M, Ivancev K, Chuter TAM, et al. Changing aneurysm morphology after endovascular grafting: relation to leakage or persistent perfusion. J Endovasc Surg 1997; 4:23-30.
    • (1997) J Endovasc Surg , vol.4 , pp. 23-30
    • Malina, M.1    Ivancev, K.2    Chuter, T.A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.