메뉴 건너뛰기




Volumn 5, Issue 4, 2004, Pages 177-183

Secure tuberosity fixation in shoulder arthroplasty for fractures

Author keywords

Fixation; Fracture; Hemiarthroplasty; Proximal humerus; Tuberosity

Indexed keywords

ARTHROPLASTY; ARTICLE; BICEPS BRACHII MUSCLE; COMORBIDITY; FRACTURE FIXATION; HUMAN; HUMERUS FRACTURE; HUMERUS HEAD; PATIENT POSITIONING; POSTOPERATIVE CARE; POSTOPERATIVE COMPLICATION; PREOPERATIVE EVALUATION; SHOULDER ARTHROPLASTY; SHOULDER DISLOCATION; SURGICAL ANATOMY; SURGICAL APPROACH; SURGICAL PATIENT; SURGICAL TECHNIQUE; TREATMENT CONTRAINDICATION; TREATMENT INDICATION; TREATMENT PLANNING;

EID: 10144232119     PISSN: 15239896     EISSN: None     Source Type: Journal    
DOI: 10.1097/00132589-200412000-00001     Document Type: Article
Times cited : (6)

References (20)
  • 1
    • 0028092012 scopus 로고
    • Arthroplasty and acute shoulder trauma: Reasons for success and failure
    • Compito CA, Self EB, Bigliani LU. Arthroplasty and acute shoulder trauma: reasons for success and failure. Clin Orthop. 1994;307:27-36.
    • (1994) Clin Orthop , vol.307 , pp. 27-36
    • Compito, C.A.1    Self, E.B.2    Bigliani, L.U.3
  • 2
    • 0347579834 scopus 로고    scopus 로고
    • Prognostic factors in prosthetic replacement for acute proximal humerus fractures
    • Demirhan M, Kilicoglu O, Altinel L, et al. Prognostic factors in prosthetic replacement for acute proximal humerus fractures. J Orthop Trauma. 2003;17:181-189.
    • (2003) J Orthop Trauma , vol.17 , pp. 181-189
    • Demirhan, M.1    Kilicoglu, O.2    Altinel, L.3
  • 3
    • 0029262273 scopus 로고
    • Functional outcome after humeral head replacement for acute three- and four-part proximal humeral fractures
    • Goldman RT, Koval KJ, Cuomo F, et al. Functional outcome after humeral head replacement for acute three- and four-part proximal humeral fractures. J Shoulder Elbow Surg. 1995;4:81-86.
    • (1995) J Shoulder Elbow Surg , vol.4 , pp. 81-86
    • Goldman, R.T.1    Koval, K.J.2    Cuomo, F.3
  • 4
    • 0027243468 scopus 로고
    • Acute prosthetic replacement for severe fractures of the proximal humerus
    • Hawkins RJ, Switlyk P. Acute prosthetic replacement for severe fractures of the proximal humerus. Clin Orthop. 1993;289:156-160.
    • (1993) Clin Orthop , vol.289 , pp. 156-160
    • Hawkins, R.J.1    Switlyk, P.2
  • 5
    • 0026737342 scopus 로고
    • Modular hemiarthroplasty for fractures of the proximal part of the humerus
    • Moeckel BH, Dines DM, Warren RF, et al. Modular hemiarthroplasty for fractures of the proximal part of the humerus. J Bone Joint Surg Am. 1992;74A:884-889.
    • (1992) J Bone Joint Surg Am , vol.74 A , pp. 884-889
    • Moeckel, B.H.1    Dines, D.M.2    Warren, R.F.3
  • 6
    • 0034324706 scopus 로고    scopus 로고
    • Displaced three- and four-part proximal humerus fractures: Evaluation and management
    • Naranja J, Iannotti JP. Displaced three- and four-part proximal humerus fractures: evaluation and management. J Am Acad Orthop Surg. 2000;8:373-382.
    • (2000) J Am Acad Orthop Surg , vol.8 , pp. 373-382
    • Naranja, J.1    Iannotti, J.P.2
  • 7
    • 0038124329 scopus 로고    scopus 로고
    • Primary hemiarthroplasty for treatment of proximal humeral fractures
    • Robinson CM, Page RS, Hill RMF, et al. Primary hemiarthroplasty for treatment of proximal humeral fractures. J Bone Joint Surg Am. 2003;85A:1215-1223.
    • (2003) J Bone Joint Surg Am , vol.85 A , pp. 1215-1223
    • Robinson, C.M.1    Page, R.S.2    Hill, R.M.F.3
  • 8
    • 0020513832 scopus 로고
    • Prosthetic arthroplasty for fractures and fracture-dislocations of the proximal humerus
    • Tanner MW, Cofield RH. Prosthetic arthroplasty for fractures and fracture-dislocations of the proximal humerus. Clin Orthop. 1983;179:116-128.
    • (1983) Clin Orthop , vol.179 , pp. 116-128
    • Tanner, M.W.1    Cofield, R.H.2
  • 9
    • 0030817994 scopus 로고    scopus 로고
    • Hemiarthroplasty in the treatment of comminuted intraarticular fractures of the proximal humerus
    • Dimakopoulos P, Potamitis N, Lambiris E. Hemiarthroplasty in the treatment of comminuted intraarticular fractures of the proximal humerus. Clin Orthop. 1997;341:7-11.
    • (1997) Clin Orthop , vol.341 , pp. 7-11
    • Dimakopoulos, P.1    Potamitis, N.2    Lambiris, E.3
  • 10
    • 10144260367 scopus 로고    scopus 로고
    • Hemiarthroplasty for complex four-part fracture of the proximal humerus: Technical considerations and surgical technique
    • Dines DM, Tuckman DV, Dines J. Hemiarthroplasty for complex four-part fracture of the proximal humerus: technical considerations and surgical technique. U Penn Ortho J. 2002;15:29-36.
    • (2002) U Penn Ortho J , vol.15 , pp. 29-36
    • Dines, D.M.1    Tuckman, D.V.2    Dines, J.3
  • 11
    • 0035406080 scopus 로고    scopus 로고
    • Biomechanical effects of malposition of tuberosity fragments on the humeral prosthetic reconstruction for four-part proximal humerus fractures
    • Frankle MA, Greenwald DP, Markee BA, et al. Biomechanical effects of malposition of tuberosity fragments on the humeral prosthetic reconstruction for four-part proximal humerus fractures. J Shoulder Elbow Surg. 2001;10:321-326.
    • (2001) J Shoulder Elbow Surg , vol.10 , pp. 321-326
    • Frankle, M.A.1    Greenwald, D.P.2    Markee, B.A.3
  • 12
    • 0029934721 scopus 로고    scopus 로고
    • Surgical treatment of complex fracture of the proximal humerus
    • Ko JY, Yamamoto R. Surgical treatment of complex fracture of the proximal humerus. Clin Orthop. 1996;327:225-237.
    • (1996) Clin Orthop , vol.327 , pp. 225-237
    • Ko, J.Y.1    Yamamoto, R.2
  • 13
    • 0346849974 scopus 로고    scopus 로고
    • Outcomes of hemiarthroplasty for fractures of the proximal humerus
    • Mighell MA, Kolm GP, Collinge CA, et al. Outcomes of hemiarthroplasty for fractures of the proximal humerus. J Shoulder Elbow Surg. 2003;12:569-577.
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 569-577
    • Mighell, M.A.1    Kolm, G.P.2    Collinge, C.A.3
  • 14
    • 0032971228 scopus 로고    scopus 로고
    • Geometric analysis of commonly used prosthetic systems for proximal humeral replacement
    • Pearl MI, Kurutz S. Geometric analysis of commonly used prosthetic systems for proximal humeral replacement. J Bone Joint Surg Am. 1999;81A:660-671.
    • (1999) J Bone Joint Surg Am , vol.81 A , pp. 660-671
    • Pearl, M.I.1    Kurutz, S.2
  • 15
    • 0031880983 scopus 로고    scopus 로고
    • Assessment and management of three- and four-part proximal humerus fractures
    • Rees J, Hicks J, Ribbans W. Assessment and management of three- and four-part proximal humerus fractures. Clin Orthop. 1998;353:18-29.
    • (1998) Clin Orthop , vol.353 , pp. 18-29
    • Rees, J.1    Hicks, J.2    Ribbans, W.3
  • 16
    • 0028100016 scopus 로고
    • Modular shoulder hemiarthroplasty for acute fractures: Surgical considerations
    • Dines DM, Warren RF. Modular shoulder hemiarthroplasty for acute fractures: surgical considerations. Clin Orthop. 1994;307:18-26.
    • (1994) Clin Orthop , vol.307 , pp. 18-26
    • Dines, D.M.1    Warren, R.F.2
  • 17
    • 0032021178 scopus 로고    scopus 로고
    • The use of the bicipital groove for alignment of the humeral stem in shoulder arthroplasty
    • Kummer FJ, Perkins R, Zuckerman JD. The use of the bicipital groove for alignment of the humeral stem in shoulder arthroplasty. J Shoulder Elbow Surg. 1998;7:144-147.
    • (1998) J Shoulder Elbow Surg , vol.7 , pp. 144-147
    • Kummer, F.J.1    Perkins, R.2    Zuckerman, J.D.3
  • 18
    • 0036633769 scopus 로고    scopus 로고
    • Analysis of the bicipital groove as a landmark for humeral head replacement
    • Itamura J, Dietrick T, Roidis N, et al. Analysis of the bicipital groove as a landmark for humeral head replacement. J Shoulder Elbow Surg. 2002;11:322-326.
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 322-326
    • Itamura, J.1    Dietrick, T.2    Roidis, N.3
  • 19
    • 10144228888 scopus 로고    scopus 로고
    • A prospective multicenter outcome study of shoulder arthroplasty for the treatment of proximal humeral fractures
    • Orlando, Florida
    • Boileau P, Walch G, Romeo A, et al. A prospective multicenter outcome study of shoulder arthroplasty for the treatment of proximal humeral fractures. Presented at the AAOS Orlando 2000 Open Meeting of the American Shoulder and Elbow Surgeons, Orlando, Florida, 2000.
    • (2000) AAOS Orlando 2000 Open Meeting of the American Shoulder and Elbow Surgeons
    • Boileau, P.1    Walch, G.2    Romeo, A.3
  • 20
    • 0036719875 scopus 로고    scopus 로고
    • Stability of tuberosity reattachment in proximal humeral hemiarthroplasty
    • Frankle MA, Ondrovic LE, Markee BA, et al. Stability of tuberosity reattachment in proximal humeral hemiarthroplasty. J Shoulder Elbow Surg. 2002;11:413-420.
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 413-420
    • Frankle, M.A.1    Ondrovic, L.E.2    Markee, B.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.