메뉴 건너뛰기




Volumn 77, Issue 923, 2004, Pages 950-952

Technical note: A comparison of antiscatter grids for digital radiography

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM;

EID: 10044296987     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/21117919     Document Type: Article
Times cited : (10)

References (6)
  • 1
    • 0027492855 scopus 로고
    • Selection of anti-scatter grids for different imaging tasks: The advantage of low atomic number cover and interspace materials
    • Sandborg M, Dance DR, Alm Carlsson G, Persliden J. Selection of anti-scatter grids for different imaging tasks: the advantage of low atomic number cover and interspace materials. Br J Radiol 1993;66:1151-63.
    • (1993) Br. J. Radiol. , vol.66 , pp. 1151-1163
    • Sandborg, M.1    Dance, D.R.2    Alm Carlsson, G.3    Persliden, J.4
  • 2
    • 0027453935 scopus 로고
    • Monte Carlo study of grid performance in diagnostic radiology: Factors which affect the selection of tube potential and grid ratio
    • Sandborg M, Dance DR, Alm Carlsson G, Persliden J. Monte Carlo study of grid performance in diagnostic radiology: factors which affect the selection of tube potential and grid ratio. Br J Radiol 1993;66:1164-76.
    • (1993) Br. J. Radiol. , vol.66 , pp. 1164-1176
    • Sandborg, M.1    Dance, D.R.2    Alm Carlsson, G.3    Persliden, J.4
  • 3
    • 0028057799 scopus 로고
    • Monte Carlo study of grid performance in diagnostic radiology: Task dependent optimization for screen film imaging
    • Sandborg M, Dance DR, Alm Carlsson G, Persliden J. Monte Carlo study of grid performance in diagnostic radiology: task dependent optimization for screen film imaging. Br J Radiol 1994;67:76-85.
    • (1994) Br. J. Radiol. , vol.67 , pp. 76-85
    • Sandborg, M.1    Dance, D.R.2    Alm Carlsson, G.3    Persliden, J.4
  • 5
    • 0020680912 scopus 로고
    • The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology
    • Chan H-P, Doi K. The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology. Phys Med Biol 1983;28:109-29.
    • (1983) Phys. Med. Biol. , vol.28 , pp. 109-129
    • Chan, H.-P.1    Doi, K.2
  • 6
    • 0025179070 scopus 로고
    • Studies of performance of antiscatter grids in digital radiography: Effect on signal-to-noise ratio
    • Chan H-P, Lam KL, Wu Y. Studies of performance of antiscatter grids in digital radiography: effect on signal-to-noise ratio. Med Phys 1990;17:655-64.
    • (1990) Med. Phys. , vol.17 , pp. 655-664
    • Chan, H.-P.1    Lam, K.L.2    Wu, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.