메뉴 건너뛰기




Volumn 5475, Issue , 2004, Pages 48-55

Optical coherence tomography device for paper characterization

Author keywords

Optical coherence tomography; Paper; Profilometry; Structure imaging

Indexed keywords

LOW COHERENCE INTERFEROMETRY (LCI); OPTICAL COHERENCE TOMOGRAPHY; STRUCTURE IMAGING; SURFACE PARAMETERS;

EID: 10044286110     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.568573     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 1
    • 10044247904 scopus 로고    scopus 로고
    • Sorption abilities of paper and board from recycled fibers
    • V.Z. Rutar, M. Letnar, "Sorption Abilities of Paper and Board from Recycled Fibers", Cost action E11, 9 p, 2001.
    • (2001) Cost Action , vol.E11
    • Rutar, V.Z.1    Letnar, M.2
  • 3
    • 0011380667 scopus 로고    scopus 로고
    • Licentiate Thesis, Kungliga Tekniska Hogskola, Royal Institute of Technologys
    • M. Haggkvist, "Porous structure in paper studied by NMR", Licentiate Thesis, Kungliga Tekniska Hogskola, Royal Institute of Technologys, 1-33, 1999.
    • (1999) Porous Structure in Paper Studied by NMR , pp. 1-33
    • Haggkvist, M.1
  • 5
    • 0033327503 scopus 로고    scopus 로고
    • Optical coherence tomography (OCT): A review
    • J. M. Schmitt, "Optical coherence tomography (OCT): a review", IEEE J. Select. Top. Quant. Electron. 5, 1205-1215, 1999.
    • (1999) IEEE J. Select. Top. Quant. Electron. , vol.5 , pp. 1205-1215
    • Schmitt, J.M.1
  • 8
    • 0000142682 scopus 로고
    • Measurement of corneal thickness by low-coherence interferometry
    • C. K. Hitzenberger, "Measurement of corneal thickness by low-coherence interferometry", Appl. Optics 31(31), 6637-6642, 1992.
    • (1992) Appl. Optics , vol.31 , Issue.31 , pp. 6637-6642
    • Hitzenberger, C.K.1
  • 9
    • 65949113578 scopus 로고
    • Low-coherence optical tomography in turbid tissue: Theoretical analysis
    • Y. Pan, R. Birngruber, J. Rosperich, and R. Engelhart, "Low-coherence optical tomography in turbid tissue: theoretical analysis", Appl. Opt. 34, 6564-6574, 1995.
    • (1995) Appl. Opt. , vol.34 , pp. 6564-6574
    • Pan, Y.1    Birngruber, R.2    Rosperich, J.3    Engelhart, R.4
  • 10
    • 0000832793 scopus 로고    scopus 로고
    • Optical coherence tomography
    • A. F. Fercher, "Optical coherence tomography", J. Biomed. Opt. 1, 157-173, 1996.
    • (1996) J. Biomed. Opt. , vol.1 , pp. 157-173
    • Fercher, A.F.1
  • 12
    • 10044292461 scopus 로고    scopus 로고
    • Enhancing the OCT images by the low coherence fringe envelope deconvolution method
    • accepted
    • J. Hast, I. Gurov, E. Alarousu, A. Zakharov, R. Myllylä, "Enhancing the OCT images by the low coherence fringe envelope deconvolution method", Proc. SPIE, 2003. (accepted)
    • (2003) Proc. SPIE
    • Hast, J.1    Gurov, I.2    Alarousu, E.3    Zakharov, A.4    Myllylä, R.5
  • 13
    • 0344900033 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of internal random structure of wood fiber tissue
    • I. Gurov, E. Alarousu, J. Hast, R. Myllylä, T. Prykäri, A. Zakharov, "Optical coherence tomography evaluation of internal random structure of wood fiber tissue", Proc. of SPIE 5132, 149-160, 2003.
    • (2003) Proc. of SPIE , vol.5132 , pp. 149-160
    • Gurov, I.1    Alarousu, E.2    Hast, J.3    Myllylä, R.4    Prykäri, T.5    Zakharov, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.