메뉴 건너뛰기




Volumn 42, Issue 1, 2004, Pages 13-30

Arterial and Central Venous Pressure Monitoring

Author keywords

[No Author keywords available]

Indexed keywords

AIR EMBOLISM; ARTERIAL PRESSURE; ARTERY CATHETERIZATION; BRAIN PERFUSION; BREATHING PATTERN; CENTRAL VENOUS PRESSURE; ELECTROCARDIOGRAM; EMBOLISM; ENDOCARDITIS; HEART ARRHYTHMIA; HEART PRELOAD; HEMATOMA; HEMATOTHORAX; HUMAN; ISCHEMIA; LUNG EMBOLISM; MEAN ARTERIAL PRESSURE; NERVE INJURY; NON INVASIVE MEASUREMENT; PATIENT MONITORING; PNEUMOTHORAX; PRESSURE MEASUREMENT; PRESSURE TRANSDUCER; PRIORITY JOURNAL; PULSE WAVE; REVIEW; SEPSIS; SYSTOLIC BLOOD PRESSURE; THORAX PRESSURE; TREATMENT INDICATION; VEIN THROMBOSIS;

EID: 0942268824     PISSN: 00205907     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004311-200404210-00004     Document Type: Review
Times cited : (55)

References (25)
  • 1
    • 0001823617 scopus 로고
    • The physiology and clinical use of the sphygmograph
    • Mahomed FA. The physiology and clinical use of the sphygmograph. Med Times Gazette. 1872;1:128-130.
    • (1872) Med Times Gazette , vol.1 , pp. 128-130
    • Mahomed, F.A.1
  • 2
    • 0019182236 scopus 로고
    • The dynamic responses of liquid-filled catheter systems for direct measurements of blood pressure
    • Shinozaki T, Deane RS, Mazuzan JE. The dynamic responses of liquid-filled catheter systems for direct measurements of blood pressure. Anesthesiology. 1980;53:498-504.
    • (1980) Anesthesiology , vol.53 , pp. 498-504
    • Shinozaki, T.1    Deane, R.S.2    Mazuzan, J.E.3
  • 3
    • 0020636555 scopus 로고
    • Pulmonary artery occlusion pressure: Clinical physiology, measurement, and interpretation
    • O'Quin R, Marini JJ. Pulmonary artery occlusion pressure: clinical physiology, measurement, and interpretation. Am Rev Respir Dis. 1983;128:319-326.
    • (1983) Am Rev Respir Dis , vol.128 , pp. 319-326
    • O'Quin, R.1    Marini, J.J.2
  • 4
    • 0019523842 scopus 로고
    • Direct blood pressure measurement: Dynamic response requirements
    • Gardner RM. Direct blood pressure measurement: dynamic response requirements. Anesthesiology. 1981;54:227-236.
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 5
    • 0000097581 scopus 로고    scopus 로고
    • Cardiovascular monitoring
    • Miller RD, ed. Philadelphia: WB Saunders Co.
    • Mark JB, Slaughter TF, Reves JG. Cardiovascular monitoring. In: Miller RD, ed. Anesthesia, 5th ed. Philadelphia: WB Saunders Co; 2000:1117-1206.
    • (2000) Anesthesia, 5th Ed. , pp. 1117-1206
    • Mark, J.B.1    Slaughter, T.F.2    Reves, J.G.3
  • 6
    • 0026690056 scopus 로고
    • The fast flush test measures the dynamic response of the entire blood pressure monitoring system
    • Kleinman B, Powell S, Kumar P, et al. The fast flush test measures the dynamic response of the entire blood pressure monitoring system. Anesthesiology. 1992;77:1215-1220.
    • (1992) Anesthesiology , vol.77 , pp. 1215-1220
    • Kleinman, B.1    Powell, S.2    Kumar, P.3
  • 7
    • 0030110761 scopus 로고    scopus 로고
    • Equivalence of the fast flush and square wave testing of blood pressure monitoring systems
    • Kleinman B, Powell S, Gardner RM. Equivalence of the fast flush and square wave testing of blood pressure monitoring systems. J Clin Monit Comput. 1996;12:149-154.
    • (1996) J Clin Monit Comput , vol.12 , pp. 149-154
    • Kleinman, B.1    Powell, S.2    Gardner, R.M.3
  • 8
    • 0023834947 scopus 로고
    • Technical note: Estimation of the damping coefficient of fluid-filled, catheter-transducer pressure-measuring systems
    • Geddes LA, Bourland JD. Technical note: estimation of the damping coefficient of fluid-filled, catheter-transducer pressure-measuring systems. J Clin Engineering. 1988;13:59-62.
    • (1988) J Clin Engineering , vol.13 , pp. 59-62
    • Geddes, L.A.1    Bourland, J.D.2
  • 9
    • 0023786403 scopus 로고
    • Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method
    • Schwid HA. Frequency response evaluation of radial artery catheter-manometer systems: sinusoidal frequency analysis versus flush method. J Clin Monit Comput. 1988;4:181-185.
    • (1988) J Clin Monit Comput , vol.4 , pp. 181-185
    • Schwid, H.A.1
  • 10
    • 0029100145 scopus 로고
    • Anatomically and physiologically based reference level for measurement of intracardiac pressures
    • Courtois M, Fattal PG, Kovacs SJ, et al. Anatomically and physiologically based reference level for measurement of intracardiac pressures. Circulation. 1995;92:1994-2000.
    • (1995) Circulation , vol.92 , pp. 1994-2000
    • Courtois, M.1    Fattal, P.G.2    Kovacs, S.J.3
  • 11
    • 0040561188 scopus 로고    scopus 로고
    • Technical requirements for direct blood pressure measurement
    • Mark JB, ed. New York: Churchill Livingstone
    • Mark JB. Technical requirements for direct blood pressure measurement. In: Mark JB, ed. Atlas of Cardiovascular Monitoring. New York: Churchill Livingstone; 1998:99-126.
    • (1998) Atlas of Cardiovascular Monitoring , pp. 99-126
    • Mark, J.B.1
  • 12
    • 0041515834 scopus 로고
    • Radial artery cannulation in 1,000 patients: Precautions and complications
    • Mandel MA, Dauchot PJ. Radial artery cannulation in 1,000 patients: precautions and complications. J Hand Surg. 1977;2:482-485.
    • (1977) J Hand Surg , vol.2 , pp. 482-485
    • Mandel, M.A.1    Dauchot, P.J.2
  • 13
    • 0027673652 scopus 로고
    • Problems associated with vascular access: An analysis of 2000 incident reports
    • Singleton RJ, Webb RK, Ludbrook GL, et al. Problems associated with vascular access: an analysis of 2000 incident reports. Anaesth Intensive Care. 1993;21:664-669.
    • (1993) Anaesth Intensive Care , vol.21 , pp. 664-669
    • Singleton, R.J.1    Webb, R.K.2    Ludbrook, G.L.3
  • 14
    • 0021347103 scopus 로고
    • Wave reflections and the arterial pulse
    • O'Rourke MF, Yaginuma T. Wave reflections and the arterial pulse. Arch Intern Med. 1984;144:366-371.
    • (1984) Arch Intern Med , vol.144 , pp. 366-371
    • O'Rourke, M.F.1    Yaginuma, T.2
  • 15
    • 0028034329 scopus 로고
    • Measuring hypertensive cardiovascular risk: The vascular overload concept
    • Franklin SS, Weber MA. Measuring hypertensive cardiovascular risk: the vascular overload concept. Am Heart J. 1994;128:793-803.
    • (1994) Am Heart J , vol.128 , pp. 793-803
    • Franklin, S.S.1    Weber, M.A.2
  • 16
    • 0023605206 scopus 로고    scopus 로고
    • Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage
    • Perel A. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 2003;67:498-502.
    • (2003) Anesthesiology , vol.67 , pp. 498-502
    • Perel, A.1
  • 17
    • 0028906057 scopus 로고
    • The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation
    • Rooke GA, Schwid HA, Shapira Y. The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation. Anesth Analg. 1995;80:925-932.
    • (1995) Anesth Analg , vol.80 , pp. 925-932
    • Rooke, G.A.1    Schwid, H.A.2    Shapira, Y.3
  • 18
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121:2000-2008.
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 19
    • 0029786702 scopus 로고    scopus 로고
    • Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform
    • Pizov R, Cohen M, Weiss Y, et al. Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform. Crit Care Med. 1996;24:1381-1387.
    • (1996) Crit Care Med , vol.24 , pp. 1381-1387
    • Pizov, R.1    Cohen, M.2    Weiss, Y.3
  • 20
    • 0025859167 scopus 로고
    • Expert panel: The use of the pulmonary artery catheter
    • Bennett D, Boldt J, Brochard L. Expert panel: the use of the pulmonary artery catheter. Intensive Care Med. 1991;17:I-VIII.
    • (1991) Intensive Care Med , vol.17
    • Bennett, D.1    Boldt, J.2    Brochard, L.3
  • 21
    • 0035827890 scopus 로고    scopus 로고
    • Complication of femoral and subclavian venous catheterization in critically ill patients
    • Merrer J, De Jnoghe B, Golliot F, et al. Complication of femoral and subclavian venous catheterization in critically ill patients. JAMA. 2001;286:700-707.
    • (2001) JAMA , vol.286 , pp. 700-707
    • Merrer, J.1    De Jnoghe, B.2    Golliot, F.3
  • 22
    • 0037456765 scopus 로고    scopus 로고
    • Preventing complications of central venous catheterization
    • McGee DC. Preventing complications of central venous catheterization. N Engl J Med. 2003;348:1123-1133.
    • (2003) N Engl J Med , vol.348 , pp. 1123-1133
    • McGee, D.C.1
  • 23
    • 84941817891 scopus 로고
    • Central vein catheterization: Failure and complication rates by three percutaneous approaches
    • Sznaider JI, Zveibil FR, Bitterman H, et al. Central vein catheterization: failure and complication rates by three percutaneous approaches. Arch Intern Med. 1986;146:259-261.
    • (1986) Arch Intern Med , vol.146 , pp. 259-261
    • Sznaider, J.I.1    Zveibil, F.R.2    Bitterman, H.3
  • 24
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
    • Randolph AG, Cook DJ, Gonzales CA, et al. Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med. 1996;24:2053-2058.
    • (1996) Crit Care Med , vol.24 , pp. 2053-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.