메뉴 건너뛰기




Volumn 42, Issue 1, 2004, Pages 31-58

Hemodynamic Assessment of the Critically Ill Patient

Author keywords

[No Author keywords available]

Indexed keywords

AIR EMBOLISM; ARTERY CATHETER; ARTERY CATHETERIZATION; ARTERY INJURY; ARTERY RUPTURE; BLEEDING; CAPNOGRAPHY; CARBON DIOXIDE BREATHING; CENTRAL VENOUS CATHETERIZATION; COMPLETE HEART BLOCK; CRITICAL ILLNESS; DATA ANALYSIS; DOPPLER FLOWMETRY; GASTRIC TONOMETRY; HEART ARRHYTHMIA; HEART LEFT VENTRICLE ENDDIASTOLIC PRESSURE; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART OUTPUT; HEART RIGHT BUNDLE BRANCH BLOCK; HEMODYNAMIC MONITORING; HEMODYNAMICS; HUMAN; IMPEDANCE; LUNG INFARCTION; MIXED VENOUS OXYGEN SATURATION CATHETER; MORTALITY; NEUROPATHY; OXYGEN SATURATION; PATIENT MONITORING; POSITIVE END EXPIRATORY PRESSURE; PRESSURE MEASUREMENT; PRIORITY JOURNAL; PULMONARY ARTERY; PULSE CONTOUR ANALYSIS; PULSE WAVE; REVIEW; SEPSIS; SIGNAL NOISE RATIO; SUBLINGUAL CAPNOMETRY; THERMODILUTION; THORACIC BIOIMPEDANCE; THROMBOPHLEBITIS; THROMBUS; TONOMETRY; VEIN THROMBOSIS;

EID: 0942268823     PISSN: 00205907     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004311-200404210-00005     Document Type: Review
Times cited : (12)

References (72)
  • 1
    • 0031802663 scopus 로고    scopus 로고
    • Diagnostic validity of pulmonary artery catheterization for residents at an intensive care unit
    • Staudinger T, Gotfried J, Laczika K, et al. Diagnostic validity of pulmonary artery catheterization for residents at an intensive care unit. J Trauma. 1998;44:902-906.
    • (1998) J Trauma , vol.44 , pp. 902-906
    • Staudinger, T.1    Gotfried, J.2    Laczika, K.3
  • 2
    • 0025825991 scopus 로고
    • Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU
    • Steingrub JS, Celoria G, Vickers-Lahti M, et al. Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU. Chest. 1991;99:1451-1455.
    • (1991) Chest , vol.99 , pp. 1451-1455
    • Steingrub, J.S.1    Celoria, G.2    Vickers-Lahti, M.3
  • 3
    • 0011210988 scopus 로고
    • Central venous pressure monitoring is an outmoded procedure of limited practical value
    • Ingelfinger FJ, Ebert RV, Finland M, et al., eds. Philadelphia: WB Saunders
    • Swan HJC. Central venous pressure monitoring is an outmoded procedure of limited practical value. In: Ingelfinger FJ, Ebert RV, Finland M, et al., eds. Controversies in Internal Medicine. Philadelphia: WB Saunders; 1974:185.
    • (1974) Controversies in Internal Medicine , pp. 185
    • Swan, H.J.C.1
  • 4
    • 0015236415 scopus 로고
    • Filling pressures in right and left sides of the heart in acute myocardial infarction. A reappraisal of central-venous-pressure monitoring
    • Forrester JS, Diamond G, McHugh TJ, et al. Filling pressures in right and left sides of the heart in acute myocardial infarction. A reappraisal of central-venous-pressure monitoring. N Engl J Med. 1971;285:190-193.
    • (1971) N Engl J Med , vol.285 , pp. 190-193
    • Forrester, J.S.1    Diamond, G.2    McHugh, T.J.3
  • 5
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients
    • Connors AF, Speroff T, Dawson NV, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA. 1996;276:889-897.
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors, A.F.1    Speroff, T.2    Dawson, N.V.3
  • 6
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary artery catheters in high risk surgical patients
    • Sandham JD, Hull RD, Brant RF, et al. A randomized, controlled trial of the use of pulmonary artery catheters in high risk surgical patients. N Engl J Med. 2003;348:5-14.
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 7
    • 0027499422 scopus 로고
    • A Report from the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization. Practice guidelines for pulmonary artery catheterization
    • A Report from the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization. Practice guidelines for pulmonary artery catheterization. Anesthesiology. 1993;78:380-394.
    • (1993) Anesthesiology , vol.78 , pp. 380-394
  • 8
    • 0030965778 scopus 로고    scopus 로고
    • Pulmonary Artery Catheterization Consensus Conference. Consensus Statement
    • Pulmonary Artery Catheterization Consensus Conference. Consensus Statement. Crit Care Med. 1997;25:910-935.
    • (1997) Crit Care Med , vol.25 , pp. 910-935
  • 9
    • 0025685462 scopus 로고
    • A multicenter study of physicians' knowledge of the pulmonary artery catheter
    • Pulmonary Artery Catheter Study Group
    • Iberti TJ, Fischer EP, Leibowitz AB, et al. A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group. JAMA. 1990;264:2928-2932.
    • (1990) JAMA , vol.264 , pp. 2928-2932
    • Iberti, T.J.1    Fischer, E.P.2    Leibowitz, A.B.3
  • 10
    • 0031034151 scopus 로고    scopus 로고
    • Intensive care physician's insufficient knowledge of right-heart catheterization at bedside: Time to act?
    • Gnaegi A, Feihl F, Perret C. Intensive care physician's insufficient knowledge of right-heart catheterization at bedside: time to act? Crit Care Med. 1997;25:213-220.
    • (1997) Crit Care Med , vol.25 , pp. 213-220
    • Gnaegi, A.1    Feihl, F.2    Perret, C.3
  • 11
    • 0027974196 scopus 로고
    • Assessment of critical care nurses' knowledge of pulmonary artery catheter
    • Iberti TJ, Dailey EK, Leibowitz AB, et al. Assessment of critical care nurses' knowledge of pulmonary artery catheter. Crit Care Med. 1994;22:1674-1678.
    • (1994) Crit Care Med , vol.22 , pp. 1674-1678
    • Iberti, T.J.1    Dailey, E.K.2    Leibowitz, A.B.3
  • 12
    • 0030833676 scopus 로고    scopus 로고
    • Society of Critical Care Medicine: Pulmonary artery catheter membership survey
    • Trottier SJ, Taylor RW. Society of Critical Care Medicine: pulmonary artery catheter membership survey. New Horizon. 1997;5:201-206.
    • (1997) New Horizon , vol.5 , pp. 201-206
    • Trottier, S.J.1    Taylor, R.W.2
  • 13
    • 0036270533 scopus 로고    scopus 로고
    • Pulmonary artery occlusion pressure estimation: How confident are we
    • Jacka MJ, Cohen MM, To T, et al. Pulmonary artery occlusion pressure estimation: how confident are we. Crit Care Med. 2002;30:1197-1203.
    • (2002) Crit Care Med , vol.30 , pp. 1197-1203
    • Jacka, M.J.1    Cohen, M.M.2    To, T.3
  • 14
    • 0034679103 scopus 로고    scopus 로고
    • Pulmonary artery catheterization and clinical outcomes
    • National Heart, Lung and Blood Institute and Food and Drug Administration Workshop
    • Bernard GR, Sopko G, Cerra F, et al. Pulmonary artery catheterization and clinical outcomes. National Heart, Lung and Blood Institute and Food and Drug Administration Workshop. JAMA. 2000;283:2568-2572.
    • (2000) JAMA , vol.283 , pp. 2568-2572
    • Bernard, G.R.1    Sopko, G.2    Cerra, F.3
  • 15
    • 0019523842 scopus 로고
    • Direct blood pressure measurement-dynamic response requirements
    • Gardner RM. Direct blood pressure measurement-dynamic response requirements. Anesthesiology. 1981;54:227-236.
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 16
    • 0022622142 scopus 로고
    • Measurement of effective pulmonary capillary pressure using the pressure profile after artery occlusion
    • Cope DK, Allison RC, Permentier JL, et al. Measurement of effective pulmonary capillary pressure using the pressure profile after artery occlusion. Crit Care Med. 1986;14:16-22.
    • (1986) Crit Care Med , vol.14 , pp. 16-22
    • Cope, D.K.1    Allison, R.C.2    Permentier, J.L.3
  • 17
    • 0037249717 scopus 로고    scopus 로고
    • Overestimation of pulmonary artery occlusion pressure in pulmonary hypertension due to partial occlusion
    • Leatherman JW, Shapiro RS. Overestimation of pulmonary artery occlusion pressure in pulmonary hypertension due to partial occlusion. Crit Care Med. 2003;31:93-97.
    • (2003) Crit Care Med , vol.31 , pp. 93-97
    • Leatherman, J.W.1    Shapiro, R.S.2
  • 18
    • 0022263624 scopus 로고
    • Obtaining meaningful data from the Swan-Ganz catheter
    • Marini JJ. Obtaining meaningful data from the Swan-Ganz catheter. Respir Care. 1985;30:572-585.
    • (1985) Respir Care , vol.30 , pp. 572-585
    • Marini, J.J.1
  • 19
    • 78651150557 scopus 로고
    • Distribution of blood flow in isolated lung; relation to vascular and alveolar pressures
    • West JB, Dollery CT, Naimark A. Distribution of blood flow in isolated lung; relation to vascular and alveolar pressures. J Appl Physiol. 1964;19:713.
    • (1964) J Appl Physiol , vol.19 , pp. 713
    • West, J.B.1    Dollery, C.T.2    Naimark, A.3
  • 20
    • 0022740605 scopus 로고
    • Acute lung injury. Hemodynamic monitoring with the pulmonary artery catheter
    • Marini JJ. Acute lung injury. Hemodynamic monitoring with the pulmonary artery catheter. Crit Care Clin. 1986;2:551-572.
    • (1986) Crit Care Clin , vol.2 , pp. 551-572
    • Marini, J.J.1
  • 21
    • 0022378614 scopus 로고
    • Invasive monitoring and support of the circulation
    • Donovan KD. Invasive monitoring and support of the circulation. Clin Anesthesiol. 1985;3:909-953.
    • (1985) Clin Anesthesiol , vol.3 , pp. 909-953
    • Donovan, K.D.1
  • 22
    • 0014880409 scopus 로고
    • Pulmonary artery and left heart end-diastolic pressure relations
    • Herbert WH. Pulmonary artery and left heart end-diastolic pressure relations. Br Heart J. 1970;32:774-778.
    • (1970) Br Heart J , vol.32 , pp. 774-778
    • Herbert, W.H.1
  • 23
    • 0019964020 scopus 로고
    • Estimation of transmural cardiac pressures during ventilation with PEEP
    • Marini JJ, O'Quin R, Culver BH, et al. Estimation of transmural cardiac pressures during ventilation with PEEP. J Appl Physiol. 1982;53:384-391.
    • (1982) J Appl Physiol , vol.53 , pp. 384-391
    • Marini, J.J.1    O'Quin, R.2    Culver, B.H.3
  • 24
    • 0019989011 scopus 로고
    • Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: The auto-PEEP effect
    • Pepe PE, Marini JJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. Am Rev Respir Dis. 1982;126:166-170.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 166-170
    • Pepe, P.E.1    Marini, J.J.2
  • 25
    • 0019350064 scopus 로고
    • Influence of positive end-expiratory pressure on left ventricular performance
    • Jardin F, Farcot JC, Boisante L, et al. Influence of positive end-expiratory pressure on left ventricular performance. N Engl J Med. 1981;304:387-392.
    • (1981) N Engl J Med , vol.304 , pp. 387-392
    • Jardin, F.1    Farcot, J.C.2    Boisante, L.3
  • 26
    • 0018699698 scopus 로고
    • PEEP-induced discrepancy between pulmonary arterial wedge pressure and left atrial pressure: The effects of controlled vs. spontaneous ventilation and compliant vs. noncompliant lungs in the dog
    • Berryhill RE, Benumof JL. PEEP-induced discrepancy between pulmonary arterial wedge pressure and left atrial pressure: the effects of controlled vs. spontaneous ventilation and compliant vs. noncompliant lungs in the dog. Anesthesiology. 1979;51:303-308.
    • (1979) Anesthesiology , vol.51 , pp. 303-308
    • Berryhill, R.E.1    Benumof, J.L.2
  • 27
    • 0022652548 scopus 로고
    • Improved oxygenation and lower peak airway pressure in severe adult respiratory distress syndrome. Treatment with inverse ratio ventilation
    • Gurevitch MJ, Van Dyke J, Young ES, et al. Improved oxygenation and lower peak airway pressure in severe adult respiratory distress syndrome. Treatment with inverse ratio ventilation. Chest. 1986;89:211-213.
    • (1986) Chest , vol.89 , pp. 211-213
    • Gurevitch, M.J.1    Van Dyke, J.2    Young, E.S.3
  • 28
    • 0021273264 scopus 로고
    • A review of pulmonary artery catheterization in 6,245 patients
    • Shah KB, Rao TK, Laughlin S, et al. A review of pulmonary artery catheterization in 6,245 patients. Anesthesiology. 1984;61:271-275.
    • (1984) Anesthesiology , vol.61 , pp. 271-275
    • Shah, K.B.1    Rao, T.K.2    Laughlin, S.3
  • 29
    • 0014852678 scopus 로고
    • Transient phrenic-nerve paralysis following subclavian venipuncture
    • Obel IW. Transient phrenic-nerve paralysis following subclavian venipuncture. Anesthesiology. 1970;33:369-370.
    • (1970) Anesthesiology , vol.33 , pp. 369-370
    • Obel, I.W.1
  • 30
    • 0019870874 scopus 로고
    • Heparin bonding reduces thrombogenicity of pulmonary-artery catheters
    • Hoar PF, Wilson RM, Mangano DT II, et al. Heparin bonding reduces thrombogenicity of pulmonary-artery catheters. N Engl J Med. 1981;305:993-995.
    • (1981) N Engl J Med , vol.305 , pp. 993-995
    • Hoar, P.F.1    Wilson, R.M.2    Mangano II, D.T.3
  • 31
    • 0026746473 scopus 로고
    • A controlled trial of scheduled replacement of central venous and pulmonary-artery catheters
    • Cobb DK, High KP, Sawyer RG, et al. A controlled trial of scheduled replacement of central venous and pulmonary-artery catheters. N Engl J Med. 1992;327:1062-1068.
    • (1992) N Engl J Med , vol.327 , pp. 1062-1068
    • Cobb, D.K.1    High, K.P.2    Sawyer, R.G.3
  • 32
    • 0037456765 scopus 로고    scopus 로고
    • Preventing complications of central venous catheterization
    • McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003;348:1123-1133.
    • (2003) N Engl J Med , vol.348 , pp. 1123-1133
    • McGee, D.C.1    Gould, M.K.2
  • 33
    • 0003183191 scopus 로고    scopus 로고
    • Guidelines for prevention of intravascular-related infections
    • Centers for Disease Central and Prevention. Guidelines for prevention of intravascular-related infections. MMWR Morb Mortal Wkly Rep. 2002;51:1-36.
    • (2002) MMWR Morb Mortal Wkly Rep , vol.51 , pp. 1-36
  • 34
    • 0019452928 scopus 로고
    • Catheter-induced pulmonary artery perforation. Mechanisms, management, and modifications
    • Barash PG, Nardi D, Hammond G, et al. Catheter-induced pulmonary artery perforation. Mechanisms, management, and modifications. J Thorac Cardiovasc Surg. 1981;82:5-12.
    • (1981) J Thorac Cardiovasc Surg , vol.82 , pp. 5-12
    • Barash, P.G.1    Nardi, D.2    Hammond, G.3
  • 35
    • 0015041424 scopus 로고
    • A new technique for measurement of cardiac output by thermodilution in man
    • Ganz W, Donoso R, Marcus HS, et al. A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol. 1971;27:392-396.
    • (1971) Am J Cardiol , vol.27 , pp. 392-396
    • Ganz, W.1    Donoso, R.2    Marcus, H.S.3
  • 36
    • 0020644098 scopus 로고
    • 2 consumption in the adult respiratory distress syndrome
    • 2 consumption in the adult respiratory distress syndrome. Chest. 1983;84:267-271.
    • (1983) Chest , vol.84 , pp. 267-271
    • Mohsenifar, Z.1    Goldbach, P.2    Tashkin, D.P.3
  • 37
    • 0029846418 scopus 로고    scopus 로고
    • The new pulmonary arterial catheters. Right ventricle ejections fraction and continuous cardiac output
    • Nelson LD. The new pulmonary arterial catheters. Right ventricle ejections fraction and continuous cardiac output. Crit Care Clin. 1996;52:795-818.
    • (1996) Crit Care Clin , vol.52 , pp. 795-818
    • Nelson, L.D.1
  • 38
    • 0031194642 scopus 로고    scopus 로고
    • Near continuous cardiac output thermodilution
    • Jansen JR, Johnson RW, Yan JY, et al. Near continuous cardiac output thermodilution. J Clin Monit. 1997;13:233-299.
    • (1997) J Clin Monit , vol.13 , pp. 233-299
    • Jansen, J.R.1    Johnson, R.W.2    Yan, J.Y.3
  • 39
    • 0029154767 scopus 로고
    • Continuous cardiac output: Agreement with Fick and bolus thermodilution methods
    • Thrush D, Downs JB, Smith RA. Continuous cardiac output: agreement with Fick and bolus thermodilution methods. J Cardiothorac Vasc Anesth. 1995;9:399-404.
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 399-404
    • Thrush, D.1    Downs, J.B.2    Smith, R.A.3
  • 40
    • 0030901770 scopus 로고    scopus 로고
    • Evaluation of the accuracy and response time of STAT-mode continuous cardiac output
    • Lazor MA, Pierce ET, Stanley GD, et al. Evaluation of the accuracy and response time of STAT-mode continuous cardiac output. J Cardiothorac Vasc Anesth. 1997;11:432-466.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 432-466
    • Lazor, M.A.1    Pierce, E.T.2    Stanley, G.D.3
  • 41
    • 0026631780 scopus 로고
    • End-diastolic volume. A better indicator of preload in the critically ill
    • Diebel LN, Wilson RF, Tagett MG, et al. End-diastolic volume. A better indicator of preload in the critically ill. Arch Surg. 1992;127:817-821.
    • (1992) Arch Surg , vol.127 , pp. 817-821
    • Diebel, L.N.1    Wilson, R.F.2    Tagett, M.G.3
  • 42
    • 0029023784 scopus 로고
    • Right ventricular end-diastolic volume as a measure of preload
    • Durham R, Neunaber K, Vogler G, et al. Right ventricular end-diastolic volume as a measure of preload. J Trauma. 1995;39:218-223.
    • (1995) J Trauma , vol.39 , pp. 218-223
    • Durham, R.1    Neunaber, K.2    Vogler, G.3
  • 43
    • 0029979828 scopus 로고    scopus 로고
    • Preload assessment in trauma patients during large-volume shock resuscitation
    • Chang MC, Blinman TA, Rutherford EJ, et al. Preload assessment in trauma patients during large-volume shock resuscitation. Arch Surg. 1996;131:728-731.
    • (1996) Arch Surg , vol.131 , pp. 728-731
    • Chang, M.C.1    Blinman, T.A.2    Rutherford, E.J.3
  • 44
    • 0031765602 scopus 로고    scopus 로고
    • Right ventricular end-diastolic volume index as a predictor of preload in patients on positive end-expiratory pressure
    • Cheatham ML, Nelson LD, Chang MC, et al. Right ventricular end-diastolic volume index as a predictor of preload in patients on positive end-expiratory pressure. Crit Care Med. 1998;26:1801-1806.
    • (1998) Crit Care Med , vol.26 , pp. 1801-1806
    • Cheatham, M.L.1    Nelson, L.D.2    Chang, M.C.3
  • 45
    • 0022486182 scopus 로고
    • Intraoperative right ventricular dysfunction detected with a right ventricular ejection fraction catheter
    • Hines R, Barash PG. Intraoperative right ventricular dysfunction detected with a right ventricular ejection fraction catheter. J Clin Monit Comput. 1986;2:206-208.
    • (1986) J Clin Monit Comput , vol.2 , pp. 206-208
    • Hines, R.1    Barash, P.G.2
  • 46
    • 0036800276 scopus 로고    scopus 로고
    • Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technology
    • Chaney JC, Derdak S. Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology. Crit Care Med. 2002;30:2238-2245.
    • (2002) Crit Care Med , vol.30 , pp. 2238-2245
    • Chaney, J.C.1    Derdak, S.2
  • 47
    • 0034834621 scopus 로고    scopus 로고
    • Outcome prediction of emergency patients by noninvasive hemodynamic monitoring
    • Shoemaker WC, Wo CC, Chan L, et al. Outcome prediction of emergency patients by noninvasive hemodynamic monitoring. Chest. 2001;120:528-537.
    • (2001) Chest , vol.120 , pp. 528-537
    • Shoemaker, W.C.1    Wo, C.C.2    Chan, L.3
  • 48
    • 0025995952 scopus 로고
    • Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects
    • Singer M, Allen MJ, Webb AR, et al. Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med. 1991;19:1132-1137.
    • (1991) Crit Care Med , vol.19 , pp. 1132-1137
    • Singer, M.1    Allen, M.J.2    Webb, A.R.3
  • 49
    • 0031946626 scopus 로고    scopus 로고
    • Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients
    • Lefrant JY, Bruelle P, Aya AGM, et al. Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med. 1998;24:347-352.
    • (1998) Intensive Care Med , vol.24 , pp. 347-352
    • Lefrant, J.Y.1    Bruelle, P.2    Aya, A.G.M.3
  • 50
    • 0028949112 scopus 로고
    • Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion in cardiac surgery
    • Mythen MG, Webb AR. Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion in cardiac surgery. Arch Surg. 1995;130:423-429.
    • (1995) Arch Surg , vol.130 , pp. 423-429
    • Mythen, M.G.1    Webb, A.R.2
  • 51
    • 0030843904 scopus 로고    scopus 로고
    • Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomized controlled trial
    • Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomized controlled trial. BMJ. 1997;315:909-912.
    • (1997) BMJ , vol.315 , pp. 909-912
    • Sinclair, S.1    James, S.2    Singer, M.3
  • 52
    • 0036792321 scopus 로고    scopus 로고
    • Goal directed intra-operation fluid administration reduces length of stay after major surgery
    • Gan TJ, Soppitt AB, Maroof M, et al. Goal directed intra-operation fluid administration reduces length of stay after major surgery. Anesthesiology. 2002;97:820-826.
    • (2002) Anesthesiology , vol.97 , pp. 820-826
    • Gan, T.J.1    Soppitt, A.B.2    Maroof, M.3
  • 53
    • 0029016594 scopus 로고
    • Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: A prospective criterion standard study
    • Haller M, Zollner C, Briegel J, et al. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study. Crit Care Med. 1995;23:860-866.
    • (1995) Crit Care Med , vol.23 , pp. 860-866
    • Haller, M.1    Zollner, C.2    Briegel, J.3
  • 54
    • 0033998711 scopus 로고    scopus 로고
    • Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: A prospective criterion standard study in patients after cardiac surgery
    • Zollner C, Haller M, Weiss M, et al. Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery. J Cardiothorac Vasc Anesth. 2000;14:125-129.
    • (2000) J Cardiothorac Vasc Anesth , vol.14 , pp. 125-129
    • Zollner, C.1    Haller, M.2    Weiss, M.3
  • 55
    • 0036152801 scopus 로고    scopus 로고
    • Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
    • Godje O, Hoke K, Goetz AE, et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med. 2002;30:52-58.
    • (2002) Crit Care Med , vol.30 , pp. 52-58
    • Godje, O.1    Hoke, K.2    Goetz, A.E.3
  • 56
    • 0030832772 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement: A comparison with thermodilution
    • Linton R, Band D, O'Brien T, et al. Lithium dilution cardiac output measurement: a comparison with thermodilution. Crit Care Med. 1997;25:1796-1800.
    • (1997) Crit Care Med , vol.25 , pp. 1796-1800
    • Linton, R.1    Band, D.2    O'Brien, T.3
  • 57
    • 0036800148 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement: A clinical assessment of central venous and peripheral venous indicator injection
    • Garcia-Rodriguez C, Pittman J, Cassell CH, et al. Lithium dilution cardiac output measurement: a clinical assessment of central venous and peripheral venous indicator injection. Crit Care Med. 2002;30:2199-2204.
    • (2002) Crit Care Med , vol.30 , pp. 2199-2204
    • Garcia-Rodriguez, C.1    Pittman, J.2    Cassell, C.H.3
  • 58
    • 0033009507 scopus 로고    scopus 로고
    • A meta-analysis of three decades of validating thoracic impedance cardiography
    • Raaijmakers E, Faes TJ, Scholten RJ, et al. A meta-analysis of three decades of validating thoracic impedance cardiography. Crit Care Med. 1999;27:1203-1213.
    • (1999) Crit Care Med , vol.27 , pp. 1203-1213
    • Raaijmakers, E.1    Faes, T.J.2    Scholten, R.J.3
  • 59
    • 0031060466 scopus 로고    scopus 로고
    • Measuring cardiac output in critically ill patients: Disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods
    • Sherman MS, Kosinski R, Paz HL, et al. Measuring cardiac output in critically ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods. Cardiology. 1997;88:19-25.
    • (1997) Cardiology , vol.88 , pp. 19-25
    • Sherman, M.S.1    Kosinski, R.2    Paz, H.L.3
  • 60
    • 0027969067 scopus 로고
    • Gastric tonometry supplements information provided by systemic indicator of oxygen transportation
    • Chang MC, Cheatham ML, Nelson LD, et al. Gastric tonometry supplements information provided by systemic indicator of oxygen transportation. J Trauma. 1994;37:488-494.
    • (1994) J Trauma , vol.37 , pp. 488-494
    • Chang, M.C.1    Cheatham, M.L.2    Nelson, L.D.3
  • 61
    • 0028040543 scopus 로고
    • Tonometry to assess the adequacy of splanchnic oxygenation in the critically ill patient
    • Arnold J, Hendriks J, Bruining H. Tonometry to assess the adequacy of splanchnic oxygenation in the critically ill patient. Intensive Care Med. 1994;20:452-456.
    • (1994) Intensive Care Med , vol.20 , pp. 452-456
    • Arnold, J.1    Hendriks, J.2    Bruining, H.3
  • 62
    • 0032877674 scopus 로고    scopus 로고
    • How to use articles about diagnostic technology: Gastric tonometry
    • Keenan SP, Guyatt GH, Sibbald WJ, et al. How to use articles about diagnostic technology: gastric tonometry. Crit Care Med. 1999;27:1726-1731.
    • (1999) Crit Care Med , vol.27 , pp. 1726-1731
    • Keenan, S.P.1    Guyatt, G.H.2    Sibbald, W.J.3
  • 63
    • 0031759172 scopus 로고    scopus 로고
    • Threshold values of intramucosal pH and mucosal-arterial CO2 gap during shock resuscitation
    • Miller PR, Kincaid EH, Wayne MJ, et al. Threshold values of intramucosal pH and mucosal-arterial CO2 gap during shock resuscitation. Trauma. 1998;45:868-872.
    • (1998) Trauma , vol.45 , pp. 868-872
    • Miller, P.R.1    Kincaid, E.H.2    Wayne, M.J.3
  • 65
    • 0034831025 scopus 로고    scopus 로고
    • Sublingual capnography: A clinical validation study
    • Marik PE. Sublingual capnography: a clinical validation study. Chest. 2001;120:923-927.
    • (2001) Chest , vol.120 , pp. 923-927
    • Marik, P.E.1
  • 66
    • 0018425044 scopus 로고
    • New concepts in diagnosis and fluid treatment in circulatory shock
    • Weil MH, Henning RJ. New concepts in diagnosis and fluid treatment in circulatory shock. Anesth Analg. 1979;58:124-132.
    • (1979) Anesth Analg , vol.58 , pp. 124-132
    • Weil, M.H.1    Henning, R.J.2
  • 67
    • 0025884214 scopus 로고
    • A randomized controlled trial of right heart catheterization in critically ill patients
    • Ontario Intensive Care Group. A randomized controlled trial of right heart catheterization in critically ill patients. Intensive Care Med. 1991;6:91-95.
    • (1991) Intensive Care Med , vol.6 , pp. 91-95
  • 68
    • 0024273739 scopus 로고
    • Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients
    • Shoemaker WC, Appel PL, Kram HB, et al. Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. Chest. 1988;94:1176-1186.
    • (1988) Chest , vol.94 , pp. 1176-1186
    • Shoemaker, W.C.1    Appel, P.L.2    Kram, H.B.3
  • 69
    • 0027427633 scopus 로고
    • A randomized clinical trial of the effects of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients
    • Boyd O, Ground RM, Bennett ED. A randomized clinical trial of the effects of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. JAMA. 1993;270:2699-2707.
    • (1993) JAMA , vol.270 , pp. 2699-2707
    • Boyd, O.1    Ground, R.M.2    Bennett, E.D.3
  • 70
    • 0028274011 scopus 로고
    • Pulmonary artery catheterization in critically ill patients; a prospective analysis of outcome changes associated with catheter-prompted changes in therapy
    • Minoz O, Rauss A, Rekik N, et al. Pulmonary artery catheterization in critically ill patients; a prospective analysis of outcome changes associated with catheter-prompted changes in therapy. Crit Care Med. 1994;27:573-579.
    • (1994) Crit Care Med , vol.27 , pp. 573-579
    • Minoz, O.1    Rauss, A.2    Rekik, N.3
  • 71
    • 0030754634 scopus 로고    scopus 로고
    • Pulmonary artery catheterization: A narrative systematic critique of randomized controlled trials and recommendations for the future
    • Ivanov R, Allen J, Sandham D, et al. Pulmonary artery catheterization: a narrative systematic critique of randomized controlled trials and recommendations for the future. New Horizon. 1997;5:268-276.
    • (1997) New Horizon , vol.5 , pp. 268-276
    • Ivanov, R.1    Allen, J.2    Sandham, D.3
  • 72
    • 0034078655 scopus 로고    scopus 로고
    • The incidence of major morbidity in critically ill patients managed with pulmonary artery catheter. A meta-analysis
    • Ivanov R, Allen J, Calvin JE. The incidence of major morbidity in critically ill patients managed with pulmonary artery catheter. A meta-analysis. Crit Care Med. 2000;28:615-619.
    • (2000) Crit Care Med , vol.28 , pp. 615-619
    • Ivanov, R.1    Allen, J.2    Calvin, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.