메뉴 건너뛰기




Volumn 13, Issue SUPPL. 5, 2003, Pages

Multislice CT: Update on radiation and screening

Author keywords

CT dose estimation; Multislice CT; Radiation

Indexed keywords

ARTERY CALCIFICATION; ARTICLE; CANCER CENTER; COLORECTAL CANCER; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY; FREQUENCY MODULATION; HEMATURIA; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGING SYSTEM; KIDNEY TUMOR; LUNG CANCER; PRIORITY JOURNAL; RADIATION BEAM; RADIATION DETECTOR; RADIATION DOSE; RADIATION EXPOSURE; SCREENING TEST; STANDARDIZATION; UNITED STATES;

EID: 0842345505     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-003-2107-1     Document Type: Article
Times cited : (13)

References (31)
  • 2
    • 0842336124 scopus 로고    scopus 로고
    • Nationwide evaluation of X-ray trends (NEXT) survey of patient radiation exposure from computed tomographic (CT) examinations in the United States
    • Scientific Presentation at the Annual Meeting of the Radiological Society of North America, Chicago, November 2001
    • Spelic DC, Suleiman OH, Kaczmarek RV, Stern SH, Moyal A (2001) Nationwide evaluation of X-ray trends (NEXT) survey of patient radiation exposure from computed tomographic (CT) examinations in the United States. Scientific Presentation at the Annual Meeting of the Radiological Society of North America, Chicago, November 2001
    • (2001)
    • Spelic, D.C.1    Suleiman, O.H.2    Kaczmarek, R.V.3    Stern, S.H.4    Moyal, A.5
  • 3
    • 0034877918 scopus 로고    scopus 로고
    • A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: Estimates of the collective dose savings achieved
    • Crawley MT, Booth A, Wainwright A (2001) A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: estimates of the collective dose savings achieved. Br J Radiol 74:607-614
    • (2001) Br. J. Radiol. , vol.74 , pp. 607-614
    • Crawley, M.T.1    Booth, A.2    Wainwright, A.3
  • 4
    • 0003805399 scopus 로고
    • Board on Radiation Effects Research, National Research Council BIER V, National Academy Press, Washington, D.C
    • Board on Radiation Effects Research, National Research Council (1990) Health effects of exposure to low levels of ionizing radiation. BIER V, National Academy Press, Washington, D.C.
    • (1990) Health Effects of Exposure to Low Levels of Ionizing Radiation
  • 6
    • 0025348196 scopus 로고
    • The 1986 and 1988 UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) reports: Findings and implications
    • Mettler FA, Sinclair WK, Anspaugh L, Edington C, Harley JH, Ricks RC et al. (1990) The 1986 and 1988 UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) reports: findings and implications. Health Phys 58:241-250
    • (1990) Health Phys. , vol.58 , pp. 241-250
    • Mettler, F.A.1    Sinclair, W.K.2    Anspaugh, L.3    Edington, C.4    Harley, J.H.5    Ricks, R.C.6
  • 7
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR 176:289-296
    • (2001) AJR , vol.176 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 8
    • 0029644266 scopus 로고
    • Effects of radiation on man
    • Meyniel G (1995) Effects of radiation on man. Rev Prat 45:15-18
    • (1995) Rev. Prat. , vol.45 , pp. 15-18
    • Meyniel, G.1
  • 9
    • 0842336123 scopus 로고    scopus 로고
    • The application of ALARA for occupational exposures NCRP (National Council on Radiation Protection and Measurements) Statement no. 8, issued 8 June 1999. National Council on Radiation Protection
    • The application of ALARA for occupational exposures NCRP (National Council on Radiation Protection and Measurements) (2000). Statement no. 8, issued 8 June 1999. National Council on Radiation Protection. Health Phys 78 (Suppl 2):S28-S29
    • (2000) Health Phys. , vol.78 , Issue.SUPPL. 2
  • 10
    • 0003892092 scopus 로고    scopus 로고
    • European guidelines on quality criteria for computed tomography
    • EUR 16262 Commission of the European Community Report EUR 16262 EN
    • EUR 16262 Commission of the European Community (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262 EN
    • (1999)
  • 11
    • 0036938794 scopus 로고    scopus 로고
    • Pediatric CT: Practical approach to diminish the radiation dose
    • Frush DP (2002) Pediatric CT: practical approach to diminish the radiation dose. Pediatr Radiol 32:714-717
    • (2002) Pediatr. Radiol. , vol.32 , pp. 714-717
    • Frush, D.P.1
  • 13
    • 0037305308 scopus 로고    scopus 로고
    • Low-dose unenhanced multidetector CT of patients with suspected renal colic
    • Tack D, Sourtzis S, Delpierre I, de Maertelaer V, Gevenois PA (2003) Low-dose unenhanced multidetector CT of patients with suspected renal colic. AJR 180:305-311
    • (2003) AJR , vol.180 , pp. 305-311
    • Tack, D.1    Sourtzis, S.2    Delpierre, I.3    de Maertelaer, V.4    Gevenois, P.A.5
  • 14
    • 0035143460 scopus 로고    scopus 로고
    • Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital
    • Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton CG et al. (2001) Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large children's hospital. AJR 176:303-306
    • (2001) AJR , vol.176 , pp. 303-306
    • Donnelly, L.F.1    Emery, K.H.2    Brody, A.S.3    Laor, T.4    Gylys-Morin, V.M.5    Anton, C.G.6
  • 15
    • 0036839121 scopus 로고    scopus 로고
    • Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality
    • Kalra MK, Prasad S, Saini S, Blake MA, Varghese J, Halpern EF et al. (2002) Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality. AJR 179:1101-1106
    • (2002) AJR , vol.179 , pp. 1101-1106
    • Kalra, M.K.1    Prasad, S.2    Saini, S.3    Blake, M.A.4    Varghese, J.5    Halpern, E.F.6
  • 16
    • 0036176707 scopus 로고    scopus 로고
    • Improved pediatric multidetector body CT using a size-based color-coded format
    • Frush DP, Soden B, Frush KS, Lowry C (2002) Improved pediatric multidetector body CT using a size-based color-coded format. AJR 178:721-726
    • (2002) AJR , vol.178 , pp. 721-726
    • Frush, D.P.1    Soden, B.2    Frush, K.S.3    Lowry, C.4
  • 17
    • 0031978536 scopus 로고    scopus 로고
    • Low-dose spiral computed tomography of the thorax: Comparison with the standard-dose technique
    • Takahashi M, Maguire WM, Ashtari M, Khan A, Papp Z, Alberico R et al. (1998) Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique. Invest Radiol 33:68-73
    • (1998) Invest. Radiol. , vol.33 , pp. 68-73
    • Takahashi, M.1    Maguire, W.M.2    Ashtari, M.3    Khan, A.4    Papp, Z.5    Alberico, R.6
  • 18
    • 0034823356 scopus 로고    scopus 로고
    • An assessment of low-dose high resolution CT in the detection of benign asbestos-related pleural abnormalities
    • Michel JL, Reynier C, Avy G, Bard JJ, Gabrillargues D, Catilina P (2001) An assessment of low-dose high resolution CT in the detection of benign asbestos-related pleural abnormalities. J Radiol 82:922-923
    • (2001) J. Radiol. , vol.82 , pp. 922-923
    • Michel, J.L.1    Reynier, C.2    Avy, G.3    Bard, J.J.4    Gabrillargues, D.5    Catilina, P.6
  • 19
    • 0037369945 scopus 로고    scopus 로고
    • CT colonography: Digital subtraction bowel cleansing with mucosal reconstruction initial observations
    • Zalis ME, Perumpillichira J, Del Frate C, Hahn PF (2003) CT colonography: digital subtraction bowel cleansing with mucosal reconstruction initial observations. Radiology 226:911-917
    • (2003) Radiology , vol.226 , pp. 911-917
    • Zalis, M.E.1    Perumpillichira, J.2    Del Frate, C.3    Hahn, P.F.4
  • 20
    • 0036882306 scopus 로고    scopus 로고
    • Virtual colonoscopy: Chances for a screening procedure?
    • Rust GF, Reiser M (2002) Virtual colonoscopy: chances for a screening procedure? Radiologe 42:617-621
    • (2002) Radiologe , vol.42 , pp. 617-621
    • Rust, G.F.1    Reiser, M.2
  • 21
    • 0035740279 scopus 로고    scopus 로고
    • Comprehensive evaluation of patients with haematuria on multi-slice computed tomography scanner: Protocol design and preliminary observations
    • Chai RY, Jhaveri K, Saini S, Hahn PF, Nichols S, Mueller PR (2001) Comprehensive evaluation of patients with haematuria on multi-slice computed tomography scanner: protocol design and preliminary observations. Australas Radiol 45:536-538
    • (2001) Australas. Radiol. , vol.45 , pp. 536-538
    • Chai, R.Y.1    Jhaveri, K.2    Saini, S.3    Hahn, P.F.4    Nichols, S.5    Mueller, P.R.6
  • 23
    • 0034055634 scopus 로고    scopus 로고
    • Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: Evaluation of six anatomical regions
    • Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender W et al. (2000) Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol 10:391-394
    • (2000) Eur. Radiol. , vol.10 , pp. 391-394
    • Greess, H.1    Wolf, H.2    Baum, U.3    Lell, M.4    Pirkl, M.5    Kalender, W.6
  • 24
    • 0043033136 scopus 로고    scopus 로고
    • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
    • Greess H, Nomayr A, Wolf H, Baum U, Lell M, Bowing B et al. (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571-1576
    • (2002) Eur. Radiol. , vol.12 , pp. 1571-1576
    • Greess, H.1    Nomayr, A.2    Wolf, H.3    Baum, U.4    Lell, M.5    Bowing, B.6
  • 25
    • 0037600583 scopus 로고    scopus 로고
    • Can noise reduction filters improve low radiation dose chest CT images? Pilot Study
    • Kalra MK, Wittram C, Maher MM, Sharma A, Avinash GB, Karau K et al. (2003) Can noise reduction filters improve low radiation dose chest CT images? Pilot Study. Radiology 228:251-256
    • (2003) Radiology , vol.228 , pp. 251-256
    • Kalra, M.K.1    Wittram, C.2    Maher, M.M.3    Sharma, A.4    Avinash, G.B.5    Karau, K.6
  • 26
    • 0037600566 scopus 로고    scopus 로고
    • Low-dose abdominal CT: Evaluation of image improvement from noise reduction filters. Pilot study
    • Kalra MK, Maher MM, Sahani DV, Blake MA, Hahn PF, Avinash GB et al. (2003) Low-dose abdominal CT: evaluation of image improvement from noise reduction filters. Pilot study. Radiology 228:257-264
    • (2003) Radiology , vol.228 , pp. 257-264
    • Kalra, M.K.1    Maher, M.M.2    Sahani, D.V.3    Blake, M.A.4    Hahn, P.F.5    Avinash, G.B.6
  • 27
    • 0842314625 scopus 로고    scopus 로고
    • Lesion detection on reduced radiation dose CT images processed with noise reduction filters
    • (abstract) 645
    • Kalra MK, Maher MM, Lucey BC, Blake M, Karau K, Saini S (2002) Lesion detection on reduced radiation dose CT images processed with noise reduction filters. RSNA (abstract) 645
    • (2002) RSNA
    • Kalra, M.K.1    Maher, M.M.2    Lucey, B.C.3    Blake, M.4    Karau, K.5    Saini, S.6
  • 29
    • 0042635388 scopus 로고    scopus 로고
    • Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating
    • Jakobs TF, Wintersperger BJ, Herzog P, Flohr T, Suess C, Knez A et al. (2003) Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating. Eur Radiol 13:1923-1930
    • (2003) Eur. Radiol. , vol.13 , pp. 1923-1930
    • Jakobs, T.F.1    Wintersperger, B.J.2    Herzog, P.3    Flohr, T.4    Suess, C.5    Knez, A.6
  • 30
    • 0037408003 scopus 로고    scopus 로고
    • Colorectal cancer screening with CT colonography, colonoscopy, and double-contrast barium enema examination: Prospective assessment of patient perceptions and preferences
    • Gluecker TM, Johnson CD, Harmsen WS, Offord KP, Harris AM, Wilson LA et al. (2003) Colorectal cancer screening with CT colonography, colonoscopy, and double-contrast barium enema examination: prospective assessment of patient perceptions and preferences. Radiology 227:378-384
    • (2003) Radiology , vol.227 , pp. 378-384
    • Gluecker, T.M.1    Johnson, C.D.2    Harmsen, W.S.3    Offord, K.P.4    Harris, A.M.5    Wilson, L.A.6
  • 31
    • 0038638015 scopus 로고    scopus 로고
    • Screening for cancer with computed tomography
    • Swensen SJ (2003) Screening for cancer with computed tomography. Br Med J 326:894-895
    • (2003) Br. Med. J. , vol.326 , pp. 894-895
    • Swensen, S.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.