메뉴 건너뛰기




Volumn 340, Issue 1-2, 2004, Pages 213-217

Performance characteristics of the IMMULITE 2000 erythropoietin assay

Author keywords

Anemia; Chemiluminescent immunoassay; Heterophile antibody; Interference; Polycythemia

Indexed keywords

ERYTHROPOIETIN;

EID: 0842330774     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cccn.2003.11.005     Document Type: Article
Times cited : (26)

References (14)
  • 1
    • 0026526168 scopus 로고
    • Erythropoietin: Structure, control of production, and function
    • Jelkmann W. Erythropoietin: structure, control of production, and function. Physiol. Rev. 72:1992;449-489.
    • (1992) Physiol. Rev. , vol.72 , pp. 449-489
    • Jelkmann, W.1
  • 2
    • 0022606620 scopus 로고
    • Determination of serum immunoreactive erythropoietin in the investigation of erythrocytosis
    • Cotes P.M., Dore C.J., Yin J.A., Lewis S.M., Messinezy M., Pearson T.C. et al. Determination of serum immunoreactive erythropoietin in the investigation of erythrocytosis. N. Engl. J. Med. 315:1986;283-287.
    • (1986) N. Engl. J. Med. , vol.315 , pp. 283-287
    • Cotes, P.M.1    Dore, C.J.2    Yin, J.A.3    Lewis, S.M.4    Messinezy, M.5    Pearson, T.C.6
  • 3
    • 0021967288 scopus 로고
    • Serum immunoreactive erythropoietin concentrations in patients with polycystic kidney disease as compared with other hemodialysis patients
    • Chandra M., Miller M.E., Garcia J.F., Mossey R.T., McVicar M. Serum immunoreactive erythropoietin concentrations in patients with polycystic kidney disease as compared with other hemodialysis patients. Nephron. 39:1985;26-29.
    • (1985) Nephron , vol.39 , pp. 26-29
    • Chandra, M.1    Miller, M.E.2    Garcia, J.F.3    Mossey, R.T.4    McVicar, M.5
  • 4
    • 0019805802 scopus 로고
    • Serum erythropoietin (ESF) titers in polycythemia
    • de Klerk G., Rosengarten P.C., Vet R.J., Goudsmit R. Serum erythropoietin (ESF) titers in polycythemia. Blood. 58:1981;1171-1174.
    • (1981) Blood , vol.58 , pp. 1171-1174
    • De Klerk, G.1    Rosengarten, P.C.2    Vet, R.J.3    Goudsmit, R.4
  • 5
    • 0024515126 scopus 로고
    • Circadian rhythm of erythropoietin in human serum
    • Wide L., Bengtsson C., Birgegard G. Circadian rhythm of erythropoietin in human serum. Br. J. Haematol. 72:1989;85-90.
    • (1989) Br. J. Haematol. , vol.72 , pp. 85-90
    • Wide, L.1    Bengtsson, C.2    Birgegard, G.3
  • 6
    • 0026629866 scopus 로고
    • Serum erythropoietin in the diagnosis of polycythaemia and after phlebotomy treatment
    • Birgegard G., Wide L. Serum erythropoietin in the diagnosis of polycythaemia and after phlebotomy treatment. Br. J. Haematol. 81:1992;603-606.
    • (1992) Br. J. Haematol. , vol.81 , pp. 603-606
    • Birgegard, G.1    Wide, L.2
  • 7
    • 0842345174 scopus 로고
    • Geneva: World Health Organization
    • WHO Expert Committee on Biological Standardization Forty-first report. 1991;10 World Health Organization, Geneva.
    • (1991) Forty-first Report , pp. 10
  • 9
    • 0020043548 scopus 로고
    • Immunoreactive erythropoietin in serum: I. Evidence for the validity of the assay method and the physiological relevance of estimates
    • Cotes P.M. Immunoreactive erythropoietin in serum: I. Evidence for the validity of the assay method and the physiological relevance of estimates. Br. J. Haematol. 50:1982;427-438.
    • (1982) Br. J. Haematol. , vol.50 , pp. 427-438
    • Cotes, P.M.1
  • 11
    • 0037635335 scopus 로고    scopus 로고
    • Long-term exposure to intermittent hypoxia results in increased hemoglobin mass, reduced plasma volume, and elevated erythropoietin plasma concentrations in man
    • Heinicke K., Prommer N., Cajigal J., Viola T., Behn C., Schmidt W. Long-term exposure to intermittent hypoxia results in increased hemoglobin mass, reduced plasma volume, and elevated erythropoietin plasma concentrations in man. Eur. J. Appl. Physiol. 88:2003;535-543.
    • (2003) Eur. J. Appl. Physiol. , vol.88 , pp. 535-543
    • Heinicke, K.1    Prommer, N.2    Cajigal, J.3    Viola, T.4    Behn, C.5    Schmidt, W.6
  • 12
    • 0023853204 scopus 로고
    • Heterophilic antibodies: A problem for all immunoassays
    • Boscato L.M., Stuart M.C. Heterophilic antibodies: a problem for all immunoassays. Clin. Chem. 34:1988;27-33.
    • (1988) Clin. Chem. , vol.34 , pp. 27-33
    • Boscato, L.M.1    Stuart, M.C.2
  • 13
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • Kricka L.J. Human anti-animal antibody interferences in immunological assays. Clin. Chem. 45:1999;942-956.
    • (1999) Clin. Chem. , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 14
    • 0009651997 scopus 로고
    • Interference due to heterophilic antibodies in immunometric assays: You can't win
    • [Abstract]
    • Alvarez F.V., Scott M.G. Interference due to heterophilic antibodies in immunometric assays: you can't win. [Abstract] Clin. Chem. 39:1993;1268.
    • (1993) Clin. Chem. , vol.39 , pp. 1268
    • Alvarez, F.V.1    Scott, M.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.