메뉴 건너뛰기




Volumn 19, Issue 2, 2004, Pages 245-254

Automatic Model-Based Evaluation of Magnetic Resonance-Guided Radio Frequency Ablation Lesions with Histological Correlation

Author keywords

Automatic segmentation; Histology; Image analysis; Interventional magnetic resonance imaging; Medical image processing; Radio frequency thermal ablation

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; AUTOMATION; CATHETER ABLATION; CELL DAMAGE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; DIFFUSION WEIGHTED IMAGING; IMAGE ANALYSIS; INTERMETHOD COMPARISON; MAGNETIC RESONANCE IMAGING GUIDANCE; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RABBIT; THIGH; THREE DIMENSIONAL IMAGING; TISSUE SECTION; TISSUE SLICE;

EID: 0842326030     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.10450     Document Type: Article
Times cited : (20)

References (22)
  • 1
    • 0035041810 scopus 로고    scopus 로고
    • Radiofrequency tissue ablation: Physical principles and techniques for increasing coagulation necrosis
    • Goldberg NS, Gazelle GS. Radiofrequency tissue ablation: physical principles and techniques for increasing coagulation necrosis. Hepatogastroenterology 2001;48:359-367.
    • (2001) Hepatogastroenterology , vol.48 , pp. 359-367
    • Goldberg, N.S.1    Gazelle, G.S.2
  • 2
    • 0031932248 scopus 로고    scopus 로고
    • Calculated RF electric field and temperature distributions in RF thermal ablation: Comparison with gel experiments and liver imaging
    • Cheng YC, Brown RW, Chung YC, et al. Calculated RF electric field and temperature distributions in RF thermal ablation: comparison with gel experiments and liver imaging. J Magn Reson Imaging 1998;8:70-76.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 70-76
    • Cheng, Y.C.1    Brown, R.W.2    Chung, Y.C.3
  • 3
    • 0033814469 scopus 로고    scopus 로고
    • Thermal lesion conspicuity following interstitial radiofrequency thermal tumor ablation in humans: A comparison of STIR, turbo spin-echo T2-weighted, and contrast-enhanced T1-weighted MR images at 0.2 T
    • Aschoff AJ, Rafie N, Jesberger JA, Duerk JL, Lewin JS. Thermal lesion conspicuity following interstitial radiofrequency thermal tumor ablation in humans: a comparison of STIR, turbo spin-echo T2-weighted, and contrast-enhanced T1-weighted MR images at 0.2 T. J Magn Reson Imaging 2000;12:584-589.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 584-589
    • Aschoff, A.J.1    Rafie, N.2    Jesberger, J.A.3    Duerk, J.L.4    Lewin, J.S.5
  • 4
    • 0042829296 scopus 로고    scopus 로고
    • Subacute changes in lesion conspicuity and geometry following MR-guided radiofrequency ablation
    • Lazebnik RS, Weinberg BD, Breen MS, Lewin JS, Wilson DL. Subacute changes in lesion conspicuity and geometry following MR-guided radiofrequency ablation. J Magn Reson Imaging 2003;18: 487-495.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 487-495
    • Lazebnik, R.S.1    Weinberg, B.D.2    Breen, M.S.3    Lewin, J.S.4    Wilson, D.L.5
  • 5
    • 0031446576 scopus 로고    scopus 로고
    • Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment preliminary ex vivo and in vivo results
    • Steiner P, Botnar R, Goldberg SN, Gazelle GS, Debatin JF. Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment preliminary ex vivo and in vivo results. Invest Radiol 1997;32:671-678.
    • (1997) Invest Radiol , vol.32 , pp. 671-678
    • Steiner, P.1    Botnar, R.2    Goldberg, S.N.3    Gazelle, G.S.4    Debatin, J.F.5
  • 8
    • 0031404897 scopus 로고    scopus 로고
    • Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging
    • Chung YC, Duerk JL, Lewin JS. Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging. Invest Radiol 1997;32:466-474.
    • (1997) Invest Radiol , vol.32 , pp. 466-474
    • Chung, Y.C.1    Duerk, J.L.2    Lewin, J.S.3
  • 9
    • 0036789238 scopus 로고    scopus 로고
    • Three-dimensional model of lesion geometry for evaluation of MR-guided thermal ablation therapy
    • Lazebnik RS, Weinberg BD, Breen MS, Lewin JS, Wilson DL. Three-dimensional model of lesion geometry for evaluation of MR-guided thermal ablation therapy. Acad Radiol 2002;9:1128-1138.
    • (2002) Acad Radiol , vol.9 , pp. 1128-1138
    • Lazebnik, R.S.1    Weinberg, B.D.2    Breen, M.S.3    Lewin, J.S.4    Wilson, D.L.5
  • 10
    • 0031934807 scopus 로고    scopus 로고
    • Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility
    • Lewin JS, Connell CF, Duerk JL, et al. Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: clinical trial for evaluation of safety and feasibility. J Magn Reson Imaging 1998;8:40-47.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 40-47
    • Lewin, J.S.1    Connell, C.F.2    Duerk, J.L.3
  • 11
    • 0038787489 scopus 로고    scopus 로고
    • Three dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response
    • Breen MS, Lancaster TL, Lazebnik RS, Nour SG, Lewin JS, Wilson DL. Three dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response. J Magn Reson Imaging 2003;18:90-102.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 90-102
    • Breen, M.S.1    Lancaster, T.L.2    Lazebnik, R.S.3    Nour, S.G.4    Lewin, J.S.5    Wilson, D.L.6
  • 12
    • 0024831978 scopus 로고
    • Changes in birefringence as markers of thermal damage in tissues
    • Thomsen S, Pearce JA, Cheong WF. Changes in birefringence as markers of thermal damage in tissues. IEEE Trans Biomed Eng 1989;36:1174-1179.
    • (1989) IEEE Trans Biomed Eng , vol.36 , pp. 1174-1179
    • Thomsen, S.1    Pearce, J.A.2    Cheong, W.F.3
  • 13
    • 0842302179 scopus 로고    scopus 로고
    • Three-dimensional registration of medical image data to histological sections with model-based evaluation
    • in press
    • Breen MS, Lazebnik RS, Lewin JS, Wilson DL. Three-dimensional registration of medical image data to histological sections with model-based evaluation. Ann Biomed Eng. 2003 (in press).
    • (2003) Ann Biomed Eng
    • Breen, M.S.1    Lazebnik, R.S.2    Lewin, J.S.3    Wilson, D.L.4
  • 14
    • 0013329664 scopus 로고    scopus 로고
    • Volume registration using needle paths and point landmarks for evaluation of interventional MRI treatments
    • Lazebnik RS, Lancaster TL, Breen MS, Lewin JS, Wilson DL. Volume registration using needle paths and point landmarks for evaluation of interventional MRI treatments. IEEE Trans Med Imaging 2003;22:653-660.
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 653-660
    • Lazebnik, R.S.1    Lancaster, T.L.2    Breen, M.S.3    Lewin, J.S.4    Wilson, D.L.5
  • 16
    • 0029294873 scopus 로고
    • Tissue ablation with radiofrequency: Effect of probe size, gauge, duration, and temperature on lesion volume
    • Goldberg SN, Gazelle GS, Dawson SL, Rittman WJ, Mueller PR, Rosenthal DI. Tissue ablation with radiofrequency: effect of probe size, gauge, duration, and temperature on lesion volume. Acad Radiol 1995;2:399-404.
    • (1995) Acad Radiol , vol.2 , pp. 399-404
    • Goldberg, S.N.1    Gazelle, G.S.2    Dawson, S.L.3    Rittman, W.J.4    Mueller, P.R.5    Rosenthal, D.I.6
  • 17
    • 0032173365 scopus 로고    scopus 로고
    • Methods for providing probe position and temperature information on MR images during interventional procedures
    • Patel KC, Duerk JL, Zhang Q, et al. Methods for providing probe position and temperature information on MR images during interventional procedures. IEEE Trans Med Imaging 1998;17:794-802.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 794-802
    • Patel, K.C.1    Duerk, J.L.2    Zhang, Q.3
  • 18
    • 0034469036 scopus 로고    scopus 로고
    • Visualization, tracking, and navigation of instruments for magnetic resonance imaging-guided endovascular procedures
    • Wendt M, Wacker FK. Visualization, tracking, and navigation of instruments for magnetic resonance imaging-guided endovascular procedures. Top Magn Reson Imaging 2000;11:163-172.
    • (2000) Top Magn Reson Imaging , vol.11 , pp. 163-172
    • Wendt, M.1    Wacker, F.K.2
  • 22
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • Nelder JA, Mead R. A simplex method for function minimization. Comput J 1965;7:308-313.
    • (1965) Comput J , vol.7 , pp. 308-313
    • Nelder, J.A.1    Mead, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.