메뉴 건너뛰기




Volumn 21, Issue 1, 2004, Pages 1-6

Clinical Applicability for the Assessment of the Valvular Mitral Stenosis Severity with Doppler Echocardiography and the Proximal Isovelocity Surface Area (PISA) Method

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CALCULATION; CLINICAL ARTICLE; CLINICAL EXAMINATION; COLOR ULTRASOUND FLOWMETRY; CONTROLLED STUDY; CORRELATION COEFFICIENT; DOPPLER ECHOCARDIOGRAPHY; FEASIBILITY STUDY; FEMALE; HEART BEAT; HEART RATE; HEMODYNAMICS; HUMAN; MALE; MITRAL VALVE STENOSIS; PRIORITY JOURNAL; PROXIMAL ISOVELOCITY SURFACE AREA METHOD; QUANTITATIVE ANALYSIS; RHEUMATIC HEART DISEASE; SINUS RHYTHM; STANDARD; VALIDATION PROCESS;

EID: 0842313169     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.0742-2822.2004.03057.x     Document Type: Article
Times cited : (18)

References (18)
  • 1
    • 0018355102 scopus 로고
    • Reliability and reproducibility of measurement of the stenotic mitral valve orifice
    • Martin RP, Rakowski H, Kleiman JH: Reliability and reproducibility of measurement of the stenotic mitral valve orifice. Am J Cardiol 1979;43:560-568.
    • (1979) Am J Cardiol , vol.43 , pp. 560-568
    • Martin, R.P.1    Rakowski, H.2    Kleiman, J.H.3
  • 2
    • 0022613315 scopus 로고
    • Comparative accuracy of two dimensional echocardiography and Doppler pressure halftime methods in assessing the severity of mitral stenosis in patients with and without prior commisurotomy
    • Smith MD, Handshoe R, Handshoe S: Comparative accuracy of two dimensional echocardiography and Doppler pressure halftime methods in assessing the severity of mitral stenosis in patients with and without prior commisurotomy. Circulation 1986;73:100-107.
    • (1986) Circulation , vol.73 , pp. 100-107
    • Smith, M.D.1    Handshoe, R.2    Handshoe, S.3
  • 3
    • 0028260805 scopus 로고
    • Accurate measurment of the transmitral gradient in patients with mitral stenosis; a simultaneous catheterization and Doppler echocardiographic study
    • Nishimura R, Rihal C, Tajik J. Accurate measurment of the transmitral gradient in patients with mitral stenosis; a simultaneous catheterization and Doppler echocardiographic study. J Am Coll Cardiol 1994;24:152-158.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 152-158
    • Nishimura, R.1    Rihal, C.2    Tajik, J.3
  • 4
    • 0024074150 scopus 로고
    • Pressure half-time does not always predict mitral valve area correctly
    • Loyd D, Wranne B: Pressure half-time does not always predict mitral valve area correctly. J Am Soc Echocardiogr 1988;1:313-321.
    • (1988) J Am Soc Echocardiogr , vol.1 , pp. 313-321
    • Loyd, D.1    Wranne, B.2
  • 5
    • 0025029948 scopus 로고
    • Aortic regurgitation shortens Doppler pressure half-time in mitral stenosis: Clinical evidence, in vitro simulation and theoretic analysis
    • Flachśkampf FA, Weyman AE, Gillam LD: Aortic regurgitation shortens Doppler pressure half-time in mitral stenosis: Clinical evidence, in vitro simulation and theoretic analysis. J Am Coll Cardiol 1990;16:396-404.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 396-404
    • Flachśkampf, F.A.1    Weyman, A.E.2    Gillam, L.D.3
  • 6
    • 0024577227 scopus 로고
    • Reassessment of valve area determination in mitral stenosis by the pressure half-time method: Impact of left ventricular stiffness and peak diastolic pressure difference
    • Karp K, Teien D, Bjerle P: Reassessment of valve area determination in mitral stenosis by the pressure half-time method: impact of left ventricular stiffness and peak diastolic pressure difference. J Am Coll Cardiol 1989;13:594-599.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 594-599
    • Karp, K.1    Teien, D.2    Bjerle, P.3
  • 7
    • 0023753489 scopus 로고
    • Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy
    • Thomas JD, Wilkins GT, Choong CYP: Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy. Circulation 1988;78:980-993.
    • (1988) Circulation , vol.78 , pp. 980-993
    • Thomas, J.D.1    Wilkins, G.T.2    Choong, C.Y.P.3
  • 8
    • 0023235804 scopus 로고
    • Effect of aortic regurgitation on the assessment of mitral orifice area by Doppler pressure half-time in mitral stenosis
    • Grayburn PA, Smith MD, Gurley JC: Effect of aortic regurgitation on the assessment of mitral orifice area by Doppler pressure half-time in mitral stenosis. Am J Cardiol 1987;60:322-326.
    • (1987) Am J Cardiol , vol.60 , pp. 322-326
    • Grayburn, P.A.1    Smith, M.D.2    Gurley, J.C.3
  • 9
    • 0023698346 scopus 로고
    • Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mapping
    • Sahn DJ: Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mapping. J Am Coll Cardiol 1988;12:1354-1365.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 1354-1365
    • Sahn, D.J.1
  • 10
    • 0021847754 scopus 로고
    • Doppler echocardiography: Theory, instrumentation, technique, and application
    • Nishimura RA, Miller FA, Gallahan MJ. Doppler echocardiography: theory, instrumentation, technique, and application. Mayo Clin Proc 1985;60:321-343.
    • (1985) Mayo Clin Proc , vol.60 , pp. 321-343
    • Nishimura, R.A.1    Miller, F.A.2    Gallahan, M.J.3
  • 11
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease: Technique, indications and interpretations in 700 cases
    • Seller RD, Levy MJ. Left retrograde cardioangiography in acquired cardiac disease: Technique, indications and interpretations in 700 cases. Am J Cardiol 1964;14:437.
    • (1964) Am J Cardiol , vol.14 , pp. 437
    • Seller, R.D.1    Levy, M.J.2
  • 12
    • 0029097505 scopus 로고
    • Comparison of proximal isovelocity surface area method with pressure half-time and planimetry in evaluation of mitral stenosis
    • Rifkin RD, Harper K, Tighe DD: Comparison of proximal isovelocity surface area method with pressure half-time and planimetry in evaluation of mitral stenosis. J Am Coll Cardiol 1995;26:458-465.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 458-465
    • Rifkin, R.D.1    Harper, K.2    Tighe, D.D.3
  • 13
    • 0026069172 scopus 로고
    • A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice, an in vitro study
    • Franco Recusani, Bargiggia GS: A new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice, an in vitro study. Circulation 1991;83:594-604.
    • (1991) Circulation , vol.83 , pp. 594-604
    • Recusani, F.1    Bargiggia, G.S.2
  • 14
    • 0027254652 scopus 로고
    • Validation of the proximal flow convergence method
    • Rodriguez L, Thomas JD, Montorroso V: Validation of the proximal flow convergence method. Circulation 1993;88:1157-1165.
    • (1993) Circulation , vol.88 , pp. 1157-1165
    • Rodriguez, L.1    Thomas, J.D.2    Montorroso, V.3
  • 15
    • 0028831935 scopus 로고
    • Color flow Doppler determination of transmitral flow and orifice in mi-tral stenosis: Experimental evaluation of the proximal flow convergence method
    • Shiota T, Jones M, Valdes-Cruz LM: Color flow Doppler determination of transmitral flow and orifice in mi-tral stenosis: experimental evaluation of the proximal flow convergence method. Am Heart J 1995;129:114-123.
    • (1995) Am Heart J , vol.129 , pp. 114-123
    • Shiota, T.1    Jones, M.2    Valdes-Cruz, L.M.3
  • 16
    • 0030028355 scopus 로고    scopus 로고
    • Current status of flow convergence for clinical applications: Is it a leaning tower of "PISA"?
    • Simpson IA, Shiota T, Gharib M: Current status of flow convergence for clinical applications: Is it a leaning tower of "PISA"? J Am Coll Cardiol 1996;27:504-509.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 504-509
    • Simpson, I.A.1    Shiota, T.2    Gharib, M.3
  • 17
    • 0031440352 scopus 로고    scopus 로고
    • Calculation of mitral valve area in mitral stenosis using the proximal isovelocity surface area method
    • Oku K, Utsunomiya T, Mori H: Calculation of mitral valve area in mitral stenosis using the proximal isovelocity surface area method. Jpn Heart J 1997;38:811-819.
    • (1997) Jpn Heart J , vol.38 , pp. 811-819
    • Oku, K.1    Utsunomiya, T.2    Mori, H.3
  • 18
    • 0029400922 scopus 로고
    • Estimation of volume flow rate by surface integration of velocity vectors from color Doppler images
    • Sun Y, Ask P, Sjoberg BJ: Estimation of volume flow rate by surface integration of velocity vectors from color Doppler images. J Am Soc Echocardiogr 1995;8:904-914.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 904-914
    • Sun, Y.1    Ask, P.2    Sjoberg, B.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.