메뉴 건너뛰기




Volumn 111, Issue 2, 2004, Pages 325-331

Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eye

Author keywords

[No Author keywords available]

Indexed keywords

PILOCARPINE;

EID: 0842310439     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2003.05.013     Document Type: Article
Times cited : (79)

References (12)
  • 1
    • 0027967654 scopus 로고
    • The socioeconomic aspects of laser refractive surgery
    • Javitt J.C., Chiang Y.P. The socioeconomic aspects of laser refractive surgery. Arch Ophthalmol. 112:1994;1526-1530.
    • (1994) Arch Ophthalmol , vol.112 , pp. 1526-1530
    • Javitt, J.C.1    Chiang, Y.P.2
  • 2
    • 0031840911 scopus 로고    scopus 로고
    • Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia
    • Rosen E., Gore C. Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia. J Cataract Refract Surg. 24:1998;596-606.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 596-606
    • Rosen, E.1    Gore, C.2
  • 3
    • 0029940224 scopus 로고    scopus 로고
    • Collamer intraocular contact lens to correct high myopia
    • Assetto V., Benedetti S., Pesando P. Collamer intraocular contact lens to correct high myopia. J Cataract Refract Surg. 22:1996;551-556.
    • (1996) J Cataract Refract Surg , vol.22 , pp. 551-556
    • Assetto, V.1    Benedetti, S.2    Pesando, P.3
  • 4
    • 0031763250 scopus 로고    scopus 로고
    • Cataract formation after posterior chamber phakic intraocular lens implantation
    • Trinidade F., Pereira F. Cataract formation after posterior chamber phakic intraocular lens implantation. J Cataract Refract Surg. 24:1998;1661-1663.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1661-1663
    • Trinidade, F.1    Pereira, F.2
  • 5
    • 0022909769 scopus 로고
    • Ophthalmic laser interferometry
    • Fercher A.F., Roth E. Ophthalmic laser interferometry. Proc SPIE. 658:1986;48-51.
    • (1986) Proc SPIE , vol.658 , pp. 48-51
    • Fercher, A.F.1    Roth, E.2
  • 6
    • 84975538971 scopus 로고
    • Eye length measurement by interferometry with partially coherent light
    • Fercher A.F., Mengedoht K., Werner W. Eye length measurement by interferometry with partially coherent light. Opt Lett. 13:1988;186-188.
    • (1988) Opt Lett , vol.13 , pp. 186-188
    • Fercher, A.F.1    Mengedoht, K.2    Werner, W.3
  • 7
    • 0026101781 scopus 로고
    • Optical measurement of the axial eye length by laser Doppler interferometry
    • Hitzenberger C.K. Optical measurement of the axial eye length by laser Doppler interferometry. Invest Ophthalmol Vis Sci. 32:1991;616-624.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 8
    • 0030979884 scopus 로고    scopus 로고
    • Submicrometer precision biometry of the anterior segment of the human eye
    • Drexler W., Baumgartner A., Findl O., et al. Submicrometer precision biometry of the anterior segment of the human eye. Invest Ophthalmol Vis Sci. 38:1997;1304-1313.
    • (1997) Invest Ophthalmol Vis Sci , vol.38 , pp. 1304-1313
    • Drexler, W.1    Baumgartner, A.2    Findl, O.3
  • 9
    • 0030863198 scopus 로고    scopus 로고
    • Biometric investigation of changes in the anterior eye segment during accommodation
    • Drexler W., Baumgartner A., Findl O., et al. Biometric investigation of changes in the anterior eye segment during accommodation. Vision Res. 37:1997;2789-2800.
    • (1997) Vision Res , vol.37 , pp. 2789-2800
    • Drexler, W.1    Baumgartner, A.2    Findl, O.3
  • 10
    • 0031689211 scopus 로고    scopus 로고
    • Eye elongation during accommodation in humans: Differences between emmetropes and myopes
    • Drexler W., Findl O., Schmetterer L., et al. Eye elongation during accommodation in humans differences between emmetropes and myopes . Invest Ophthalmol Vis Sci. 39:1998;2140-2147.
    • (1998) Invest Ophthalmol Vis Sci , vol.39 , pp. 2140-2147
    • Drexler, W.1    Findl, O.2    Schmetterer, L.3
  • 11
    • 0017107514 scopus 로고
    • Effect of pilocarpine on visual acuity and on the dimensions of the cornea and anterior chamber
    • Poinoosawmy D., Nagasubramanian S., Brown N.A. Effect of pilocarpine on visual acuity and on the dimensions of the cornea and anterior chamber. Br J Ophthalmol. 60:1976;676-679.
    • (1976) Br J Ophthalmol , vol.60 , pp. 676-679
    • Poinoosawmy, D.1    Nagasubramanian, S.2    Brown, N.A.3
  • 12
    • 0031915674 scopus 로고    scopus 로고
    • Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry
    • Drexler W., Hitzenberger C.K., Baumgartner A., et al. Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry. Exp Eye Res. 66:1998;25-33.
    • (1998) Exp Eye Res , vol.66 , pp. 25-33
    • Drexler, W.1    Hitzenberger, C.K.2    Baumgartner, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.